Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses

Xenogenic leaflet material, bovine and porcine pericardium, is widely used for the fabrication of surgically implanted and transcatheter heart valve prostheses. As a biological material, long term durability of pericardium is limited due to calcification, degeneration and homogeneity. Therefore, pol...

Full description

Bibliographic Details
Main Authors: Arbeiter Daniela, Brandt-Wunderlich Christoph, Siewert Stefan, Kohse Stefanie, Pfensig Sylvia, Schmitz Klaus-Peter, Grabow Niels
Format: Article
Language:English
Published: De Gruyter 2017-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2017-0149
_version_ 1797848687882272768
author Arbeiter Daniela
Brandt-Wunderlich Christoph
Siewert Stefan
Kohse Stefanie
Pfensig Sylvia
Schmitz Klaus-Peter
Grabow Niels
author_facet Arbeiter Daniela
Brandt-Wunderlich Christoph
Siewert Stefan
Kohse Stefanie
Pfensig Sylvia
Schmitz Klaus-Peter
Grabow Niels
author_sort Arbeiter Daniela
collection DOAJ
description Xenogenic leaflet material, bovine and porcine pericardium, is widely used for the fabrication of surgically implanted and transcatheter heart valve prostheses. As a biological material, long term durability of pericardium is limited due to calcification, degeneration and homogeneity. Therefore, polymeric materials represent a promising approach for a next generation of artificial heart valve leaflets with improved durability. Within the current study we analyzed the mechanical performance of polymeric structures based on elastomeric materials. Polymeric cast films were prepared and nonwovens were manufactured in an electrospinning process. Analysis of cyclic stress-strain behavior was performed, using a universal testing machine. The uniaxial cyclic tensile experiments of the elastomeric samples yielded a non-linear elastic response due to viscoelastic behavior with hysteresis. Equilibrium of stress-strain curves was found after a specific number of cycles, for cast films and nonwovens, respectively. In conclusion, preconditioning was found obligatory for the evaluation of the mechanical performance of polymeric materials for the use as artificial leaflet material for heart valve prostheses.
first_indexed 2024-04-09T18:32:40Z
format Article
id doaj.art-1592c960e7e6407a86e9b92de2ed2250
institution Directory Open Access Journal
issn 2364-5504
language English
last_indexed 2024-04-09T18:32:40Z
publishDate 2017-09-01
publisher De Gruyter
record_format Article
series Current Directions in Biomedical Engineering
spelling doaj.art-1592c960e7e6407a86e9b92de2ed22502023-04-11T17:07:14ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042017-09-013270370610.1515/cdbme-2017-0149cdbme-2017-0149Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prosthesesArbeiter Daniela0Brandt-Wunderlich Christoph1Siewert Stefan2Kohse Stefanie3Pfensig Sylvia4Schmitz Klaus-Peter5Grabow Niels6Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyInstitute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyInstitute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyInstitute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyInstitute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde, GermanyXenogenic leaflet material, bovine and porcine pericardium, is widely used for the fabrication of surgically implanted and transcatheter heart valve prostheses. As a biological material, long term durability of pericardium is limited due to calcification, degeneration and homogeneity. Therefore, polymeric materials represent a promising approach for a next generation of artificial heart valve leaflets with improved durability. Within the current study we analyzed the mechanical performance of polymeric structures based on elastomeric materials. Polymeric cast films were prepared and nonwovens were manufactured in an electrospinning process. Analysis of cyclic stress-strain behavior was performed, using a universal testing machine. The uniaxial cyclic tensile experiments of the elastomeric samples yielded a non-linear elastic response due to viscoelastic behavior with hysteresis. Equilibrium of stress-strain curves was found after a specific number of cycles, for cast films and nonwovens, respectively. In conclusion, preconditioning was found obligatory for the evaluation of the mechanical performance of polymeric materials for the use as artificial leaflet material for heart valve prostheses.https://doi.org/10.1515/cdbme-2017-0149cyclic tensile teststhermoplastic silicone-based polyurethanetranscatheter heart valve prostheses
spellingShingle Arbeiter Daniela
Brandt-Wunderlich Christoph
Siewert Stefan
Kohse Stefanie
Pfensig Sylvia
Schmitz Klaus-Peter
Grabow Niels
Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
Current Directions in Biomedical Engineering
cyclic tensile tests
thermoplastic silicone-based polyurethane
transcatheter heart valve prostheses
title Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
title_full Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
title_fullStr Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
title_full_unstemmed Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
title_short Cyclic stress-strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
title_sort cyclic stress strain behavior of polymeric nonwoven structures for the use as artificial leaflet material for transcatheter heart valve prostheses
topic cyclic tensile tests
thermoplastic silicone-based polyurethane
transcatheter heart valve prostheses
url https://doi.org/10.1515/cdbme-2017-0149
work_keys_str_mv AT arbeiterdaniela cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses
AT brandtwunderlichchristoph cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses
AT siewertstefan cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses
AT kohsestefanie cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses
AT pfensigsylvia cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses
AT schmitzklauspeter cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses
AT grabowniels cyclicstressstrainbehaviorofpolymericnonwovenstructuresfortheuseasartificialleafletmaterialfortranscatheterheartvalveprostheses