Cyclic behavior of non-seismically designed interior reinforced concrete beam-column connections

This paper presents a test of non-seismically detailed reinforced concrete beam-column connections under reversedcyclic load. The tested specimens represented those of the actual mid-rise reinforced concrete frame buildings, designedaccording to the non-seismic provisions of the ACI building code. T...

Full description

Bibliographic Details
Main Authors: Amorn Pimanmas, Teeraphot Supaviriyakit2
Format: Article
Language:English
Published: Prince of Songkla University 2008-05-01
Series:Songklanakarin Journal of Science and Technology (SJST)
Subjects:
Online Access:http://rdo.psu.ac.th/sjst/ejournal/journal/30-3/0125-3395-30-3-323-332.pdf
Description
Summary:This paper presents a test of non-seismically detailed reinforced concrete beam-column connections under reversedcyclic load. The tested specimens represented those of the actual mid-rise reinforced concrete frame buildings, designedaccording to the non-seismic provisions of the ACI building code. The evaluation of 10 existing reinforced concrete frameswas conducted to identify key structural and geometrical indices. It was found that there existed correlation VS structuraland geometrical characteristics and the column tributary area. Hence, the column tributary area was chosen as a parameterfor classifying the specimens. The test results showed that specimens representing small and medium column tributary areafailed by brittle joint shear, while specimen representing large column tributary area failed by ductile flexure, even thoughno ductile seismic details were provided.
ISSN:0125-3395