Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load

As a kind of equipment commonly applied in laboratory vibration test simulation, the shaker has been widely used in many important fields of scientific research on experimental engineering vibration. It is employed for the numerical simulation of seismic activities of large buildings to quickly and...

Full description

Bibliographic Details
Main Authors: Tao Wang, Jinchun Song
Format: Article
Language:English
Published: Hindawi Limited 2023-01-01
Series:Shock and Vibration
Online Access:http://dx.doi.org/10.1155/2023/6273983
_version_ 1797782115380625408
author Tao Wang
Jinchun Song
author_facet Tao Wang
Jinchun Song
author_sort Tao Wang
collection DOAJ
description As a kind of equipment commonly applied in laboratory vibration test simulation, the shaker has been widely used in many important fields of scientific research on experimental engineering vibration. It is employed for the numerical simulation of seismic activities of large buildings to quickly and quantitatively detect and calculate building components related to different building forces, analyze and study various changes of on-site structural forms and the influence mechanism of common earthquake damages or deformations with the actual existence of large-scale seismic activities, as well as to test the antiseismic strengthening structure of buildings to reduce the impact of destructive earthquakes on buildings losses. In general, the load of the shaker is regarded as a rigid structure. But in terms of the load of an electrohydraulic servo shaker with a flexible structure, the system control tends to be nonlinear accompanied by the output signals distorted. In order to achieve the goal of improving the waveform accuracy of shaking tables, it is necessary to combine the corresponding control algorithm strategy. Hence, in compliance with the working principles and functions of shaking table systems, the reasons for the coupling between flexible structure loads and shaking tables are carefully analyzed in this paper. Meanwhile, a control strategy based on the Luenberger observer control method is proposed to effectively realize the coupling suppression within the system and make the output signals of the shaking table reach the required accuracy. Finally, by comparing the frequency characteristic curves of the system before and after the introduction of the Luenberger observer, as well as the output and input analog signals, it can be seen that the Luenberger observer can effectively suppress the impact of oscillations within the system and reproduce the accuracy of the input signals.
first_indexed 2024-03-13T00:06:28Z
format Article
id doaj.art-161ceab638a94e4fa4dda8706e9f2d7a
institution Directory Open Access Journal
issn 1875-9203
language English
last_indexed 2024-03-13T00:06:28Z
publishDate 2023-01-01
publisher Hindawi Limited
record_format Article
series Shock and Vibration
spelling doaj.art-161ceab638a94e4fa4dda8706e9f2d7a2023-07-13T00:00:01ZengHindawi LimitedShock and Vibration1875-92032023-01-01202310.1155/2023/6273983Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure LoadTao Wang0Jinchun Song1School of Mechanical EngineeringSchool of Mechanical Engineering and AutomationAs a kind of equipment commonly applied in laboratory vibration test simulation, the shaker has been widely used in many important fields of scientific research on experimental engineering vibration. It is employed for the numerical simulation of seismic activities of large buildings to quickly and quantitatively detect and calculate building components related to different building forces, analyze and study various changes of on-site structural forms and the influence mechanism of common earthquake damages or deformations with the actual existence of large-scale seismic activities, as well as to test the antiseismic strengthening structure of buildings to reduce the impact of destructive earthquakes on buildings losses. In general, the load of the shaker is regarded as a rigid structure. But in terms of the load of an electrohydraulic servo shaker with a flexible structure, the system control tends to be nonlinear accompanied by the output signals distorted. In order to achieve the goal of improving the waveform accuracy of shaking tables, it is necessary to combine the corresponding control algorithm strategy. Hence, in compliance with the working principles and functions of shaking table systems, the reasons for the coupling between flexible structure loads and shaking tables are carefully analyzed in this paper. Meanwhile, a control strategy based on the Luenberger observer control method is proposed to effectively realize the coupling suppression within the system and make the output signals of the shaking table reach the required accuracy. Finally, by comparing the frequency characteristic curves of the system before and after the introduction of the Luenberger observer, as well as the output and input analog signals, it can be seen that the Luenberger observer can effectively suppress the impact of oscillations within the system and reproduce the accuracy of the input signals.http://dx.doi.org/10.1155/2023/6273983
spellingShingle Tao Wang
Jinchun Song
Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load
Shock and Vibration
title Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load
title_full Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load
title_fullStr Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load
title_full_unstemmed Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load
title_short Electrohydraulic Servo Shaker Control Based on the Single Layer Flexible Structure Load
title_sort electrohydraulic servo shaker control based on the single layer flexible structure load
url http://dx.doi.org/10.1155/2023/6273983
work_keys_str_mv AT taowang electrohydraulicservoshakercontrolbasedonthesinglelayerflexiblestructureload
AT jinchunsong electrohydraulicservoshakercontrolbasedonthesinglelayerflexiblestructureload