BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE

Stripping analysis was proposed for the voltammetric determination of trace cadmium and lead in local rice wine alcoholic beverages. A bismuth-antimony film electrode (Bi-SbFE) was employed for accumulative preconcentration of trace metals by adding 4 mg L−1 of bismuth and 1 mg L−1 of antimony direc...

Full description

Bibliographic Details
Main Authors: Watsaka Siriangkhawut, Kraingkrai Ponhong, Piyanete Chantiratikul, Parita Mayotha
Format: Article
Language:English
Published: Sociedade Brasileira de Química 2023-08-01
Series:Química Nova
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422023000700718&lng=en&tlng=en
_version_ 1797733672427716608
author Watsaka Siriangkhawut
Kraingkrai Ponhong
Piyanete Chantiratikul
Parita Mayotha
author_facet Watsaka Siriangkhawut
Kraingkrai Ponhong
Piyanete Chantiratikul
Parita Mayotha
author_sort Watsaka Siriangkhawut
collection DOAJ
description Stripping analysis was proposed for the voltammetric determination of trace cadmium and lead in local rice wine alcoholic beverages. A bismuth-antimony film electrode (Bi-SbFE) was employed for accumulative preconcentration of trace metals by adding 4 mg L−1 of bismuth and 1 mg L−1 of antimony directly to the sample solution and simultaneously depositing bismuth, antimony, and trace cadmium and lead target metals on the glassy carbon electrode by applying a fixed potential of –1.1 V versus the Ag/AgCl reference electrode for 300 s. Pre-treatment parameters for mineralization of the sample were optimized using the wet acid digestion procedure. Under the optimum conditions, linear calibration graphs ranging 20-200 μg L−1 for Cd and Pb were obtained with detection limits of 0.22 and 0.62 μg L−1 and limits of quantitation 0.73 and 2.07 μg L−1, respectively. Reproducibility values for seven replicate analyses of 50 μg L−1 Cd and Pb were 3.6 and 3.3%, respectively. The developed method was successful for Cd and Pb analyses in Thai rice wine samples and results were validated by the flame atomic absorption spectrometric method. Most samples were not contaminated with Cd and Pb. The amount of Cd contaminants in only one of rice wine sample was still lower than the maximum permitted level of Cd in wine.
first_indexed 2024-03-12T12:31:18Z
format Article
id doaj.art-161d0fa296664400aa5aa127d21e1a5a
institution Directory Open Access Journal
issn 1678-7064
language English
last_indexed 2024-03-12T12:31:18Z
publishDate 2023-08-01
publisher Sociedade Brasileira de Química
record_format Article
series Química Nova
spelling doaj.art-161d0fa296664400aa5aa127d21e1a5a2023-08-29T07:46:11ZengSociedade Brasileira de QuímicaQuímica Nova1678-70642023-08-0146771872310.21577/0100-4042.20230043BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINEWatsaka Siriangkhawuthttps://orcid.org/0000-0002-2409-7965Kraingkrai PonhongPiyanete ChantiratikulParita MayothaStripping analysis was proposed for the voltammetric determination of trace cadmium and lead in local rice wine alcoholic beverages. A bismuth-antimony film electrode (Bi-SbFE) was employed for accumulative preconcentration of trace metals by adding 4 mg L−1 of bismuth and 1 mg L−1 of antimony directly to the sample solution and simultaneously depositing bismuth, antimony, and trace cadmium and lead target metals on the glassy carbon electrode by applying a fixed potential of –1.1 V versus the Ag/AgCl reference electrode for 300 s. Pre-treatment parameters for mineralization of the sample were optimized using the wet acid digestion procedure. Under the optimum conditions, linear calibration graphs ranging 20-200 μg L−1 for Cd and Pb were obtained with detection limits of 0.22 and 0.62 μg L−1 and limits of quantitation 0.73 and 2.07 μg L−1, respectively. Reproducibility values for seven replicate analyses of 50 μg L−1 Cd and Pb were 3.6 and 3.3%, respectively. The developed method was successful for Cd and Pb analyses in Thai rice wine samples and results were validated by the flame atomic absorption spectrometric method. Most samples were not contaminated with Cd and Pb. The amount of Cd contaminants in only one of rice wine sample was still lower than the maximum permitted level of Cd in wine.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422023000700718&lng=en&tlng=enstripping voltammetrybismuth-antimony film electrodecadmiumleadrice wine
spellingShingle Watsaka Siriangkhawut
Kraingkrai Ponhong
Piyanete Chantiratikul
Parita Mayotha
BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
Química Nova
stripping voltammetry
bismuth-antimony film electrode
cadmium
lead
rice wine
title BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
title_full BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
title_fullStr BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
title_full_unstemmed BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
title_short BISMUTH-ANTIMONY FILM ELECTRODE FOR STRIPPING VOLTAMMETRIC DETERMINATION OF TRACE CADMIUM AND LEAD IN THAI RICE WINE
title_sort bismuth antimony film electrode for stripping voltammetric determination of trace cadmium and lead in thai rice wine
topic stripping voltammetry
bismuth-antimony film electrode
cadmium
lead
rice wine
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422023000700718&lng=en&tlng=en
work_keys_str_mv AT watsakasiriangkhawut bismuthantimonyfilmelectrodeforstrippingvoltammetricdeterminationoftracecadmiumandleadinthairicewine
AT kraingkraiponhong bismuthantimonyfilmelectrodeforstrippingvoltammetricdeterminationoftracecadmiumandleadinthairicewine
AT piyanetechantiratikul bismuthantimonyfilmelectrodeforstrippingvoltammetricdeterminationoftracecadmiumandleadinthairicewine
AT paritamayotha bismuthantimonyfilmelectrodeforstrippingvoltammetricdeterminationoftracecadmiumandleadinthairicewine