Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran

Background: Fire safety is one of the most important issues in high-rise buildings. The purpose of this study is to assess maximum possible loss in the fire in Central Insurance Building of Islamic Republic of Iran using the layer of protection analysis (LOPA) method. Method: In 2017, this analytica...

Full description

Bibliographic Details
Main Authors: Mohsen Amini, Ahmad Soltanzadeh, Samira Ghiyasi, Hadi Najafiyan
Format: Article
Language:English
Published: Shahid Sadoughi University of Medical Science, Yazd, Iran 2022-07-01
Series:Archives of Occupational Health
Subjects:
Online Access:http://aoh.ssu.ac.ir/article-1-320-en.pdf
_version_ 1797311427265953792
author Mohsen Amini
Ahmad Soltanzadeh
Samira Ghiyasi
Hadi Najafiyan
author_facet Mohsen Amini
Ahmad Soltanzadeh
Samira Ghiyasi
Hadi Najafiyan
author_sort Mohsen Amini
collection DOAJ
description Background: Fire safety is one of the most important issues in high-rise buildings. The purpose of this study is to assess maximum possible loss in the fire in Central Insurance Building of Islamic Republic of Iran using the layer of protection analysis (LOPA) method. Method: In 2017, this analytical study was conducted on the 21-floor building of the Central Insurance in Iran. To identify the hazard sources and assess the maximum possible loss, the authors used the preliminary hazard list (PHL) and layer of protection analysis (LOPA) respectively. In addition, the analysis of the study data was performed based on the 10×10 risk assessment matrix. Results: The results of the PHL showed that 26 hazardous conditions and four major sources including structural engineering, fire alarm systems and fire extinguishers, design and maintenance of building safety, and behavioral habits were identified as main hazards of fire in the studied building. The application of the LOPA method showed that highest risk level was associated with the fire caused by the exhaust heat from the engine room (RL=48) and the emergency power generator diesel (RL=40), respectively. Conclusion: The findings of this study indicated that calculating the maximum possible loss in the fire of high-rise buildings can help to increase the safety factor. Moreover, the use of the two methods, PHL and LOPA, can be useful in these types of risk assessments.
first_indexed 2024-03-08T01:58:30Z
format Article
id doaj.art-164059b08b014109b638a3b46e807394
institution Directory Open Access Journal
issn 2588-3070
2588-3690
language English
last_indexed 2024-03-08T01:58:30Z
publishDate 2022-07-01
publisher Shahid Sadoughi University of Medical Science, Yazd, Iran
record_format Article
series Archives of Occupational Health
spelling doaj.art-164059b08b014109b638a3b46e8073942024-02-14T06:43:57ZengShahid Sadoughi University of Medical Science, Yazd, IranArchives of Occupational Health2588-30702588-36902022-07-016312811287Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of IranMohsen Amini0Ahmad Soltanzadeh1Samira Ghiyasi2Hadi Najafiyan3 Department of Environmental Engineering, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran Department of Occupational Health and Safety Engineering, Faculty of Health, Qom University of Medical Sciences, Qom, Iran Department of Environmental Engineering, Engineering Faculty, Central Tehran Branch, Islamic Azad University, Tehran, Iran Department of Industrial Management, Management Faculty. Arak Branch, Islamic Azad University, Arak. Iran Background: Fire safety is one of the most important issues in high-rise buildings. The purpose of this study is to assess maximum possible loss in the fire in Central Insurance Building of Islamic Republic of Iran using the layer of protection analysis (LOPA) method. Method: In 2017, this analytical study was conducted on the 21-floor building of the Central Insurance in Iran. To identify the hazard sources and assess the maximum possible loss, the authors used the preliminary hazard list (PHL) and layer of protection analysis (LOPA) respectively. In addition, the analysis of the study data was performed based on the 10×10 risk assessment matrix. Results: The results of the PHL showed that 26 hazardous conditions and four major sources including structural engineering, fire alarm systems and fire extinguishers, design and maintenance of building safety, and behavioral habits were identified as main hazards of fire in the studied building. The application of the LOPA method showed that highest risk level was associated with the fire caused by the exhaust heat from the engine room (RL=48) and the emergency power generator diesel (RL=40), respectively. Conclusion: The findings of this study indicated that calculating the maximum possible loss in the fire of high-rise buildings can help to increase the safety factor. Moreover, the use of the two methods, PHL and LOPA, can be useful in these types of risk assessments.http://aoh.ssu.ac.ir/article-1-320-en.pdfsafetyfiresrisk assessment
spellingShingle Mohsen Amini
Ahmad Soltanzadeh
Samira Ghiyasi
Hadi Najafiyan
Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran
Archives of Occupational Health
safety
fires
risk assessment
title Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran
title_full Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran
title_fullStr Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran
title_full_unstemmed Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran
title_short Assessment of Maximum Possible Loss Caused by Fire in High-Rise Buildings Using the LOPA Method: A Case Study on Central Insurance Building of Iran
title_sort assessment of maximum possible loss caused by fire in high rise buildings using the lopa method a case study on central insurance building of iran
topic safety
fires
risk assessment
url http://aoh.ssu.ac.ir/article-1-320-en.pdf
work_keys_str_mv AT mohsenamini assessmentofmaximumpossiblelosscausedbyfireinhighrisebuildingsusingthelopamethodacasestudyoncentralinsurancebuildingofiran
AT ahmadsoltanzadeh assessmentofmaximumpossiblelosscausedbyfireinhighrisebuildingsusingthelopamethodacasestudyoncentralinsurancebuildingofiran
AT samiraghiyasi assessmentofmaximumpossiblelosscausedbyfireinhighrisebuildingsusingthelopamethodacasestudyoncentralinsurancebuildingofiran
AT hadinajafiyan assessmentofmaximumpossiblelosscausedbyfireinhighrisebuildingsusingthelopamethodacasestudyoncentralinsurancebuildingofiran