Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System

This study aimed to evaluate the egress safety in nursing hospitals based on the capacity of the smoke exhaust system. To this end, the available safe egress time was calculated by analyzing changes in visibility, carbon monoxide, carbon dioxide, oxygen contents, and temperature depending on the fir...

Full description

Bibliographic Details
Main Authors: Seung-Ho Choi, Khaliunaa Darkhanbat, Inwook Heo, Kang Su Kim
Format: Article
Language:English
Published: MDPI AG 2022-08-01
Series:Fire
Subjects:
Online Access:https://www.mdpi.com/2571-6255/5/4/120
_version_ 1797410336120242176
author Seung-Ho Choi
Khaliunaa Darkhanbat
Inwook Heo
Kang Su Kim
author_facet Seung-Ho Choi
Khaliunaa Darkhanbat
Inwook Heo
Kang Su Kim
author_sort Seung-Ho Choi
collection DOAJ
description This study aimed to evaluate the egress safety in nursing hospitals based on the capacity of the smoke exhaust system. To this end, the available safe egress time was calculated by analyzing changes in visibility, carbon monoxide, carbon dioxide, oxygen contents, and temperature depending on the fire duration. In addition, an egress simulation was performed using the number of workers (egress guides) and egress delay time as variables, and the required safe egress time was estimated. Based on the results, the egress safety of a prototype nursing hospital was evaluated. In this study, egress safety criteria to evaluate egress safety in a typical nursing hospital were presented, which are expressed in terms of normalized egress guides, the capacity ratio of the smoke exhaust system, and egress delay time. The proposed criteria can be used to evaluate the egress safety of typical nursing hospitals and to prepare complementary measures.
first_indexed 2024-03-09T04:28:26Z
format Article
id doaj.art-169923ca3ba64b34a073322d8dc6e55e
institution Directory Open Access Journal
issn 2571-6255
language English
last_indexed 2024-03-09T04:28:26Z
publishDate 2022-08-01
publisher MDPI AG
record_format Article
series Fire
spelling doaj.art-169923ca3ba64b34a073322d8dc6e55e2023-12-03T13:38:26ZengMDPI AGFire2571-62552022-08-015412010.3390/fire5040120Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust SystemSeung-Ho Choi0Khaliunaa Darkhanbat1Inwook Heo2Kang Su Kim3Department of Architectural Engineering, University of Seoul, 163 Seoulsiripdae-ro, Dongdaemun-gu, Seoul 02504, KoreaDepartment of Architectural Engineering and the Smart City Interdisciplinary Major Program, University of Seoul, 163 Seoulsiripdae-ro, Dongdaemun-gu, Seoul 02504, KoreaDepartment of Architectural Engineering, University of Seoul, 163 Seoulsiripdae-ro, Dongdaemun-gu, Seoul 02504, KoreaDepartment of Architectural Engineering and the Smart City Interdisciplinary Major Program, University of Seoul, 163 Seoulsiripdae-ro, Dongdaemun-gu, Seoul 02504, KoreaThis study aimed to evaluate the egress safety in nursing hospitals based on the capacity of the smoke exhaust system. To this end, the available safe egress time was calculated by analyzing changes in visibility, carbon monoxide, carbon dioxide, oxygen contents, and temperature depending on the fire duration. In addition, an egress simulation was performed using the number of workers (egress guides) and egress delay time as variables, and the required safe egress time was estimated. Based on the results, the egress safety of a prototype nursing hospital was evaluated. In this study, egress safety criteria to evaluate egress safety in a typical nursing hospital were presented, which are expressed in terms of normalized egress guides, the capacity ratio of the smoke exhaust system, and egress delay time. The proposed criteria can be used to evaluate the egress safety of typical nursing hospitals and to prepare complementary measures.https://www.mdpi.com/2571-6255/5/4/120egress safety criteriafire dynamic simulator (FDS)nursing hospitalpathfindersmoke exhaust system
spellingShingle Seung-Ho Choi
Khaliunaa Darkhanbat
Inwook Heo
Kang Su Kim
Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System
Fire
egress safety criteria
fire dynamic simulator (FDS)
nursing hospital
pathfinder
smoke exhaust system
title Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System
title_full Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System
title_fullStr Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System
title_full_unstemmed Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System
title_short Evaluation on Egress Safety of Nursing Hospital Considering the Smoke Exhaust System
title_sort evaluation on egress safety of nursing hospital considering the smoke exhaust system
topic egress safety criteria
fire dynamic simulator (FDS)
nursing hospital
pathfinder
smoke exhaust system
url https://www.mdpi.com/2571-6255/5/4/120
work_keys_str_mv AT seunghochoi evaluationonegresssafetyofnursinghospitalconsideringthesmokeexhaustsystem
AT khaliunaadarkhanbat evaluationonegresssafetyofnursinghospitalconsideringthesmokeexhaustsystem
AT inwookheo evaluationonegresssafetyofnursinghospitalconsideringthesmokeexhaustsystem
AT kangsukim evaluationonegresssafetyofnursinghospitalconsideringthesmokeexhaustsystem