Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd
Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.P...
Main Authors: | , |
---|---|
Format: | Article |
Language: | fas |
Published: |
Tehran University of Medical Sciences
2005-02-01
|
Series: | Journal of Dental Medicine |
Subjects: | |
Online Access: | http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4581.pdf&manuscript_id=4581 |
_version_ | 1819138079692161024 |
---|---|
author | D.Goodarzi Pour S.Ebrahimi Moghaddam |
author_facet | D.Goodarzi Pour S.Ebrahimi Moghaddam |
author_sort | D.Goodarzi Pour |
collection | DOAJ |
description | Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market. |
first_indexed | 2024-12-22T11:01:04Z |
format | Article |
id | doaj.art-16a5138e4b774f44a409ee9692aef7cd |
institution | Directory Open Access Journal |
issn | 1024-641X 2008-2444 |
language | fas |
last_indexed | 2024-12-22T11:01:04Z |
publishDate | 2005-02-01 |
publisher | Tehran University of Medical Sciences |
record_format | Article |
series | Journal of Dental Medicine |
spelling | doaj.art-16a5138e4b774f44a409ee9692aef7cd2022-12-21T18:28:29ZfasTehran University of Medical SciencesJournal of Dental Medicine1024-641X2008-24442005-02-011746167Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in YazdD.Goodarzi PourS.Ebrahimi MoghaddamStatement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market.http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4581.pdf&manuscript_id=4581X RayProtectionYazd |
spellingShingle | D.Goodarzi Pour S.Ebrahimi Moghaddam Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd Journal of Dental Medicine X Ray Protection Yazd |
title | Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd |
title_full | Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd |
title_fullStr | Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd |
title_full_unstemmed | Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd |
title_short | Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd |
title_sort | evaluation of x ray protective measurements in intraoral radiography equipped centers in yazd |
topic | X Ray Protection Yazd |
url | http://journals.tums.ac.ir/PdfMed.aspx?pdf_med=/upload_files/pdf/4581.pdf&manuscript_id=4581 |
work_keys_str_mv | AT dgoodarzipour evaluationofxrayprotectivemeasurementsinintraoralradiographyequippedcentersinyazd AT sebrahimimoghaddam evaluationofxrayprotectivemeasurementsinintraoralradiographyequippedcentersinyazd |