In-Laboratory Polysomnography Worsens Obstructive Sleep Apnea by Changing Body Position Compared to Home Testing

(1) Background: Home sleep apnea testing, known as polysomnography type 3 (PSG3), underestimates respiratory events in comparison with in-laboratory polysomnography type 1 (PSG1). Without head electrodes for scoring sleep and arousal, in a home environment, patients feel unfettered and move their bo...

Celý popis

Podrobná bibliografie
Hlavní autoři: Raquel Chartuni Pereira Teixeira, Michel Burihan Cahali
Médium: Článek
Jazyk:English
Vydáno: MDPI AG 2024-04-01
Edice:Sensors
Témata: