<b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
The aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universidade Federal de Santa Catarina
2011-03-01
|
Series: | Revista Brasileira de Cineantropometria e Desempenho Humano |
Subjects: | |
Online Access: | http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947 |
_version_ | 1811312999304003584 |
---|---|
author | Ronei Silveira Pinto Martim Bottaro Eurico Nestor Wilhelm Neto Regis Radaelli |
author_facet | Ronei Silveira Pinto Martim Bottaro Eurico Nestor Wilhelm Neto Regis Radaelli |
author_sort | Ronei Silveira Pinto |
collection | DOAJ |
description | The aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01). There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors. |
first_indexed | 2024-04-13T10:46:31Z |
format | Article |
id | doaj.art-17486e6a847a40ffbc41cced6a6e7956 |
institution | Directory Open Access Journal |
issn | 1415-8426 1980-0037 |
language | English |
last_indexed | 2024-04-13T10:46:31Z |
publishDate | 2011-03-01 |
publisher | Universidade Federal de Santa Catarina |
record_format | Article |
series | Revista Brasileira de Cineantropometria e Desempenho Humano |
spelling | doaj.art-17486e6a847a40ffbc41cced6a6e79562022-12-22T02:49:46ZengUniversidade Federal de Santa CatarinaRevista Brasileira de Cineantropometria e Desempenho Humano1415-84261980-00372011-03-011328793<b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87Ronei Silveira PintoMartim BottaroEurico Nestor Wilhelm NetoRegis RadaelliThe aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01). There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947UltrasonographyMuscle thicknessMuscle qualityMuscle strengthUltrasonografiaEspessura muscularQualidade muscularForça muscular. |
spellingShingle | Ronei Silveira Pinto Martim Bottaro Eurico Nestor Wilhelm Neto Regis Radaelli <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87 Revista Brasileira de Cineantropometria e Desempenho Humano Ultrasonography Muscle thickness Muscle quality Muscle strength Ultrasonografia Espessura muscular Qualidade muscular Força muscular. |
title | <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87 |
title_full | <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87 |
title_fullStr | <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87 |
title_full_unstemmed | <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87 |
title_short | <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87 |
title_sort | b muscle thickness and muscle quality measured by ultrasound influence of different sites of measurement b doi 10 5007 1980 0037 2011v13n2p87 |
topic | Ultrasonography Muscle thickness Muscle quality Muscle strength Ultrasonografia Espessura muscular Qualidade muscular Força muscular. |
url | http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947 |
work_keys_str_mv | AT roneisilveirapinto bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87 AT martimbottaro bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87 AT euriconestorwilhelmneto bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87 AT regisradaelli bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87 |