<b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87

The aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young...

Full description

Bibliographic Details
Main Authors: Ronei Silveira Pinto, Martim Bottaro, Eurico Nestor Wilhelm Neto, Regis Radaelli
Format: Article
Language:English
Published: Universidade Federal de Santa Catarina 2011-03-01
Series:Revista Brasileira de Cineantropometria e Desempenho Humano
Subjects:
Online Access:http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947
_version_ 1811312999304003584
author Ronei Silveira Pinto
Martim Bottaro
Eurico Nestor Wilhelm Neto
Regis Radaelli
author_facet Ronei Silveira Pinto
Martim Bottaro
Eurico Nestor Wilhelm Neto
Regis Radaelli
author_sort Ronei Silveira Pinto
collection DOAJ
description The aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01). There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.
first_indexed 2024-04-13T10:46:31Z
format Article
id doaj.art-17486e6a847a40ffbc41cced6a6e7956
institution Directory Open Access Journal
issn 1415-8426
1980-0037
language English
last_indexed 2024-04-13T10:46:31Z
publishDate 2011-03-01
publisher Universidade Federal de Santa Catarina
record_format Article
series Revista Brasileira de Cineantropometria e Desempenho Humano
spelling doaj.art-17486e6a847a40ffbc41cced6a6e79562022-12-22T02:49:46ZengUniversidade Federal de Santa CatarinaRevista Brasileira de Cineantropometria e Desempenho Humano1415-84261980-00372011-03-011328793<b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87Ronei Silveira PintoMartim BottaroEurico Nestor Wilhelm NetoRegis RadaelliThe aims of this study were: a) to investigate differences in muscle thickness (MT) measured by ultrasound and muscle quality (MQ) at three sites in the elbow flexors and knee extensors, and b) to correlate MT with isometric force production of the elbow flexors and knee extensors. Sixty-nine young male subjects participated in this study. The isometric force production values of the elbow flexors and knee extensors were obtained at 90° and 60°, respectively. MT was assessed at three sites in the elbow flexors (proximal – BB1, middle – BB2, and distal – BB3) and knee extensors (proximal – RI1, middle – RI2, and distal – RI3). Differences between the three measurements of MT and MQ were evaluated by one-way repeated measures ANOVA. Pearson’s correlation test was used to assess the correlation between MT and isometric force. The level of significance was set at p<0.05. The results showed significant differences (p<0.001) between the three MT and MQ sites in the elbow flexors (BB1, BB2, BB3) and in the knee extensors (RI1, RI2, RI3). The correlation between BB1, BB2 and BB3 and force production was r=0.57, r=0.52 and r=0.59, respectively (p<0.05). In the knee extensors, the correlation between RI1, RI2 and RI3 and force production was r=0.47, r=0.51 and r=0.53, respectively (p<0.01). There were significant differences in MQ between elbow flexors (p<0.001) and knee extensors (p<0.001). The present results showed that the site of measurement has a significant influence on MT and MQ. Furthermore, MT was positively correlated with isometric force production in the elbow flexors and knee extensors.http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947UltrasonographyMuscle thicknessMuscle qualityMuscle strengthUltrasonografiaEspessura muscularQualidade muscularForça muscular.
spellingShingle Ronei Silveira Pinto
Martim Bottaro
Eurico Nestor Wilhelm Neto
Regis Radaelli
<b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
Revista Brasileira de Cineantropometria e Desempenho Humano
Ultrasonography
Muscle thickness
Muscle quality
Muscle strength
Ultrasonografia
Espessura muscular
Qualidade muscular
Força muscular.
title <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
title_full <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
title_fullStr <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
title_full_unstemmed <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
title_short <b>Muscle thickness and muscle quality measured by ultrasound: influence of different sites of measurement</b> DOI: 10.5007/1980-0037.2011v13n2p87
title_sort b muscle thickness and muscle quality measured by ultrasound influence of different sites of measurement b doi 10 5007 1980 0037 2011v13n2p87
topic Ultrasonography
Muscle thickness
Muscle quality
Muscle strength
Ultrasonografia
Espessura muscular
Qualidade muscular
Força muscular.
url http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n2p87/16947
work_keys_str_mv AT roneisilveirapinto bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87
AT martimbottaro bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87
AT euriconestorwilhelmneto bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87
AT regisradaelli bmusclethicknessandmusclequalitymeasuredbyultrasoundinfluenceofdifferentsitesofmeasurementbdoi105007198000372011v13n2p87