To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures

Background: Fracture of distal radius may be stable that is extra-articular, non-comminuted without distal radio ulnar joint disruption or unstable that is intra-articular, comminuted displaced with distal radio ulnar joint disruption. Complications of unstable fractures are shortening due to bone l...

Full description

Bibliographic Details
Main Authors: Atul Kumar Saroj, Ashutosh Verma, Mohd. Baqar Abbas, Upendra Kumar Patel, Virendra Kumar
Format: Article
Language:English
Published: Manipal College of Medical Sciences, Pokhara 2023-07-01
Series:Asian Journal of Medical Sciences
Subjects:
Online Access:https://www.nepjol.info/index.php/AJMS/article/view/52056
_version_ 1797790032782688256
author Atul Kumar Saroj
Ashutosh Verma
Mohd. Baqar Abbas
Upendra Kumar Patel
Virendra Kumar
author_facet Atul Kumar Saroj
Ashutosh Verma
Mohd. Baqar Abbas
Upendra Kumar Patel
Virendra Kumar
author_sort Atul Kumar Saroj
collection DOAJ
description Background: Fracture of distal radius may be stable that is extra-articular, non-comminuted without distal radio ulnar joint disruption or unstable that is intra-articular, comminuted displaced with distal radio ulnar joint disruption. Complications of unstable fractures are shortening due to bone loss or due to resorption of the cancellous bone from metaphysis, resistant deformity, residual pain, late collapse, radio carpal arthritis and gross functional impairment. Aims and Objective: The purpose of this study to compare the relative efficacy of external fixation versus plating with regard to functional and radiological outcome. Materials and Methods: Total of 60 patients having intraarticular distal end radius fracture were included in this study and was equally divided into two groups, one group treated by external fixator other group with volar locking compression plate with or without augmentation by k-wire. Follow-up was done after 2 weeks, 4 weeks, 6 weeks and 3 ,6 and 12 months. The radiological evaluation was performed with Sarmiento’s Modification of Lindstrom’s Criteria. With the Modified Mayo Wrist Score, the patient’s functional outcomes were assessed and both groups were compared. Results: In this study we found that volar plate group had good to excellent outcome in 73% cases and 07% with fair outcome however with external fixator group found good to excellent in 50% cases and poor in 17% cases. Conclusion: In our study, we showed that the use of an external fixator and a volar locking plate for the treatment of intraarticular distal radial fractures were reliable. The relative simplicity of use, low surgical exposure, and decreased surgical trauma are benefits of external fixation. Despite these volar locking plates augmented with or without k wire had a good to excellent results in terms of early rehabilitation and less complications related to wrist joint. External fixator with ligamentotaxis provide significant good results in communited intraarticular distal end radius fracture.
first_indexed 2024-03-13T01:59:00Z
format Article
id doaj.art-175183dacc4b4967b4dac6fe7cd580f3
institution Directory Open Access Journal
issn 2467-9100
2091-0576
language English
last_indexed 2024-03-13T01:59:00Z
publishDate 2023-07-01
publisher Manipal College of Medical Sciences, Pokhara
record_format Article
series Asian Journal of Medical Sciences
spelling doaj.art-175183dacc4b4967b4dac6fe7cd580f32023-07-02T07:02:27ZengManipal College of Medical Sciences, PokharaAsian Journal of Medical Sciences2467-91002091-05762023-07-01147245249https://doi.org/10.3126/ajms.v14i7.52056To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fracturesAtul Kumar Saroj 0https://orcid.org/0000-0002-4401-9788Ashutosh Verma 1https://orcid.org/0000-0001-7816-9584Mohd. Baqar Abbas 2https://orcid.org/0000-0003-2673-2763Upendra Kumar Patel 3https://orcid.org/0009-0008-4597-1026Virendra Kumar4https://orcid.org/0009-0002-3962-4737Senior Resident, Department of Orthopaedics, K. G. Medical University, Lucknow, Uttar Pradesh, India Senior Resident, Department of Orthopaedics, K. G. Medical University, Lucknow, Uttar Pradesh, India Assistant Professor, Department of Orthopaedics, J. N. Medical College, Aligarh, Uttar Pradesh, India Junior Resident, Department of Orthopaedics, K. G. Medical University, Lucknow, Uttar Pradesh, India Junior Resident, Department of Orthopaedics, K. G. Medical University, Lucknow, Uttar Pradesh, India Background: Fracture of distal radius may be stable that is extra-articular, non-comminuted without distal radio ulnar joint disruption or unstable that is intra-articular, comminuted displaced with distal radio ulnar joint disruption. Complications of unstable fractures are shortening due to bone loss or due to resorption of the cancellous bone from metaphysis, resistant deformity, residual pain, late collapse, radio carpal arthritis and gross functional impairment. Aims and Objective: The purpose of this study to compare the relative efficacy of external fixation versus plating with regard to functional and radiological outcome. Materials and Methods: Total of 60 patients having intraarticular distal end radius fracture were included in this study and was equally divided into two groups, one group treated by external fixator other group with volar locking compression plate with or without augmentation by k-wire. Follow-up was done after 2 weeks, 4 weeks, 6 weeks and 3 ,6 and 12 months. The radiological evaluation was performed with Sarmiento’s Modification of Lindstrom’s Criteria. With the Modified Mayo Wrist Score, the patient’s functional outcomes were assessed and both groups were compared. Results: In this study we found that volar plate group had good to excellent outcome in 73% cases and 07% with fair outcome however with external fixator group found good to excellent in 50% cases and poor in 17% cases. Conclusion: In our study, we showed that the use of an external fixator and a volar locking plate for the treatment of intraarticular distal radial fractures were reliable. The relative simplicity of use, low surgical exposure, and decreased surgical trauma are benefits of external fixation. Despite these volar locking plates augmented with or without k wire had a good to excellent results in terms of early rehabilitation and less complications related to wrist joint. External fixator with ligamentotaxis provide significant good results in communited intraarticular distal end radius fracture.https://www.nepjol.info/index.php/AJMS/article/view/52056distal end radiusexternal fixatorfracture volar locking compression plate
spellingShingle Atul Kumar Saroj
Ashutosh Verma
Mohd. Baqar Abbas
Upendra Kumar Patel
Virendra Kumar
To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
Asian Journal of Medical Sciences
distal end radius
external fixator
fracture volar locking compression plate
title To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
title_full To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
title_fullStr To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
title_full_unstemmed To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
title_short To compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
title_sort to compare the functional and radiological outcome between external fixation and volar plating for the treatment of intraarticular distal end radius fractures
topic distal end radius
external fixator
fracture volar locking compression plate
url https://www.nepjol.info/index.php/AJMS/article/view/52056
work_keys_str_mv AT atulkumarsaroj tocomparethefunctionalandradiologicaloutcomebetweenexternalfixationandvolarplatingforthetreatmentofintraarticulardistalendradiusfractures
AT ashutoshverma tocomparethefunctionalandradiologicaloutcomebetweenexternalfixationandvolarplatingforthetreatmentofintraarticulardistalendradiusfractures
AT mohdbaqarabbas tocomparethefunctionalandradiologicaloutcomebetweenexternalfixationandvolarplatingforthetreatmentofintraarticulardistalendradiusfractures
AT upendrakumarpatel tocomparethefunctionalandradiologicaloutcomebetweenexternalfixationandvolarplatingforthetreatmentofintraarticulardistalendradiusfractures
AT virendrakumar tocomparethefunctionalandradiologicaloutcomebetweenexternalfixationandvolarplatingforthetreatmentofintraarticulardistalendradiusfractures