Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath

With the increasing number of implanted pacemakers and implantable cardioverter defibrillators, removal is required more frequently. Presently described is the transvenous extraction of a 26-year-old Accufix atrial lead using a mechanical dilator sheath. A 50-year-old male patient was admitted to th...

Full description

Bibliographic Details
Main Authors: Anar Mammadli, Veysel Kutay Vurgun, Onur Yıldırım, Ali Timuçin Altın, Başar Candemir, Ömer Akyürek
Format: Article
Language:English
Published: KARE Publishing 2018-01-01
Series:Türk Kardiyoloji Derneği Arşivi
Subjects:
Online Access:https://jag.journalagent.com/z4/download_fulltext.asp?pdir=tkd&un=TKDA-56239
_version_ 1828024057708150784
author Anar Mammadli
Veysel Kutay Vurgun
Onur Yıldırım
Ali Timuçin Altın
Başar Candemir
Ömer Akyürek
author_facet Anar Mammadli
Veysel Kutay Vurgun
Onur Yıldırım
Ali Timuçin Altın
Başar Candemir
Ömer Akyürek
author_sort Anar Mammadli
collection DOAJ
description With the increasing number of implanted pacemakers and implantable cardioverter defibrillators, removal is required more frequently. Presently described is the transvenous extraction of a 26-year-old Accufix atrial lead using a mechanical dilator sheath. A 50-year-old male patient was admitted to the clinic with a pacemaker pocket infection. The atrial lead was an Accufix Bipolar J-Atrial active fixation lead, a model that was recalled in 1994, after reports of 2 deaths and 2 nonfatal injuries related to protrusion of the J retention wire. Both the atrial and ventricular leads were extracted using a mechanical dilator sheath. The Pacemaker Lead Extraction with the Excimer Sheath (PLEXES) Trial reported that of the 57 Accufix leads randomized to a non-laser approach, only 47% were removed successfully, compared with 96% of laser-randomized cases. Since laser sheaths are not available in Turkey, use of a mechanical dilator sheath was required. To our knowledge, this is the oldest Accufix lead extracted with a non-laser sheath. During the extraction of the ventricular lead, the tip of the lead broke off inside the right ventricle and the residual part was left inside the heart. During 3 months of follow-up, no signs of infection or any other undesirable events were encountered.
first_indexed 2024-04-10T12:38:06Z
format Article
id doaj.art-17d10d5f379840b9b5b2a91a9d48d416
institution Directory Open Access Journal
issn 1016-5169
language English
last_indexed 2024-04-10T12:38:06Z
publishDate 2018-01-01
publisher KARE Publishing
record_format Article
series Türk Kardiyoloji Derneği Arşivi
spelling doaj.art-17d10d5f379840b9b5b2a91a9d48d4162023-02-15T16:14:26ZengKARE PublishingTürk Kardiyoloji Derneği Arşivi1016-51692018-01-01461545610.5543/tkda.2017.56239TKDA-56239Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheathAnar Mammadli0Veysel Kutay Vurgun1Onur Yıldırım2Ali Timuçin Altın3Başar Candemir4Ömer Akyürek5Department of Cardiology, Ankara University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Ankara University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Ankara University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Ankara University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Ankara University Faculty of Medicine, Ankara, TurkeyDepartment of Cardiology, Ankara University Faculty of Medicine, Ankara, TurkeyWith the increasing number of implanted pacemakers and implantable cardioverter defibrillators, removal is required more frequently. Presently described is the transvenous extraction of a 26-year-old Accufix atrial lead using a mechanical dilator sheath. A 50-year-old male patient was admitted to the clinic with a pacemaker pocket infection. The atrial lead was an Accufix Bipolar J-Atrial active fixation lead, a model that was recalled in 1994, after reports of 2 deaths and 2 nonfatal injuries related to protrusion of the J retention wire. Both the atrial and ventricular leads were extracted using a mechanical dilator sheath. The Pacemaker Lead Extraction with the Excimer Sheath (PLEXES) Trial reported that of the 57 Accufix leads randomized to a non-laser approach, only 47% were removed successfully, compared with 96% of laser-randomized cases. Since laser sheaths are not available in Turkey, use of a mechanical dilator sheath was required. To our knowledge, this is the oldest Accufix lead extracted with a non-laser sheath. During the extraction of the ventricular lead, the tip of the lead broke off inside the right ventricle and the residual part was left inside the heart. During 3 months of follow-up, no signs of infection or any other undesirable events were encountered.https://jag.journalagent.com/z4/download_fulltext.asp?pdir=tkd&un=TKDA-56239accufix atrial leadlead extraction; pacemaker pocket infection.
spellingShingle Anar Mammadli
Veysel Kutay Vurgun
Onur Yıldırım
Ali Timuçin Altın
Başar Candemir
Ömer Akyürek
Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
Türk Kardiyoloji Derneği Arşivi
accufix atrial lead
lead extraction; pacemaker pocket infection.
title Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
title_full Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
title_fullStr Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
title_full_unstemmed Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
title_short Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
title_sort transvenous extraction of a 26 year old accufix atrial lead using tightrail rotating dilator sheath
topic accufix atrial lead
lead extraction; pacemaker pocket infection.
url https://jag.journalagent.com/z4/download_fulltext.asp?pdir=tkd&un=TKDA-56239
work_keys_str_mv AT anarmammadli transvenousextractionofa26yearoldaccufixatrialleadusingtightrailrotatingdilatorsheath
AT veyselkutayvurgun transvenousextractionofa26yearoldaccufixatrialleadusingtightrailrotatingdilatorsheath
AT onuryıldırım transvenousextractionofa26yearoldaccufixatrialleadusingtightrailrotatingdilatorsheath
AT alitimucinaltın transvenousextractionofa26yearoldaccufixatrialleadusingtightrailrotatingdilatorsheath
AT basarcandemir transvenousextractionofa26yearoldaccufixatrialleadusingtightrailrotatingdilatorsheath
AT omerakyurek transvenousextractionofa26yearoldaccufixatrialleadusingtightrailrotatingdilatorsheath