Prioritization approach for circuit breakers to equip with condition monitoring devices
Circuit Breakers (CBs) play an important role in ensuring the safe operation of protection systems. Condition Monitoring (CM) devices are widely implemented to extend lifetime, and to improve the maintenance quality. The present paper proposes a cost-based prioritization approach for CBs in a networ...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Academy of Sciences
2020-06-01
|
Series: | Archives of Electrical Engineering |
Subjects: | |
Online Access: | https://journals.pan.pl/dlibra/publication/133034/edition/116234/content |
_version_ | 1818453531196129280 |
---|---|
author | Ali Karimabadi Mohammad Ebrahim Hajiabadi Ebadollah Kamyab |
author_facet | Ali Karimabadi Mohammad Ebrahim Hajiabadi Ebadollah Kamyab |
author_sort | Ali Karimabadi |
collection | DOAJ |
description | Circuit Breakers (CBs) play an important role in ensuring the safe operation of protection systems. Condition Monitoring (CM) devices are widely implemented to extend lifetime, and to improve the maintenance quality. The present paper proposes a cost-based prioritization approach for CBs in a network equipped withCMdevices. To this end, a mathematical formulation is developed for the categorization and modeling of equipment failures based on their severity. This formulation quantifies the effect of the CM devices on the outage rate of the equipment. The reliability parameters of the substations 400/132/20 KV, including the failure rate, , average repair time, r, average outage time, U, substations, in two status of without CM and with CM of the CBs are calculated. These parameters are calculated implementing a minimal cut-set method. The outage rate of equipment with and without the CM devices is used to determine the effect of the CM devices on the reliability of the network. Finally, the prioritization of substations to install theCMdevices on the CBs has been investigated in terms of the Expected Energy Not Supplied (EENS) and costs of CM. To verify the effectiveness and applicability of the method, the proposed approach is applied to the CBs in the power transmission network in the Khorasan Regional Electricity Company (KREC) in Iran. |
first_indexed | 2024-12-14T21:40:28Z |
format | Article |
id | doaj.art-18077f6fed9949709a16d9987e96862f |
institution | Directory Open Access Journal |
issn | 2300-2506 |
language | English |
last_indexed | 2024-12-14T21:40:28Z |
publishDate | 2020-06-01 |
publisher | Polish Academy of Sciences |
record_format | Article |
series | Archives of Electrical Engineering |
spelling | doaj.art-18077f6fed9949709a16d9987e96862f2022-12-21T22:46:28ZengPolish Academy of SciencesArchives of Electrical Engineering2300-25062020-06-0169240342210.24425/aee.2020.133034Prioritization approach for circuit breakers to equip with condition monitoring devicesAli Karimabadi0 Mohammad Ebrahim Hajiabadi1 Ebadollah Kamyab2Fanavaran Energy Toos Company, Mashhad, IranElectrical and Computer Engineering Department, Hakim Sabzevari University, Sabzevar, IranKhorasan Regional Electricity Company (KREC), Mashhad, IranCircuit Breakers (CBs) play an important role in ensuring the safe operation of protection systems. Condition Monitoring (CM) devices are widely implemented to extend lifetime, and to improve the maintenance quality. The present paper proposes a cost-based prioritization approach for CBs in a network equipped withCMdevices. To this end, a mathematical formulation is developed for the categorization and modeling of equipment failures based on their severity. This formulation quantifies the effect of the CM devices on the outage rate of the equipment. The reliability parameters of the substations 400/132/20 KV, including the failure rate, , average repair time, r, average outage time, U, substations, in two status of without CM and with CM of the CBs are calculated. These parameters are calculated implementing a minimal cut-set method. The outage rate of equipment with and without the CM devices is used to determine the effect of the CM devices on the reliability of the network. Finally, the prioritization of substations to install theCMdevices on the CBs has been investigated in terms of the Expected Energy Not Supplied (EENS) and costs of CM. To verify the effectiveness and applicability of the method, the proposed approach is applied to the CBs in the power transmission network in the Khorasan Regional Electricity Company (KREC) in Iran.https://journals.pan.pl/dlibra/publication/133034/edition/116234/contentcircuit breakerscondition monitoringoutage ratereliabilitysmart sensor |
spellingShingle | Ali Karimabadi Mohammad Ebrahim Hajiabadi Ebadollah Kamyab Prioritization approach for circuit breakers to equip with condition monitoring devices Archives of Electrical Engineering circuit breakers condition monitoring outage rate reliability smart sensor |
title | Prioritization approach for circuit breakers to equip with condition monitoring devices |
title_full | Prioritization approach for circuit breakers to equip with condition monitoring devices |
title_fullStr | Prioritization approach for circuit breakers to equip with condition monitoring devices |
title_full_unstemmed | Prioritization approach for circuit breakers to equip with condition monitoring devices |
title_short | Prioritization approach for circuit breakers to equip with condition monitoring devices |
title_sort | prioritization approach for circuit breakers to equip with condition monitoring devices |
topic | circuit breakers condition monitoring outage rate reliability smart sensor |
url | https://journals.pan.pl/dlibra/publication/133034/edition/116234/content |
work_keys_str_mv | AT alikarimabadi prioritizationapproachforcircuitbreakerstoequipwithconditionmonitoringdevices AT mohammadebrahimhajiabadi prioritizationapproachforcircuitbreakerstoequipwithconditionmonitoringdevices AT ebadollahkamyab prioritizationapproachforcircuitbreakerstoequipwithconditionmonitoringdevices |