Temperature properties of passive magnetic bearing

The practical interest in passive magnetic bearings is due to the fact that they are not subject to wear and have insignificant dissipative energy losses. However, when the magnets are heated during operation, a reversible and irreversible decrease in the residual magnetization occurs and, consequen...

Full description

Bibliographic Details
Main Authors: Bolotov Aleksander, Novikova Olga, Novikov Vladislav
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/13/e3sconf_ersme2023_01068.pdf
_version_ 1797850755853451264
author Bolotov Aleksander
Novikova Olga
Novikov Vladislav
author_facet Bolotov Aleksander
Novikova Olga
Novikov Vladislav
author_sort Bolotov Aleksander
collection DOAJ
description The practical interest in passive magnetic bearings is due to the fact that they are not subject to wear and have insignificant dissipative energy losses. However, when the magnets are heated during operation, a reversible and irreversible decrease in the residual magnetization occurs and, consequently, the force of interaction between them changes. The thermal properties of passive magnetic bearings are adversely affected by the large demagnetizing fields from the coupled magnets. To predict the performance of passive magnetic bearings with regard to external temperature, an assessment of temperature changes in the bearing capacity of bearings with optimally shaped magnets is necessary. The optimum magnets were considered to be those with sizes, whose interaction force, reduced to a single volume of magnetic material, was the maximum. A magnetic system of two cylindrical magnets with equal radii and heights located coaxially or with some radial displacement was considered. The studies were carried out on cylindrical magnets made of SmCo5 alloy, capable of maintaining magnetically hard properties at temperatures up to 250°C. It was confirmed that irreversible changes in the magnetic force for bearings with optimally sized magnets are close to each other. The destabilizing (radial) magnetic force at small radial displacements of one of the magnets also irreversibly decreased. A temperature of 250°C defines the upper limit of the temperature range for the normal operation of magnetic bearings with SmCo5 magnets. It was found that as a result of the action of a demagnetizing field on magnets during heating, they develop a significant inhomogeneity of magnetization over the volume. After demagnetization of the magnets kept at a temperature of 260 °C, the force of their interaction reaches only 85 - 90% of the original, which is associated with microstructural changes in the magnets. Theoretically and experimentally, the numerical values of the temperature coefficients of changes in the bearing capacity and stiffness of bearings are determined.
first_indexed 2024-04-09T19:06:37Z
format Article
id doaj.art-187a208739eb4ec991a411e954e3914c
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-04-09T19:06:37Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-187a208739eb4ec991a411e954e3914c2023-04-07T08:57:52ZengEDP SciencesE3S Web of Conferences2267-12422023-01-013760106810.1051/e3sconf/202337601068e3sconf_ersme2023_01068Temperature properties of passive magnetic bearingBolotov Aleksander0Novikova Olga1Novikov Vladislav2Tver State Technical UniversityTver State Technical UniversityTver State Technical UniversityThe practical interest in passive magnetic bearings is due to the fact that they are not subject to wear and have insignificant dissipative energy losses. However, when the magnets are heated during operation, a reversible and irreversible decrease in the residual magnetization occurs and, consequently, the force of interaction between them changes. The thermal properties of passive magnetic bearings are adversely affected by the large demagnetizing fields from the coupled magnets. To predict the performance of passive magnetic bearings with regard to external temperature, an assessment of temperature changes in the bearing capacity of bearings with optimally shaped magnets is necessary. The optimum magnets were considered to be those with sizes, whose interaction force, reduced to a single volume of magnetic material, was the maximum. A magnetic system of two cylindrical magnets with equal radii and heights located coaxially or with some radial displacement was considered. The studies were carried out on cylindrical magnets made of SmCo5 alloy, capable of maintaining magnetically hard properties at temperatures up to 250°C. It was confirmed that irreversible changes in the magnetic force for bearings with optimally sized magnets are close to each other. The destabilizing (radial) magnetic force at small radial displacements of one of the magnets also irreversibly decreased. A temperature of 250°C defines the upper limit of the temperature range for the normal operation of magnetic bearings with SmCo5 magnets. It was found that as a result of the action of a demagnetizing field on magnets during heating, they develop a significant inhomogeneity of magnetization over the volume. After demagnetization of the magnets kept at a temperature of 260 °C, the force of their interaction reaches only 85 - 90% of the original, which is associated with microstructural changes in the magnets. Theoretically and experimentally, the numerical values of the temperature coefficients of changes in the bearing capacity and stiffness of bearings are determined.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/13/e3sconf_ersme2023_01068.pdf
spellingShingle Bolotov Aleksander
Novikova Olga
Novikov Vladislav
Temperature properties of passive magnetic bearing
E3S Web of Conferences
title Temperature properties of passive magnetic bearing
title_full Temperature properties of passive magnetic bearing
title_fullStr Temperature properties of passive magnetic bearing
title_full_unstemmed Temperature properties of passive magnetic bearing
title_short Temperature properties of passive magnetic bearing
title_sort temperature properties of passive magnetic bearing
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/13/e3sconf_ersme2023_01068.pdf
work_keys_str_mv AT bolotovaleksander temperaturepropertiesofpassivemagneticbearing
AT novikovaolga temperaturepropertiesofpassivemagneticbearing
AT novikovvladislav temperaturepropertiesofpassivemagneticbearing