Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector

The aime of this paper is to investigate the impact of annealing on track growth  rate (dL/dt), which is calculated using the track length measurement method. A 600 micro meter-thick CR-39 detector, divided into four samples (1 x 1 cm2), was  vertically irradiated by alpha particles with 2.6 MeV fro...

Full description

Bibliographic Details
Main Authors: Rasha wael, Mushtaq Al-Jubbori
Format: Article
Language:Arabic
Published: College of Education for Pure Sciences 2023-09-01
Series:مجلة التربية والعلم
Subjects:
Online Access:https://edusj.mosuljournals.com/article_178221_e05d6be2add0ae42a36e505e4d47fb56.pdf
_version_ 1797728946015436800
author Rasha wael
Mushtaq Al-Jubbori
author_facet Rasha wael
Mushtaq Al-Jubbori
author_sort Rasha wael
collection DOAJ
description The aime of this paper is to investigate the impact of annealing on track growth  rate (dL/dt), which is calculated using the track length measurement method. A 600 micro meter-thick CR-39 detector, divided into four samples (1 x 1 cm2), was  vertically irradiated by alpha particles with 2.6 MeV from a 241Am source which have max energy 5.48 MeV . The three samples were annealed at 100–140oC  by type 20o C  using oven Memmert U4079142. All samples were etched in a 6.25 N NaOH solution at 70±1 oC in a Memmert W200 water bath, the periodic etching time was 0.5 hours to 6  hours. The etched image was captured using a camera (MADC_5A) attached to a microscope (XSZ-H Series Biological Microscope). The bulk etch rate and diameters increase with increasing annealing temperatures. The new method used in this paper to calculate the experimental track length is based on the relation between track length and track diameter obtained from track-test software.
first_indexed 2024-03-12T11:21:40Z
format Article
id doaj.art-18a541f7bcc344078ecb655a33f8aaef
institution Directory Open Access Journal
issn 1812-125X
2664-2530
language Arabic
last_indexed 2024-03-12T11:21:40Z
publishDate 2023-09-01
publisher College of Education for Pure Sciences
record_format Article
series مجلة التربية والعلم
spelling doaj.art-18a541f7bcc344078ecb655a33f8aaef2023-09-01T18:04:20ZaraCollege of Education for Pure Sciencesمجلة التربية والعلم1812-125X2664-25302023-09-013231810.33899/edusj.2023.138444.1335178221Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track DetectorRasha wael0Mushtaq Al-Jubbori1Department of physics, College of Education for Pure Sciences, University of Mosul, Mosul, IraqDepartment of Physics, College of Education for Pure Science, Mosul University, Mosul-IraqThe aime of this paper is to investigate the impact of annealing on track growth  rate (dL/dt), which is calculated using the track length measurement method. A 600 micro meter-thick CR-39 detector, divided into four samples (1 x 1 cm2), was  vertically irradiated by alpha particles with 2.6 MeV from a 241Am source which have max energy 5.48 MeV . The three samples were annealed at 100–140oC  by type 20o C  using oven Memmert U4079142. All samples were etched in a 6.25 N NaOH solution at 70±1 oC in a Memmert W200 water bath, the periodic etching time was 0.5 hours to 6  hours. The etched image was captured using a camera (MADC_5A) attached to a microscope (XSZ-H Series Biological Microscope). The bulk etch rate and diameters increase with increasing annealing temperatures. The new method used in this paper to calculate the experimental track length is based on the relation between track length and track diameter obtained from track-test software.https://edusj.mosuljournals.com/article_178221_e05d6be2add0ae42a36e505e4d47fb56.pdfnuclear track detectors cr-39,,,،,؛heting annealing,,,،,؛chemical etching,,,،,؛track growth rate
spellingShingle Rasha wael
Mushtaq Al-Jubbori
Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector
مجلة التربية والعلم
nuclear track detectors cr-39,,
,،,؛heting annealing,,
,،,؛chemical etching,,
,،,؛track growth rate
title Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector
title_full Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector
title_fullStr Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector
title_full_unstemmed Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector
title_short Effect the Annealing on The Growth Length Rate of Alpha Particles Tracks in CR-39 Nuclear Track Detector
title_sort effect the annealing on the growth length rate of alpha particles tracks in cr 39 nuclear track detector
topic nuclear track detectors cr-39,,
,،,؛heting annealing,,
,،,؛chemical etching,,
,،,؛track growth rate
url https://edusj.mosuljournals.com/article_178221_e05d6be2add0ae42a36e505e4d47fb56.pdf
work_keys_str_mv AT rashawael effecttheannealingonthegrowthlengthrateofalphaparticlestracksincr39nucleartrackdetector
AT mushtaqaljubbori effecttheannealingonthegrowthlengthrateofalphaparticlestracksincr39nucleartrackdetector