Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.

PURPOSE:Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending ("best contrast"/BC) increases its accuracy in detecting edema an...

Full description

Bibliographic Details
Main Authors: Georg Bier, Malte N Bongers, Hendrik Ditt, Benjamin Bender, Ulrike Ernemann, Marius Horger
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2016-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4726582?pdf=render
_version_ 1811331073613758464
author Georg Bier
Malte N Bongers
Hendrik Ditt
Benjamin Bender
Ulrike Ernemann
Marius Horger
author_facet Georg Bier
Malte N Bongers
Hendrik Ditt
Benjamin Bender
Ulrike Ernemann
Marius Horger
author_sort Georg Bier
collection DOAJ
description PURPOSE:Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending ("best contrast"/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction). METHODS:We retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory-MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction. RESULTS:NECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%). CONCLUSIONS:This post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly.
first_indexed 2024-04-13T16:13:25Z
format Article
id doaj.art-18a6e163039b44d4a9aedb9f9813f18c
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-04-13T16:13:25Z
publishDate 2016-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-18a6e163039b44d4a9aedb9f9813f18c2022-12-22T02:40:08ZengPublic Library of Science (PLoS)PLoS ONE1932-62032016-01-01111e014737810.1371/journal.pone.0147378Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.Georg BierMalte N BongersHendrik DittBenjamin BenderUlrike ErnemannMarius HorgerPURPOSE:Ischemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending ("best contrast"/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction). METHODS:We retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory-MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction. RESULTS:NECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%). CONCLUSIONS:This post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly.http://europepmc.org/articles/PMC4726582?pdf=render
spellingShingle Georg Bier
Malte N Bongers
Hendrik Ditt
Benjamin Bender
Ulrike Ernemann
Marius Horger
Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.
PLoS ONE
title Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.
title_full Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.
title_fullStr Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.
title_full_unstemmed Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.
title_short Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.
title_sort accuracy of non enhanced ct in detecting early ischemic edema using frequency selective non linear blending
url http://europepmc.org/articles/PMC4726582?pdf=render
work_keys_str_mv AT georgbier accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT maltenbongers accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT hendrikditt accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT benjaminbender accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT ulrikeernemann accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending
AT mariushorger accuracyofnonenhancedctindetectingearlyischemicedemausingfrequencyselectivenonlinearblending