Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados

Medial mandibular flexure (MMF) is the functional approximation of hemi-mandibles in jaw opening and protrusion, which may affect conventional or implant-supported arch prostheses. OBJECTIVE: This study evaluated the intra- and inter-rater reliability of a digital image method for linear measurement...

Full description

Bibliographic Details
Main Authors: Rosemary Sadami Arai Shinkai, Simone de Andrade Canabarro, Caroline Bom Schmidt, Evandro Afonso Sartori
Format: Article
Language:English
Published: University of São Paulo 2004-12-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400020
_version_ 1811295513459294208
author Rosemary Sadami Arai Shinkai
Simone de Andrade Canabarro
Caroline Bom Schmidt
Evandro Afonso Sartori
author_facet Rosemary Sadami Arai Shinkai
Simone de Andrade Canabarro
Caroline Bom Schmidt
Evandro Afonso Sartori
author_sort Rosemary Sadami Arai Shinkai
collection DOAJ
description Medial mandibular flexure (MMF) is the functional approximation of hemi-mandibles in jaw opening and protrusion, which may affect conventional or implant-supported arch prostheses. OBJECTIVE: This study evaluated the intra- and inter-rater reliability of a digital image method for linear measurement of MMF in dentate subjects. MATERIAL AND METHODS: Mandibular occlusal impressions in vinyl polysiloxane during rest and maximum opening were obtained from seven adult volunteers. Each impression and the Mitutoyo digital calipers with a 10mm opening were scanned at a 200% magnification. The images were processed using Adobe Photoshop software to get reference points on contralateral first molars. Linear intermolar measurements were taken using the Image Tool software (UTHSCSA), which was calibrated with the standard opening of the digital calipers. Intermolar distance was measured in triplicate for each image by two independent examiners. MMF was calculated by subtracting the intermolar distance in maximum opening (or protrusion) from the distance in rest position. Data were analyzed by intraclass correlation (ICC) tests for estimating intra- and inter-rater reliability. RESULTS: MMF values ranged from -0.21 to 0.44mm. Intra-rater ICCs were 0.982 and 0.993, and inter-rater ICC was 0.696. CONCLUSION: The present results show excellent intra-rater and good inter-rater reliability of this digital image method for measuring MMF in dentate subjects.<br>A deflexão mandibular medial (MMF) é uma deformação funcional que ocorre com a aproximação das hemi-mandíbulas em abertura e protrusão, podendo afetar próteses convencionais e implanto-suportadas em arco. OBJETIVOS: Este trabalho avaliou a confiabilidade intra- e inter-examinador de um método de imagem digital para aferição linear da MMF. MATERIAL E MÉTODOS: Foram selecionados sete voluntários adultos dentados, obtendo-se registros oclusais inferiores de silicona de adição em repouso, abertura e protrusão máximas. Os registros foram escaneados juntamente com um paquímetro Mitutoyo com abertura de 10mm num aumento de 200%. A imagem foi processada no programa Adobe Photoshop obtendo-se pontos de referência intermolares, e as medições lineares foram feitas no programa ImageTool (UTHSCSA) calibrado com a medida padrão do paquímetro. Foram feitas medições em triplicata da medida da distância intermolar para cada imagem. A MMF foi calculada subtraindo-se a distância intermolar em abertura da distância em repouso/ protrusão. Os dados foram analisados por coeficientes de correlação intraclasse (ICC) para estimar a confiabilidade intra- e inter-examinadores. RESULTADOS: Os valores de MMF variaram de -0,21 a 0,44mm. Os ICCs intra-examinador foram 0,982 e 0,993, e o ICC inter-examinador foi 0,696. CONCLUSÃO: Os resultados demonstram excelente confiabilidade intra-examinador e boa confiabilidade inter-examinador deste método de imagem digital para aferição de MMF em adultos dentados.
first_indexed 2024-04-13T05:33:37Z
format Article
id doaj.art-18bac23e46d3477e86125498af3f6ade
institution Directory Open Access Journal
issn 1678-7757
1678-7765
language English
last_indexed 2024-04-13T05:33:37Z
publishDate 2004-12-01
publisher University of São Paulo
record_format Article
series Journal of Applied Oral Science
spelling doaj.art-18bac23e46d3477e86125498af3f6ade2022-12-22T03:00:21ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652004-12-0112435836210.1590/S1678-77572004000400020Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentadosRosemary Sadami Arai ShinkaiSimone de Andrade CanabarroCaroline Bom SchmidtEvandro Afonso SartoriMedial mandibular flexure (MMF) is the functional approximation of hemi-mandibles in jaw opening and protrusion, which may affect conventional or implant-supported arch prostheses. OBJECTIVE: This study evaluated the intra- and inter-rater reliability of a digital image method for linear measurement of MMF in dentate subjects. MATERIAL AND METHODS: Mandibular occlusal impressions in vinyl polysiloxane during rest and maximum opening were obtained from seven adult volunteers. Each impression and the Mitutoyo digital calipers with a 10mm opening were scanned at a 200% magnification. The images were processed using Adobe Photoshop software to get reference points on contralateral first molars. Linear intermolar measurements were taken using the Image Tool software (UTHSCSA), which was calibrated with the standard opening of the digital calipers. Intermolar distance was measured in triplicate for each image by two independent examiners. MMF was calculated by subtracting the intermolar distance in maximum opening (or protrusion) from the distance in rest position. Data were analyzed by intraclass correlation (ICC) tests for estimating intra- and inter-rater reliability. RESULTS: MMF values ranged from -0.21 to 0.44mm. Intra-rater ICCs were 0.982 and 0.993, and inter-rater ICC was 0.696. CONCLUSION: The present results show excellent intra-rater and good inter-rater reliability of this digital image method for measuring MMF in dentate subjects.<br>A deflexão mandibular medial (MMF) é uma deformação funcional que ocorre com a aproximação das hemi-mandíbulas em abertura e protrusão, podendo afetar próteses convencionais e implanto-suportadas em arco. OBJETIVOS: Este trabalho avaliou a confiabilidade intra- e inter-examinador de um método de imagem digital para aferição linear da MMF. MATERIAL E MÉTODOS: Foram selecionados sete voluntários adultos dentados, obtendo-se registros oclusais inferiores de silicona de adição em repouso, abertura e protrusão máximas. Os registros foram escaneados juntamente com um paquímetro Mitutoyo com abertura de 10mm num aumento de 200%. A imagem foi processada no programa Adobe Photoshop obtendo-se pontos de referência intermolares, e as medições lineares foram feitas no programa ImageTool (UTHSCSA) calibrado com a medida padrão do paquímetro. Foram feitas medições em triplicata da medida da distância intermolar para cada imagem. A MMF foi calculada subtraindo-se a distância intermolar em abertura da distância em repouso/ protrusão. Os dados foram analisados por coeficientes de correlação intraclasse (ICC) para estimar a confiabilidade intra- e inter-examinadores. RESULTADOS: Os valores de MMF variaram de -0,21 a 0,44mm. Os ICCs intra-examinador foram 0,982 e 0,993, e o ICC inter-examinador foi 0,696. CONCLUSÃO: Os resultados demonstram excelente confiabilidade intra-examinador e boa confiabilidade inter-examinador deste método de imagem digital para aferição de MMF em adultos dentados.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400020Arco dentárioMandíbulaDeflexão mandibularDental archJawMandibleMandibular flexure
spellingShingle Rosemary Sadami Arai Shinkai
Simone de Andrade Canabarro
Caroline Bom Schmidt
Evandro Afonso Sartori
Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados
Journal of Applied Oral Science
Arco dentário
Mandíbula
Deflexão mandibular
Dental arch
Jaw
Mandible
Mandibular flexure
title Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados
title_full Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados
title_fullStr Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados
title_full_unstemmed Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados
title_short Reliability of a digital image method for measuring medial mandibular flexure in dentate subjects Confiabilidade de um método de imagem digital para medição de deflexão mandibular medial em adultos dentados
title_sort reliability of a digital image method for measuring medial mandibular flexure in dentate subjects confiabilidade de um metodo de imagem digital para medicao de deflexao mandibular medial em adultos dentados
topic Arco dentário
Mandíbula
Deflexão mandibular
Dental arch
Jaw
Mandible
Mandibular flexure
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572004000400020
work_keys_str_mv AT rosemarysadamiaraishinkai reliabilityofadigitalimagemethodformeasuringmedialmandibularflexureindentatesubjectsconfiabilidadedeummetododeimagemdigitalparamedicaodedeflexaomandibularmedialemadultosdentados
AT simonedeandradecanabarro reliabilityofadigitalimagemethodformeasuringmedialmandibularflexureindentatesubjectsconfiabilidadedeummetododeimagemdigitalparamedicaodedeflexaomandibularmedialemadultosdentados
AT carolinebomschmidt reliabilityofadigitalimagemethodformeasuringmedialmandibularflexureindentatesubjectsconfiabilidadedeummetododeimagemdigitalparamedicaodedeflexaomandibularmedialemadultosdentados
AT evandroafonsosartori reliabilityofadigitalimagemethodformeasuringmedialmandibularflexureindentatesubjectsconfiabilidadedeummetododeimagemdigitalparamedicaodedeflexaomandibularmedialemadultosdentados