Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation

Geant4 simulation was applied to correct the coincidence summing (CS) effect in detecting a volumetric γ-ray sources, and this technique was applied to a152Eu standard sources. The radioactive sources were a liquid cylindrical, rectangular, and Marinelli beaker shapes of different volume for each on...

Full description

Bibliographic Details
Main Authors: Dalal Abdullah Aloraini, Mohamed Elsafi, Aljawhara H. Almuqrin, M.I. Sayyed
Format: Article
Language:English
Published: Hindawi Limited 2022-01-01
Series:Science and Technology of Nuclear Installations
Online Access:http://dx.doi.org/10.1155/2022/5718920
_version_ 1798033081617088512
author Dalal Abdullah Aloraini
Mohamed Elsafi
Aljawhara H. Almuqrin
M.I. Sayyed
author_facet Dalal Abdullah Aloraini
Mohamed Elsafi
Aljawhara H. Almuqrin
M.I. Sayyed
author_sort Dalal Abdullah Aloraini
collection DOAJ
description Geant4 simulation was applied to correct the coincidence summing (CS) effect in detecting a volumetric γ-ray sources, and this technique was applied to a152Eu standard sources. The radioactive sources were a liquid cylindrical, rectangular, and Marinelli beaker shapes of different volume for each one. Radionuclide track (RT) including coincidence summing and monoenergetic track without coincidence summing. The results obtained from two approaches compared with the experimental data and the modified KORSUM code for cylindrical γ-ray source. The comparison showed that the adopted method in this investigation is useful for coincidence summing corrections for a voluminous γ-ray sources.Moreover, this technique requires far less computation time than the techniques that depend on the calculation of total efficiency.
first_indexed 2024-04-11T20:24:34Z
format Article
id doaj.art-1941ae315a784b96b5fddefa75067425
institution Directory Open Access Journal
issn 1687-6083
language English
last_indexed 2024-04-11T20:24:34Z
publishDate 2022-01-01
publisher Hindawi Limited
record_format Article
series Science and Technology of Nuclear Installations
spelling doaj.art-1941ae315a784b96b5fddefa750674252022-12-22T04:04:42ZengHindawi LimitedScience and Technology of Nuclear Installations1687-60832022-01-01202210.1155/2022/5718920Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 SimulationDalal Abdullah Aloraini0Mohamed Elsafi1Aljawhara H. Almuqrin2M.I. Sayyed3Department of PhysicsPhysics DepartmentDepartment of PhysicsDepartment of PhysicsGeant4 simulation was applied to correct the coincidence summing (CS) effect in detecting a volumetric γ-ray sources, and this technique was applied to a152Eu standard sources. The radioactive sources were a liquid cylindrical, rectangular, and Marinelli beaker shapes of different volume for each one. Radionuclide track (RT) including coincidence summing and monoenergetic track without coincidence summing. The results obtained from two approaches compared with the experimental data and the modified KORSUM code for cylindrical γ-ray source. The comparison showed that the adopted method in this investigation is useful for coincidence summing corrections for a voluminous γ-ray sources.Moreover, this technique requires far less computation time than the techniques that depend on the calculation of total efficiency.http://dx.doi.org/10.1155/2022/5718920
spellingShingle Dalal Abdullah Aloraini
Mohamed Elsafi
Aljawhara H. Almuqrin
M.I. Sayyed
Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
Science and Technology of Nuclear Installations
title Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
title_full Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
title_fullStr Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
title_full_unstemmed Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
title_short Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation
title_sort coincidence summing factor calculation for volumetric γ ray sources using geant4 simulation
url http://dx.doi.org/10.1155/2022/5718920
work_keys_str_mv AT dalalabdullahaloraini coincidencesummingfactorcalculationforvolumetricgraysourcesusinggeant4simulation
AT mohamedelsafi coincidencesummingfactorcalculationforvolumetricgraysourcesusinggeant4simulation
AT aljawharahalmuqrin coincidencesummingfactorcalculationforvolumetricgraysourcesusinggeant4simulation
AT misayyed coincidencesummingfactorcalculationforvolumetricgraysourcesusinggeant4simulation