On Adjusting the Load Bearing Capacity of Decisive Members to Reliability Classes of Statically Determinate Complex Structures

The paper provides a solution to the problem of dimensioning decisive bars on the basis of the conditions of meeting the recommended reliability classes [9] of statically determinate structures composed of n members. A theorem was formulated: if a statically determinate structure composed of n decis...

Full description

Bibliographic Details
Main Author: Kowal Z.
Format: Article
Language:English
Published: Polish Academy of Sciences 2013-03-01
Series:Archives of Civil Engineering
Subjects:
Online Access:http://www.degruyter.com/view/j/ace.2013.59.issue-1/ace-2013-0006/ace-2013-0006.xml?format=INT
Description
Summary:The paper provides a solution to the problem of dimensioning decisive bars on the basis of the conditions of meeting the recommended reliability classes [9] of statically determinate structures composed of n members. A theorem was formulated: if a statically determinate structure composed of n decisive members is to attain the reliability greater than, or equal to, the recommended reliability p = 1- q, it is necessary and sufficient that the damage frequency sum qi of decisive members is smaller than the admissible damage frequency q of the structure: Σqi < q. On the basis of this theorem, s coefficients that recommend increase of the load bearing capacity of the decisive bars in a statically determinate structure constructed in order to meet the recommended class [9] of the structure reliability, are estimated and presented in a tabular form.
ISSN:1230-2945