Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
Abstract Objective To review current literature and experience with Gore‐TexⓇ implant extrusion following medialization thyroplasty, as well as to report the unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Methods Review of existing literature and description...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-09-01
|
Series: | World Journal of Otorhinolaryngology-Head and Neck Surgery |
Subjects: | |
Online Access: | https://doi.org/10.1016/j.wjorl.2020.08.001 |
_version_ | 1811185585232019456 |
---|---|
author | Ariel Frost Natasha Mirza |
author_facet | Ariel Frost Natasha Mirza |
author_sort | Ariel Frost |
collection | DOAJ |
description | Abstract Objective To review current literature and experience with Gore‐TexⓇ implant extrusion following medialization thyroplasty, as well as to report the unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Methods Review of existing literature and description of personal experience with unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Results Review of existing literature found no prior reported cases of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Risk factors for implant extrusion include the pressure of the implant on insertion and the inability to secure the implant. Cases of implant extrusion can be managed operatively via an endoscopic or via an external open approach. Conclusion This is the first reported case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Careful consideration should be given in revision medialization thyroplasty as additional implant material may cause increased pressure, a risk factor for implant extrusion. |
first_indexed | 2024-04-11T13:32:55Z |
format | Article |
id | doaj.art-197054818f384344b2f2d0a4a29488d7 |
institution | Directory Open Access Journal |
issn | 2095-8811 2589-1081 |
language | English |
last_indexed | 2024-04-11T13:32:55Z |
publishDate | 2022-09-01 |
publisher | Wiley |
record_format | Article |
series | World Journal of Otorhinolaryngology-Head and Neck Surgery |
spelling | doaj.art-197054818f384344b2f2d0a4a29488d72022-12-22T04:21:44ZengWileyWorld Journal of Otorhinolaryngology-Head and Neck Surgery2095-88112589-10812022-09-018321321610.1016/j.wjorl.2020.08.001Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literatureAriel Frost0Natasha Mirza1Department of Otorhinolaryngology ‐ Head & Neck Surgery University of Pennsylvania Philadelphia PA USADepartment of Otorhinolaryngology ‐ Head & Neck Surgery University of Pennsylvania Philadelphia PA USAAbstract Objective To review current literature and experience with Gore‐TexⓇ implant extrusion following medialization thyroplasty, as well as to report the unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Methods Review of existing literature and description of personal experience with unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Results Review of existing literature found no prior reported cases of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Risk factors for implant extrusion include the pressure of the implant on insertion and the inability to secure the implant. Cases of implant extrusion can be managed operatively via an endoscopic or via an external open approach. Conclusion This is the first reported case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Careful consideration should be given in revision medialization thyroplasty as additional implant material may cause increased pressure, a risk factor for implant extrusion.https://doi.org/10.1016/j.wjorl.2020.08.001ComplicationsGore‐TexⓇImplant extrusionLaryngoplastyMedialization thyroplastyRevision |
spellingShingle | Ariel Frost Natasha Mirza Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature World Journal of Otorhinolaryngology-Head and Neck Surgery Complications Gore‐TexⓇ Implant extrusion Laryngoplasty Medialization thyroplasty Revision |
title | Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature |
title_full | Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature |
title_fullStr | Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature |
title_full_unstemmed | Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature |
title_short | Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature |
title_sort | gore tex implant extrusion following revision medialization thyroplasty case report and review of the literature |
topic | Complications Gore‐TexⓇ Implant extrusion Laryngoplasty Medialization thyroplasty Revision |
url | https://doi.org/10.1016/j.wjorl.2020.08.001 |
work_keys_str_mv | AT arielfrost goreteximplantextrusionfollowingrevisionmedializationthyroplastycasereportandreviewoftheliterature AT natashamirza goreteximplantextrusionfollowingrevisionmedializationthyroplastycasereportandreviewoftheliterature |