Optimization strategy of switching modulation of mine—used high—voltage frequency converter

For problems of high switching loss and power quality distortion when carrier modulation PWM control method were used in mine—used high—voltage frequency converter. Sinusoidal modulation wave was optimized based on carrier—in—phase disposition PWM control method. The sinusoidal modulation wave is su...

Full description

Bibliographic Details
Main Authors: LI Zhaoping, ZHANG Hongjuan, JIN Baoquan, GAO Yan, HUANG Fei, WANG Yuxing
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2018-11-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671—251x.2018050033
Description
Summary:For problems of high switching loss and power quality distortion when carrier modulation PWM control method were used in mine—used high—voltage frequency converter. Sinusoidal modulation wave was optimized based on carrier—in—phase disposition PWM control method. The sinusoidal modulation wave is superimposing with the third harmonic and direct current component, so as to obtain an optimized modulation wave with saddle—shaped modulation wave in positive half—cycle and trapezoidal modulation wave in negative half—cycle. The simulation results show that DC voltage utilization of frequency converter is improved, switching loss and total harmonic distortion of output line voltage is reduced by use of the optimized modulation wave.