Eye Biometry Shift after Scleral Buckling Procedure

Background. There are a great number publications presenting results of various types of optical and ultrasound biometry before and after scleral buckling (SB).Patients and methods. Biometry was performed for 22 eyes of 22 patients before and after surgical treatment of rhegmatogenous retinal detach...

Full description

Bibliographic Details
Main Authors: A. N. Kulikov, E. V. Danilenko, A. R. Kuznetsov
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2022-10-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/1912
_version_ 1827063027424296960
author A. N. Kulikov
E. V. Danilenko
A. R. Kuznetsov
author_facet A. N. Kulikov
E. V. Danilenko
A. R. Kuznetsov
author_sort A. N. Kulikov
collection DOAJ
description Background. There are a great number publications presenting results of various types of optical and ultrasound biometry before and after scleral buckling (SB).Patients and methods. Biometry was performed for 22 eyes of 22 patients before and after surgical treatment of rhegmatogenous retinal detachment. We used 4 types of optical (IOLMaster 500, IOLMaster 700, Lenstar LS 900 and REVO SOCT Copernicus) and 2 types of ultrasound biometry (A- and B-scan).Results. According to the all biometry data, there was an increase in the axial lens (AL) (the maximum value of eye elongation according to IOLMaster 500 data was 0.84 ± 0.69 mm, p = 0.000), swallowing of the anterior chamber depth (ACD) in regard to IOLMaster 700 (0,48 ± 0,32 mm, p = 0.000) and lens thickness (LT) augmentation (according to A-scan data the largest thickening was 0.17 ± 0.59 mm, p = 0.064).Conclusions. The anatomy of the eye reliably changes after SB implantation due to increase in the AL, ACD swallowing and an LT augmentation, that makes changes in IOL power calculation with modern formulas during combined surgery. Lenstar LS 900 is the preferred method of biometry when planning simultaneously lens exchange with SB procedure.
first_indexed 2024-04-10T01:46:21Z
format Article
id doaj.art-19a2cb66aa3d4cd5bd5d18f346141a76
institution Directory Open Access Journal
issn 1816-5095
2500-0845
language Russian
last_indexed 2025-02-18T20:07:46Z
publishDate 2022-10-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj.art-19a2cb66aa3d4cd5bd5d18f346141a762024-10-17T16:12:01ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452022-10-0119349349910.18008/1816-5095-2022-3-493-499933Eye Biometry Shift after Scleral Buckling ProcedureA. N. Kulikov0E. V. Danilenko1A. R. Kuznetsov2Military medical academy named after S.M. KirovMilitary medical academy named after S.M. KirovMilitary medical academy named after S.M. KirovBackground. There are a great number publications presenting results of various types of optical and ultrasound biometry before and after scleral buckling (SB).Patients and methods. Biometry was performed for 22 eyes of 22 patients before and after surgical treatment of rhegmatogenous retinal detachment. We used 4 types of optical (IOLMaster 500, IOLMaster 700, Lenstar LS 900 and REVO SOCT Copernicus) and 2 types of ultrasound biometry (A- and B-scan).Results. According to the all biometry data, there was an increase in the axial lens (AL) (the maximum value of eye elongation according to IOLMaster 500 data was 0.84 ± 0.69 mm, p = 0.000), swallowing of the anterior chamber depth (ACD) in regard to IOLMaster 700 (0,48 ± 0,32 mm, p = 0.000) and lens thickness (LT) augmentation (according to A-scan data the largest thickening was 0.17 ± 0.59 mm, p = 0.064).Conclusions. The anatomy of the eye reliably changes after SB implantation due to increase in the AL, ACD swallowing and an LT augmentation, that makes changes in IOL power calculation with modern formulas during combined surgery. Lenstar LS 900 is the preferred method of biometry when planning simultaneously lens exchange with SB procedure.https://www.ophthalmojournal.com/opht/article/view/1912scleral buckling procedureoptical biometryultrasound biometryintraocular lens
spellingShingle A. N. Kulikov
E. V. Danilenko
A. R. Kuznetsov
Eye Biometry Shift after Scleral Buckling Procedure
Oftalʹmologiâ
scleral buckling procedure
optical biometry
ultrasound biometry
intraocular lens
title Eye Biometry Shift after Scleral Buckling Procedure
title_full Eye Biometry Shift after Scleral Buckling Procedure
title_fullStr Eye Biometry Shift after Scleral Buckling Procedure
title_full_unstemmed Eye Biometry Shift after Scleral Buckling Procedure
title_short Eye Biometry Shift after Scleral Buckling Procedure
title_sort eye biometry shift after scleral buckling procedure
topic scleral buckling procedure
optical biometry
ultrasound biometry
intraocular lens
url https://www.ophthalmojournal.com/opht/article/view/1912
work_keys_str_mv AT ankulikov eyebiometryshiftafterscleralbucklingprocedure
AT evdanilenko eyebiometryshiftafterscleralbucklingprocedure
AT arkuznetsov eyebiometryshiftafterscleralbucklingprocedure