Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector

An active collimator has been designed to replace the heavy metal collimator of the BGO anti-Compton shield to improve the performance of the hybrid Indian National Gamma Array (INGA) at TIFR, Mumbai. The active collimators of the 24 clover detectors, along with the BGO anti-Compton shields and 18 L...

Full description

Bibliographic Details
Main Authors: Das Biswajit, Khan Chowdhury N.R., Saha S., Laskar Md.R.S., Babra F.S., Malik V., Kundu A., Dey P., Jadav S.K., Naidu B.S., Vazhappilly A.T., Sihotra S., Palit R.
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:EPJ Web of Conferences
Subjects:
Online Access:https://www.epj-conferences.org/articles/epjconf/pdf/2023/14/epjconf_animma2023_10004.pdf
_version_ 1797343997338845184
author Das Biswajit
Khan Chowdhury N.R.
Saha S.
Laskar Md.R.S.
Babra F.S.
Malik V.
Kundu A.
Dey P.
Jadav S.K.
Naidu B.S.
Vazhappilly A.T.
Sihotra S.
Palit R.
author_facet Das Biswajit
Khan Chowdhury N.R.
Saha S.
Laskar Md.R.S.
Babra F.S.
Malik V.
Kundu A.
Dey P.
Jadav S.K.
Naidu B.S.
Vazhappilly A.T.
Sihotra S.
Palit R.
author_sort Das Biswajit
collection DOAJ
description An active collimator has been designed to replace the heavy metal collimator of the BGO anti-Compton shield to improve the performance of the hybrid Indian National Gamma Array (INGA) at TIFR, Mumbai. The active collimators of the 24 clover detectors, along with the BGO anti-Compton shields and 18 LaBr3(Ce) detectors, can act as a γ-ray multiplicity filter. This configuration will be beneficial for studying weak band structures decaying by high γ-ray multiplicity events. In addition, the energy deposited in all the detectors can be added to get the sum energy for certain measurements aiming to use the hybrid array for calorimetric application. We have characterized an active collimator coupled with one of the anti-Compton shields and an HPGe clover detector with various radioactive sources. The peak-to-total ratio for the active collimator configuration is similar to the standard design with the heavy metal configuration with the 60Co source. Additionally, we have evaluated the Compton cross-talk between the clover HPGe detector and the anti-Compton shield/active collimator. The total multiplicity distribution for a cascade of eleven γ-rays with an energy range of 702000 keV has been obtained through GEANT4 simulation. The simulation results indicate the possibility of conducting a meaningful study of decay chains with a multiplicity of twelve.
first_indexed 2024-03-08T10:55:55Z
format Article
id doaj.art-19d799dca7f54cef8d2f22dea8b37f47
institution Directory Open Access Journal
issn 2100-014X
language English
last_indexed 2024-03-08T10:55:55Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series EPJ Web of Conferences
spelling doaj.art-19d799dca7f54cef8d2f22dea8b37f472024-01-26T16:33:48ZengEDP SciencesEPJ Web of Conferences2100-014X2023-01-012881000410.1051/epjconf/202328810004epjconf_animma2023_10004Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover DetectorDas Biswajit0Khan Chowdhury N.R.1Saha S.2Laskar Md.R.S.3Babra F.S.4Malik V.5Kundu A.6Dey P.7Jadav S.K.8Naidu B.S.9Vazhappilly A.T.10Sihotra S.11Palit R.12Department of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchSchool of Advanced Sciences, VIT UniversityDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Physics, Panjab UniversityDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchAn active collimator has been designed to replace the heavy metal collimator of the BGO anti-Compton shield to improve the performance of the hybrid Indian National Gamma Array (INGA) at TIFR, Mumbai. The active collimators of the 24 clover detectors, along with the BGO anti-Compton shields and 18 LaBr3(Ce) detectors, can act as a γ-ray multiplicity filter. This configuration will be beneficial for studying weak band structures decaying by high γ-ray multiplicity events. In addition, the energy deposited in all the detectors can be added to get the sum energy for certain measurements aiming to use the hybrid array for calorimetric application. We have characterized an active collimator coupled with one of the anti-Compton shields and an HPGe clover detector with various radioactive sources. The peak-to-total ratio for the active collimator configuration is similar to the standard design with the heavy metal configuration with the 60Co source. Additionally, we have evaluated the Compton cross-talk between the clover HPGe detector and the anti-Compton shield/active collimator. The total multiplicity distribution for a cascade of eleven γ-rays with an energy range of 702000 keV has been obtained through GEANT4 simulation. The simulation results indicate the possibility of conducting a meaningful study of decay chains with a multiplicity of twelve.https://www.epj-conferences.org/articles/epjconf/pdf/2023/14/epjconf_animma2023_10004.pdfγ-ray detector developmentdesign and characterization of an active collimator; benefits for higher multiplicity decay study in inga; geant4 simulation
spellingShingle Das Biswajit
Khan Chowdhury N.R.
Saha S.
Laskar Md.R.S.
Babra F.S.
Malik V.
Kundu A.
Dey P.
Jadav S.K.
Naidu B.S.
Vazhappilly A.T.
Sihotra S.
Palit R.
Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
EPJ Web of Conferences
γ-ray detector development
design and characterization of an active collimator; benefits for higher multiplicity decay study in inga; geant4 simulation
title Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
title_full Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
title_fullStr Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
title_full_unstemmed Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
title_short Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
title_sort active collimator for the bgo anti compton shield of the hpge clover detector
topic γ-ray detector development
design and characterization of an active collimator; benefits for higher multiplicity decay study in inga; geant4 simulation
url https://www.epj-conferences.org/articles/epjconf/pdf/2023/14/epjconf_animma2023_10004.pdf
work_keys_str_mv AT dasbiswajit activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT khanchowdhurynr activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT sahas activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT laskarmdrs activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT babrafs activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT malikv activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT kundua activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT deyp activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT jadavsk activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT naidubs activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT vazhappillyat activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT sihotras activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector
AT palitr activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector