Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector
An active collimator has been designed to replace the heavy metal collimator of the BGO anti-Compton shield to improve the performance of the hybrid Indian National Gamma Array (INGA) at TIFR, Mumbai. The active collimators of the 24 clover detectors, along with the BGO anti-Compton shields and 18 L...
Main Authors: | , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2023-01-01
|
Series: | EPJ Web of Conferences |
Subjects: | |
Online Access: | https://www.epj-conferences.org/articles/epjconf/pdf/2023/14/epjconf_animma2023_10004.pdf |
_version_ | 1797343997338845184 |
---|---|
author | Das Biswajit Khan Chowdhury N.R. Saha S. Laskar Md.R.S. Babra F.S. Malik V. Kundu A. Dey P. Jadav S.K. Naidu B.S. Vazhappilly A.T. Sihotra S. Palit R. |
author_facet | Das Biswajit Khan Chowdhury N.R. Saha S. Laskar Md.R.S. Babra F.S. Malik V. Kundu A. Dey P. Jadav S.K. Naidu B.S. Vazhappilly A.T. Sihotra S. Palit R. |
author_sort | Das Biswajit |
collection | DOAJ |
description | An active collimator has been designed to replace the heavy metal collimator of the BGO anti-Compton shield to improve the performance of the hybrid Indian National Gamma Array (INGA) at TIFR, Mumbai. The active collimators of the 24 clover detectors, along with the BGO anti-Compton shields and 18 LaBr3(Ce) detectors, can act as a γ-ray multiplicity filter. This configuration will be beneficial for studying weak band structures decaying by high γ-ray multiplicity events. In addition, the energy deposited in all the detectors can be added to get the sum energy for certain measurements aiming to use the hybrid array for calorimetric application. We have characterized an active collimator coupled with one of the anti-Compton shields and an HPGe clover detector with various radioactive sources. The peak-to-total ratio for the active collimator configuration is similar to the standard design with the heavy metal configuration with the 60Co source. Additionally, we have evaluated the Compton cross-talk between the clover HPGe detector and the anti-Compton shield/active collimator. The total multiplicity distribution for a cascade of eleven γ-rays with an energy range of 702000 keV has been obtained through GEANT4 simulation. The simulation results indicate the possibility of conducting a meaningful study of decay chains with a multiplicity of twelve. |
first_indexed | 2024-03-08T10:55:55Z |
format | Article |
id | doaj.art-19d799dca7f54cef8d2f22dea8b37f47 |
institution | Directory Open Access Journal |
issn | 2100-014X |
language | English |
last_indexed | 2024-03-08T10:55:55Z |
publishDate | 2023-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | EPJ Web of Conferences |
spelling | doaj.art-19d799dca7f54cef8d2f22dea8b37f472024-01-26T16:33:48ZengEDP SciencesEPJ Web of Conferences2100-014X2023-01-012881000410.1051/epjconf/202328810004epjconf_animma2023_10004Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover DetectorDas Biswajit0Khan Chowdhury N.R.1Saha S.2Laskar Md.R.S.3Babra F.S.4Malik V.5Kundu A.6Dey P.7Jadav S.K.8Naidu B.S.9Vazhappilly A.T.10Sihotra S.11Palit R.12Department of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchSchool of Advanced Sciences, VIT UniversityDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchDepartment of Physics, Panjab UniversityDepartment of Nuclear and Atomic Physics Tata Institute of Fundamental ResearchAn active collimator has been designed to replace the heavy metal collimator of the BGO anti-Compton shield to improve the performance of the hybrid Indian National Gamma Array (INGA) at TIFR, Mumbai. The active collimators of the 24 clover detectors, along with the BGO anti-Compton shields and 18 LaBr3(Ce) detectors, can act as a γ-ray multiplicity filter. This configuration will be beneficial for studying weak band structures decaying by high γ-ray multiplicity events. In addition, the energy deposited in all the detectors can be added to get the sum energy for certain measurements aiming to use the hybrid array for calorimetric application. We have characterized an active collimator coupled with one of the anti-Compton shields and an HPGe clover detector with various radioactive sources. The peak-to-total ratio for the active collimator configuration is similar to the standard design with the heavy metal configuration with the 60Co source. Additionally, we have evaluated the Compton cross-talk between the clover HPGe detector and the anti-Compton shield/active collimator. The total multiplicity distribution for a cascade of eleven γ-rays with an energy range of 702000 keV has been obtained through GEANT4 simulation. The simulation results indicate the possibility of conducting a meaningful study of decay chains with a multiplicity of twelve.https://www.epj-conferences.org/articles/epjconf/pdf/2023/14/epjconf_animma2023_10004.pdfγ-ray detector developmentdesign and characterization of an active collimator; benefits for higher multiplicity decay study in inga; geant4 simulation |
spellingShingle | Das Biswajit Khan Chowdhury N.R. Saha S. Laskar Md.R.S. Babra F.S. Malik V. Kundu A. Dey P. Jadav S.K. Naidu B.S. Vazhappilly A.T. Sihotra S. Palit R. Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector EPJ Web of Conferences γ-ray detector development design and characterization of an active collimator; benefits for higher multiplicity decay study in inga; geant4 simulation |
title | Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector |
title_full | Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector |
title_fullStr | Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector |
title_full_unstemmed | Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector |
title_short | Active Collimator for the BGO Anti-Compton Shield of the HPGe Clover Detector |
title_sort | active collimator for the bgo anti compton shield of the hpge clover detector |
topic | γ-ray detector development design and characterization of an active collimator; benefits for higher multiplicity decay study in inga; geant4 simulation |
url | https://www.epj-conferences.org/articles/epjconf/pdf/2023/14/epjconf_animma2023_10004.pdf |
work_keys_str_mv | AT dasbiswajit activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT khanchowdhurynr activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT sahas activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT laskarmdrs activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT babrafs activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT malikv activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT kundua activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT deyp activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT jadavsk activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT naidubs activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT vazhappillyat activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT sihotras activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector AT palitr activecollimatorforthebgoanticomptonshieldofthehpgecloverdetector |