A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects

Abstract CO2-EOR is one of the principal techniques for enhanced oil recovery (EOR). The CO2 injection not only promotes oil recovery but also leads to greenhouse gas discharge reduction. Nonetheless, a key challenge in the CO2 flooding process is a premature CO2 breakthrough from highly permeable z...

Full description

Bibliographic Details
Main Authors: Hamed Rezvani, Yousef Rafiei
Format: Article
Language:English
Published: SpringerOpen 2023-06-01
Series:Journal of Petroleum Exploration and Production Technology
Subjects:
Online Access:https://doi.org/10.1007/s13202-023-01654-x
_version_ 1797774332450045952
author Hamed Rezvani
Yousef Rafiei
author_facet Hamed Rezvani
Yousef Rafiei
author_sort Hamed Rezvani
collection DOAJ
description Abstract CO2-EOR is one of the principal techniques for enhanced oil recovery (EOR). The CO2 injection not only promotes oil recovery but also leads to greenhouse gas discharge reduction. Nonetheless, a key challenge in the CO2 flooding process is a premature CO2 breakthrough from highly permeable zones. In recent years, Inflow Control Devices, ICDs, have been used as a potential solution to mitigate an early gas breakthrough. The key and important parameter in ICDs installation is obtaining its opening flow area. The common ways to obtain the ICD flow area such as utilizing optimization algorithms are very complicated and time-consuming, and further these methods are not analytical. The aim of this work is to solve the mentioned challenges—postpone the breakthrough time in gas injection and present an easy, fast, and analytical technique for obtaining ICDs flow area. This paper presents a new analytical method for obtaining inflow control devices flow area for injection wells in an oil reservoir under CO2-EOR in order to balance the injected CO2 front movement in all layers. Then, in order to compare the advantages and disadvantages of the presented technique with other methods such as optimization algorithms, a case study has been done on a real reservoir model under CO2 injection. Later, the results of studied scenarios in the case studied are given and compared. The results show that by utilizing the proposed method recovery factor is raised by improving sweep efficiency, and the breakthrough time is more postponed compared to the other methods about 400 days. Further, the ICD flow area calculation takes 2 min by presented analytical techniques, but the optimization algorithm takes 4040 min to run the simulation model to find the ICD flow area. In the end, the findings of the presented analytical formula can help to set the ICD flow area very fast without the simulation and help researchers for a better quantitative understanding of parameters affecting the ICD flow area by the given formula such as reservoir permeability.
first_indexed 2024-03-12T22:19:29Z
format Article
id doaj.art-19f209e21a304bf3820d90519a77002c
institution Directory Open Access Journal
issn 2190-0558
2190-0566
language English
last_indexed 2024-03-12T22:19:29Z
publishDate 2023-06-01
publisher SpringerOpen
record_format Article
series Journal of Petroleum Exploration and Production Technology
spelling doaj.art-19f209e21a304bf3820d90519a77002c2023-07-23T11:07:27ZengSpringerOpenJournal of Petroleum Exploration and Production Technology2190-05582190-05662023-06-011391951196210.1007/s13202-023-01654-xA novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projectsHamed Rezvani0Yousef Rafiei1Department of Petroleum Engineering, Amirkabir University of TechnologyDepartment of Petroleum Engineering, Amirkabir University of TechnologyAbstract CO2-EOR is one of the principal techniques for enhanced oil recovery (EOR). The CO2 injection not only promotes oil recovery but also leads to greenhouse gas discharge reduction. Nonetheless, a key challenge in the CO2 flooding process is a premature CO2 breakthrough from highly permeable zones. In recent years, Inflow Control Devices, ICDs, have been used as a potential solution to mitigate an early gas breakthrough. The key and important parameter in ICDs installation is obtaining its opening flow area. The common ways to obtain the ICD flow area such as utilizing optimization algorithms are very complicated and time-consuming, and further these methods are not analytical. The aim of this work is to solve the mentioned challenges—postpone the breakthrough time in gas injection and present an easy, fast, and analytical technique for obtaining ICDs flow area. This paper presents a new analytical method for obtaining inflow control devices flow area for injection wells in an oil reservoir under CO2-EOR in order to balance the injected CO2 front movement in all layers. Then, in order to compare the advantages and disadvantages of the presented technique with other methods such as optimization algorithms, a case study has been done on a real reservoir model under CO2 injection. Later, the results of studied scenarios in the case studied are given and compared. The results show that by utilizing the proposed method recovery factor is raised by improving sweep efficiency, and the breakthrough time is more postponed compared to the other methods about 400 days. Further, the ICD flow area calculation takes 2 min by presented analytical techniques, but the optimization algorithm takes 4040 min to run the simulation model to find the ICD flow area. In the end, the findings of the presented analytical formula can help to set the ICD flow area very fast without the simulation and help researchers for a better quantitative understanding of parameters affecting the ICD flow area by the given formula such as reservoir permeability.https://doi.org/10.1007/s13202-023-01654-xCO2-EORInflow control devicesBreakthrough time
spellingShingle Hamed Rezvani
Yousef Rafiei
A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects
Journal of Petroleum Exploration and Production Technology
CO2-EOR
Inflow control devices
Breakthrough time
title A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects
title_full A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects
title_fullStr A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects
title_full_unstemmed A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects
title_short A novel analytical technique for determining inflow control devices flow area in CO2-EOR and CCUS projects
title_sort novel analytical technique for determining inflow control devices flow area in co2 eor and ccus projects
topic CO2-EOR
Inflow control devices
Breakthrough time
url https://doi.org/10.1007/s13202-023-01654-x
work_keys_str_mv AT hamedrezvani anovelanalyticaltechniquefordetermininginflowcontroldevicesflowareainco2eorandccusprojects
AT yousefrafiei anovelanalyticaltechniquefordetermininginflowcontroldevicesflowareainco2eorandccusprojects
AT hamedrezvani novelanalyticaltechniquefordetermininginflowcontroldevicesflowareainco2eorandccusprojects
AT yousefrafiei novelanalyticaltechniquefordetermininginflowcontroldevicesflowareainco2eorandccusprojects