Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study

<i>Background and Objectives:</i> The aim was to compare the Misfit of 3D-Printed, Selective laser melting (SLM), milled (Computer aided design-Computer aided manufacture CAD-CAM) and Lost wax technique (LWT) fabricated Cobalt chromium (CoCr) alloy copings on shoulder (SH), radial should...

Full description

Bibliographic Details
Main Authors: Samar Al-Saleh, Fahim Vohra, Shabab M. Albogami, Nawaf M. Alkhammash, Mohammed A. Alnashwan, Naif S. Almutairi, Khalid A. Aali, Mohammed Alrabiah, Tariq Abduljabbar
Format: Article
Language:English
Published: MDPI AG 2022-09-01
Series:Medicina
Subjects:
Online Access:https://www.mdpi.com/1648-9144/58/10/1313
_version_ 1797471629754761216
author Samar Al-Saleh
Fahim Vohra
Shabab M. Albogami
Nawaf M. Alkhammash
Mohammed A. Alnashwan
Naif S. Almutairi
Khalid A. Aali
Mohammed Alrabiah
Tariq Abduljabbar
author_facet Samar Al-Saleh
Fahim Vohra
Shabab M. Albogami
Nawaf M. Alkhammash
Mohammed A. Alnashwan
Naif S. Almutairi
Khalid A. Aali
Mohammed Alrabiah
Tariq Abduljabbar
author_sort Samar Al-Saleh
collection DOAJ
description <i>Background and Objectives:</i> The aim was to compare the Misfit of 3D-Printed, Selective laser melting (SLM), milled (Computer aided design-Computer aided manufacture CAD-CAM) and Lost wax technique (LWT) fabricated Cobalt chromium (CoCr) alloy copings on shoulder (SH), radial shoulder (R-SH) and chamfer (CH) finish line configuration. <i>Materials and Methods:</i> Ninety resin, second maxillary premolar teeth were prepared for metal-ceramic crowns, equally divided into (<i>n</i> = 30) SH, R-SH and CH margin preparations. For each preparation design (SH, R-SH and CH), CoCr copings were prepared using SLM, CAD-CAM and LWT. This resulted in nine study groups with 10 CoCr copings each. The marginal misfit of specimens was assessed with a high-resolution digital microscope. Misfit was evaluated in vertical and horizontal dimensions in μm. Data were analyzed using ANOVA and a post hoc multiple comparisons test. <i>Results:</i> For vertical misfit, the highest was observed in SLM samples with chamfer margin (167.96 ± 24.1), and the least was shown by CAD-CAM samples with radial shoulder (58.8 ± 12.53). CAD-CAM and shoulder margins showed the least vertical misfit. For horizontal misfit, the maximum was observed in SLM samples with shoulder margin (137.94 ± 37.85) and the least by LWT samples with chamfer (89.38 ± 14.81). Chamfer margins and LWT samples showed the least horizontal misfit among the group samples. Fabrication technique and finish line design play a critical role in reducing the marginal misfit of CoCr copings. <i>Conclusions:</i> For vertical misfit, SLM copings showed poor outcomes compared to CAD-CAM specimens, however comparable outcomes to Cast specimens. SLM copings showed comparable horizontal misfit outcomes to CAD-CAM specimens and low misfit compared to Cast copings, respectively. Vertical misfit was low with shoulder margins, and horizontal misfit was better with chamfer marginal configuration.
first_indexed 2024-03-09T19:50:55Z
format Article
id doaj.art-1a022aa9b4604e1db12fecbab2999842
institution Directory Open Access Journal
issn 1010-660X
1648-9144
language English
last_indexed 2024-03-09T19:50:55Z
publishDate 2022-09-01
publisher MDPI AG
record_format Article
series Medicina
spelling doaj.art-1a022aa9b4604e1db12fecbab29998422023-11-24T01:08:58ZengMDPI AGMedicina1010-660X1648-91442022-09-015810131310.3390/medicina58101313Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro StudySamar Al-Saleh0Fahim Vohra1Shabab M. Albogami2Nawaf M. Alkhammash3Mohammed A. Alnashwan4Naif S. Almutairi5Khalid A. Aali6Mohammed Alrabiah7Tariq Abduljabbar8Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of General Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of General Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of General Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of General Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi ArabiaDepartment of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia<i>Background and Objectives:</i> The aim was to compare the Misfit of 3D-Printed, Selective laser melting (SLM), milled (Computer aided design-Computer aided manufacture CAD-CAM) and Lost wax technique (LWT) fabricated Cobalt chromium (CoCr) alloy copings on shoulder (SH), radial shoulder (R-SH) and chamfer (CH) finish line configuration. <i>Materials and Methods:</i> Ninety resin, second maxillary premolar teeth were prepared for metal-ceramic crowns, equally divided into (<i>n</i> = 30) SH, R-SH and CH margin preparations. For each preparation design (SH, R-SH and CH), CoCr copings were prepared using SLM, CAD-CAM and LWT. This resulted in nine study groups with 10 CoCr copings each. The marginal misfit of specimens was assessed with a high-resolution digital microscope. Misfit was evaluated in vertical and horizontal dimensions in μm. Data were analyzed using ANOVA and a post hoc multiple comparisons test. <i>Results:</i> For vertical misfit, the highest was observed in SLM samples with chamfer margin (167.96 ± 24.1), and the least was shown by CAD-CAM samples with radial shoulder (58.8 ± 12.53). CAD-CAM and shoulder margins showed the least vertical misfit. For horizontal misfit, the maximum was observed in SLM samples with shoulder margin (137.94 ± 37.85) and the least by LWT samples with chamfer (89.38 ± 14.81). Chamfer margins and LWT samples showed the least horizontal misfit among the group samples. Fabrication technique and finish line design play a critical role in reducing the marginal misfit of CoCr copings. <i>Conclusions:</i> For vertical misfit, SLM copings showed poor outcomes compared to CAD-CAM specimens, however comparable outcomes to Cast specimens. SLM copings showed comparable horizontal misfit outcomes to CAD-CAM specimens and low misfit compared to Cast copings, respectively. Vertical misfit was low with shoulder margins, and horizontal misfit was better with chamfer marginal configuration.https://www.mdpi.com/1648-9144/58/10/1313misfitmarginal openinglost wax techniqueselective laser meltingCAD-CAM
spellingShingle Samar Al-Saleh
Fahim Vohra
Shabab M. Albogami
Nawaf M. Alkhammash
Mohammed A. Alnashwan
Naif S. Almutairi
Khalid A. Aali
Mohammed Alrabiah
Tariq Abduljabbar
Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study
Medicina
misfit
marginal opening
lost wax technique
selective laser melting
CAD-CAM
title Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study
title_full Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study
title_fullStr Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study
title_full_unstemmed Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study
title_short Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study
title_sort marginal misfit of 3d printed selective laser sintered cad cam and lost wax technique cobalt chromium copings with shoulder and chamfer finish lines an in vitro study
topic misfit
marginal opening
lost wax technique
selective laser melting
CAD-CAM
url https://www.mdpi.com/1648-9144/58/10/1313
work_keys_str_mv AT samaralsaleh marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT fahimvohra marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT shababmalbogami marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT nawafmalkhammash marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT mohammedaalnashwan marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT naifsalmutairi marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT khalidaaali marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT mohammedalrabiah marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy
AT tariqabduljabbar marginalmisfitof3dprintedselectivelasersinteredcadcamandlostwaxtechniquecobaltchromiumcopingswithshoulderandchamferfinishlinesaninvitrostudy