STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES

Electric energy has been transmiting from power station to end user with transmission and distribution lines.Lightning strokes are problems that occure in transmission and distribution lines and make them fault when theelectric energy were transmited. Surge Diverter or Lightning Arrester has been in...

Full description

Bibliographic Details
Main Authors: Agung Warsito, Abdul Syakur, Liliyana N.S.
Format: Article
Language:English
Published: Diponegoro University 2012-02-01
Series:Teknik
Subjects:
Online Access:http://ejournal.undip.ac.id/index.php/teknik/article/view/1886
_version_ 1818732782514339840
author Agung Warsito
Abdul Syakur
Liliyana N.S.
author_facet Agung Warsito
Abdul Syakur
Liliyana N.S.
author_sort Agung Warsito
collection DOAJ
description Electric energy has been transmiting from power station to end user with transmission and distribution lines.Lightning strokes are problems that occure in transmission and distribution lines and make them fault when theelectric energy were transmited. Surge Diverter or Lightning Arrester has been installing to reduce these faults.In this paper the simulation of lightning stroke and lightning arrester performance on distribution lines 20 kVwere done using EMTP (Electromagnetic Transient Program). Some parameters such us impuls voltage andincreasing voltage on distribution line was inverstigated. As case study in this simulation, Mojosongo 1 mainfeeder 20 kV three phase lines were used.The simulation results show that the lightning stroke 20 kA in By1-61-61E-84-9I on S phase at 0,1 ms, makevoltage on S phase was increased about 1,3054 MV. For R phase and T phase will increase of induced voltagewere 0.79539 MV and 0.80484 MV. We also show the performance of MOV Arrester (Metal Oxide Varistor) inovercoming lightning stroke trouble, where arrester can decrease voltage up to 15.198 kV on S phase, while atR phase and T phase arrester can decrease voltage up to 11.375 kV and 13.616 kV.
first_indexed 2024-12-17T23:39:03Z
format Article
id doaj.art-1a77ea392a7c470c84e9084642f55660
institution Directory Open Access Journal
issn 0852-1697
2460-9919
language English
last_indexed 2024-12-17T23:39:03Z
publishDate 2012-02-01
publisher Diponegoro University
record_format Article
series Teknik
spelling doaj.art-1a77ea392a7c470c84e9084642f556602022-12-21T21:28:29ZengDiponegoro UniversityTeknik0852-16972460-99192012-02-013031711771573STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINESAgung WarsitoAbdul SyakurLiliyana N.S.Electric energy has been transmiting from power station to end user with transmission and distribution lines.Lightning strokes are problems that occure in transmission and distribution lines and make them fault when theelectric energy were transmited. Surge Diverter or Lightning Arrester has been installing to reduce these faults.In this paper the simulation of lightning stroke and lightning arrester performance on distribution lines 20 kVwere done using EMTP (Electromagnetic Transient Program). Some parameters such us impuls voltage andincreasing voltage on distribution line was inverstigated. As case study in this simulation, Mojosongo 1 mainfeeder 20 kV three phase lines were used.The simulation results show that the lightning stroke 20 kA in By1-61-61E-84-9I on S phase at 0,1 ms, makevoltage on S phase was increased about 1,3054 MV. For R phase and T phase will increase of induced voltagewere 0.79539 MV and 0.80484 MV. We also show the performance of MOV Arrester (Metal Oxide Varistor) inovercoming lightning stroke trouble, where arrester can decrease voltage up to 15.198 kV on S phase, while atR phase and T phase arrester can decrease voltage up to 11.375 kV and 13.616 kV.http://ejournal.undip.ac.id/index.php/teknik/article/view/1886Distribution lines 20 kV, surge arrester, lightning stroke.
spellingShingle Agung Warsito
Abdul Syakur
Liliyana N.S.
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
Teknik
Distribution lines 20 kV, surge arrester, lightning stroke.
title STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
title_full STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
title_fullStr STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
title_full_unstemmed STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
title_short STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
title_sort study on surge arrester performance due to lightning stroke in 20 kv distribution lines
topic Distribution lines 20 kV, surge arrester, lightning stroke.
url http://ejournal.undip.ac.id/index.php/teknik/article/view/1886
work_keys_str_mv AT agungwarsito studyonsurgearresterperformanceduetolightningstrokein20kvdistributionlines
AT abdulsyakur studyonsurgearresterperformanceduetolightningstrokein20kvdistributionlines
AT liliyanans studyonsurgearresterperformanceduetolightningstrokein20kvdistributionlines