Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation

This paper presents an exoskeleton for upper extremity rehabilitation of stroke patients. In order to make rehabilitation widely available, the goal is an inexpensive, portable, and easy-to-use therapy for paralysis of the arm. The exoskeleton is actuated by twisted string actuators (TSA). To reduce...

Full description

Bibliographic Details
Main Authors: Weymann Sylvia, Pretty Chris G., Pott Peter P.
Format: Article
Language:English
Published: De Gruyter 2022-09-01
Series:Current Directions in Biomedical Engineering
Subjects:
Online Access:https://doi.org/10.1515/cdbme-2022-1141
_version_ 1811159413893890048
author Weymann Sylvia
Pretty Chris G.
Pott Peter P.
author_facet Weymann Sylvia
Pretty Chris G.
Pott Peter P.
author_sort Weymann Sylvia
collection DOAJ
description This paper presents an exoskeleton for upper extremity rehabilitation of stroke patients. In order to make rehabilitation widely available, the goal is an inexpensive, portable, and easy-to-use therapy for paralysis of the arm. The exoskeleton is actuated by twisted string actuators (TSA). To reduce the length of the TSA a motor with hollow shaft was chosen, as this allows the string to run through the motor. The control of the exoskeleton is designed for predefined elbow flexion exercises. The start of the movement is triggered by a threshold value in the sEMG of the m. biceps brachii. To evaluate the controller, the exoskeleton performed a flexion movement (5° to 115°) in 2 s and then an extension back to 5° in the same time after a 1 s wait. To simulate different force requirements, additional weights up to 1500 g were attached. During both, the flexion and extension movement, that angle tracking error was sufficiently small and the steady state error was zero. The angular velocity of the elbow joint showed pronounced oscillations with increasing weights. The results show that TSAs can be used to actuate elbow exoskeletons. Thus lightweight, ergonomic, simple and small rehabilitation devices can now be built on this basis. The elasticity of the system must be considered in future work. sEMG must be further implemented to control more sophisticated functions of the rehabilitation device.
first_indexed 2024-04-10T05:40:39Z
format Article
id doaj.art-1b231af6ab534256965b5b1257243dbd
institution Directory Open Access Journal
issn 2364-5504
language English
last_indexed 2024-04-10T05:40:39Z
publishDate 2022-09-01
publisher De Gruyter
record_format Article
series Current Directions in Biomedical Engineering
spelling doaj.art-1b231af6ab534256965b5b1257243dbd2023-03-06T10:24:52ZengDe GruyterCurrent Directions in Biomedical Engineering2364-55042022-09-018255255510.1515/cdbme-2022-1141Development of an EMG-based Elbow- Exoskeleton with Twisted String ActuationWeymann Sylvia0Pretty Chris G.1Pott Peter P.2Institute of Medical Device Technology, University of Stuttgart, Pfaffenwaldring 9, 70569Stuttgart, GermanyDepartment of Mechanical Engineering, University of Canterbury,Christchurch, New ZealandInstitute of Medical Device Technology, University of Stuttgart, 70569Stuttgart, GermanyThis paper presents an exoskeleton for upper extremity rehabilitation of stroke patients. In order to make rehabilitation widely available, the goal is an inexpensive, portable, and easy-to-use therapy for paralysis of the arm. The exoskeleton is actuated by twisted string actuators (TSA). To reduce the length of the TSA a motor with hollow shaft was chosen, as this allows the string to run through the motor. The control of the exoskeleton is designed for predefined elbow flexion exercises. The start of the movement is triggered by a threshold value in the sEMG of the m. biceps brachii. To evaluate the controller, the exoskeleton performed a flexion movement (5° to 115°) in 2 s and then an extension back to 5° in the same time after a 1 s wait. To simulate different force requirements, additional weights up to 1500 g were attached. During both, the flexion and extension movement, that angle tracking error was sufficiently small and the steady state error was zero. The angular velocity of the elbow joint showed pronounced oscillations with increasing weights. The results show that TSAs can be used to actuate elbow exoskeletons. Thus lightweight, ergonomic, simple and small rehabilitation devices can now be built on this basis. The elasticity of the system must be considered in future work. sEMG must be further implemented to control more sophisticated functions of the rehabilitation device.https://doi.org/10.1515/cdbme-2022-1141elbow-exoskeletonemgtwisted string actuationstrokerehabilitationactive orthosis
spellingShingle Weymann Sylvia
Pretty Chris G.
Pott Peter P.
Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation
Current Directions in Biomedical Engineering
elbow-exoskeleton
emg
twisted string actuation
stroke
rehabilitation
active orthosis
title Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation
title_full Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation
title_fullStr Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation
title_full_unstemmed Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation
title_short Development of an EMG-based Elbow- Exoskeleton with Twisted String Actuation
title_sort development of an emg based elbow exoskeleton with twisted string actuation
topic elbow-exoskeleton
emg
twisted string actuation
stroke
rehabilitation
active orthosis
url https://doi.org/10.1515/cdbme-2022-1141
work_keys_str_mv AT weymannsylvia developmentofanemgbasedelbowexoskeletonwithtwistedstringactuation
AT prettychrisg developmentofanemgbasedelbowexoskeletonwithtwistedstringactuation
AT pottpeterp developmentofanemgbasedelbowexoskeletonwithtwistedstringactuation