Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links

The multi-infeed interaction factor (MIIF) is used extensively in indicating the degree of interaction among high-voltage direct current (HVDC) converters and is currently calculated by simulation methods according to the definition, or by using the equivalent impedance ratio method. The first metho...

Full description

Bibliographic Details
Main Authors: Chengjun Xia, Xia Hua, Zhen Wang, Zhenlin Huang
Format: Article
Language:English
Published: MDPI AG 2018-06-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/11/6/1506
_version_ 1811280703666520064
author Chengjun Xia
Xia Hua
Zhen Wang
Zhenlin Huang
author_facet Chengjun Xia
Xia Hua
Zhen Wang
Zhenlin Huang
author_sort Chengjun Xia
collection DOAJ
description The multi-infeed interaction factor (MIIF) is used extensively in indicating the degree of interaction among high-voltage direct current (HVDC) converters and is currently calculated by simulation methods according to the definition, or by using the equivalent impedance ratio method. The first method is an experimental calculation method and the second method does not account for the effects of HVDC control modes. An analytical calculation method for MIIF considering control modes of HVDC links is proposed in this paper. First, the voltage variation of converter bus in the context of small disturbance is equated by using the bus impedance matrix. In this way the equations for the solution of MIIF considering HVDC control mode are obtained. Subsequently, based on two rational assumptions, the practical analytical calculation expression of MIIF is deduced in detail. The MIIF calculation method proposed in this paper is an improvement of the equivalent impedance ratio method and reflects the main influencing factors of voltage interaction including HVDC control modes. Moreover, the derived analytical expression can give a fundamental insight into parameter dependencies of voltage interaction. Finally, the validity and accuracy of the proposed approach are demonstrated in both dual-infeed HVDC system and actual large-scale power grid.
first_indexed 2024-04-13T01:19:33Z
format Article
id doaj.art-1b6a010969ed4616877b926c43a87dc9
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-13T01:19:33Z
publishDate 2018-06-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-1b6a010969ed4616877b926c43a87dc92022-12-22T03:08:48ZengMDPI AGEnergies1996-10732018-06-01116150610.3390/en11061506en11061506Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current LinksChengjun Xia0Xia Hua1Zhen Wang2Zhenlin Huang3School of Electric Power, South China University of Technology, Guangzhou 510640, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510640, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510640, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510640, ChinaThe multi-infeed interaction factor (MIIF) is used extensively in indicating the degree of interaction among high-voltage direct current (HVDC) converters and is currently calculated by simulation methods according to the definition, or by using the equivalent impedance ratio method. The first method is an experimental calculation method and the second method does not account for the effects of HVDC control modes. An analytical calculation method for MIIF considering control modes of HVDC links is proposed in this paper. First, the voltage variation of converter bus in the context of small disturbance is equated by using the bus impedance matrix. In this way the equations for the solution of MIIF considering HVDC control mode are obtained. Subsequently, based on two rational assumptions, the practical analytical calculation expression of MIIF is deduced in detail. The MIIF calculation method proposed in this paper is an improvement of the equivalent impedance ratio method and reflects the main influencing factors of voltage interaction including HVDC control modes. Moreover, the derived analytical expression can give a fundamental insight into parameter dependencies of voltage interaction. Finally, the validity and accuracy of the proposed approach are demonstrated in both dual-infeed HVDC system and actual large-scale power grid.http://www.mdpi.com/1996-1073/11/6/1506multi-infeed interaction factor (MIIF)AC/DC hybrid power systemequivalent impedanceHVDC control mode
spellingShingle Chengjun Xia
Xia Hua
Zhen Wang
Zhenlin Huang
Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
Energies
multi-infeed interaction factor (MIIF)
AC/DC hybrid power system
equivalent impedance
HVDC control mode
title Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
title_full Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
title_fullStr Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
title_full_unstemmed Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
title_short Analytical Calculation for Multi-Infeed Interaction Factors Considering Control Modes of High Voltage Direct Current Links
title_sort analytical calculation for multi infeed interaction factors considering control modes of high voltage direct current links
topic multi-infeed interaction factor (MIIF)
AC/DC hybrid power system
equivalent impedance
HVDC control mode
url http://www.mdpi.com/1996-1073/11/6/1506
work_keys_str_mv AT chengjunxia analyticalcalculationformultiinfeedinteractionfactorsconsideringcontrolmodesofhighvoltagedirectcurrentlinks
AT xiahua analyticalcalculationformultiinfeedinteractionfactorsconsideringcontrolmodesofhighvoltagedirectcurrentlinks
AT zhenwang analyticalcalculationformultiinfeedinteractionfactorsconsideringcontrolmodesofhighvoltagedirectcurrentlinks
AT zhenlinhuang analyticalcalculationformultiinfeedinteractionfactorsconsideringcontrolmodesofhighvoltagedirectcurrentlinks