Angular deflection of rotary nickel titanium files: a comparative study

A new manufacturing method of twisting nickel titanium wire to produce rotary nickel titanium (RNT) files has recently been developed. The aim of the present study was to evaluate whether the new manufacturing process increased the angular deflection of RNT files, by comparing instruments produced u...

Full description

Bibliographic Details
Main Authors: Gianluca Gambarini, Luca Testarelli, Valerio Milana, Raffaella Pecci, Rossella Bedini, Giancarlo Pongione, Roberto Gerosa, Massimo De Luca
Format: Article
Language:English
Published: Istituto Superiore di Sanità 2009-12-01
Series:Annali dell'Istituto Superiore di Sanità
Subjects:
Online Access:http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712009000400011&lng=en&tlng=en
_version_ 1811337121172029440
author Gianluca Gambarini
Luca Testarelli
Valerio Milana
Raffaella Pecci
Rossella Bedini
Giancarlo Pongione
Roberto Gerosa
Massimo De Luca
author_facet Gianluca Gambarini
Luca Testarelli
Valerio Milana
Raffaella Pecci
Rossella Bedini
Giancarlo Pongione
Roberto Gerosa
Massimo De Luca
author_sort Gianluca Gambarini
collection DOAJ
description A new manufacturing method of twisting nickel titanium wire to produce rotary nickel titanium (RNT) files has recently been developed. The aim of the present study was to evaluate whether the new manufacturing process increased the angular deflection of RNT files, by comparing instruments produced using the new manufacturing method (Twisted Files) versus instruments produced with the traditional grinding process. Testing was performed on a total of 40 instruments of the following commercially available RNT files: Twisted Files (TF), Profile, K3 and M2 (NRT). All instruments tested had the same dimensions (taper 0.06 and tip size 25). Test procedures strictly followed ISO 3630-1. Data were collected and statistically analyzed by means ANOVA test. The results showed that TF demonstrated significantly higher average angular deflection levels (P<0.05), than RNT manufactured by a grinding process. Since angular deflection represent the amount of rotation (and consequently deformation) that a RNT file can withstand before torsional failure, such a significant improvement is a favorable property for the clinical use of the tested RNT files.
first_indexed 2024-04-13T17:50:20Z
format Article
id doaj.art-1b798bb9c4e649f599f583233425840d
institution Directory Open Access Journal
issn 0021-2571
language English
last_indexed 2024-04-13T17:50:20Z
publishDate 2009-12-01
publisher Istituto Superiore di Sanità
record_format Article
series Annali dell'Istituto Superiore di Sanità
spelling doaj.art-1b798bb9c4e649f599f583233425840d2022-12-22T02:36:44ZengIstituto Superiore di SanitàAnnali dell'Istituto Superiore di Sanità0021-25712009-12-0145442342610.1590/s0021-25712009000400011S0021-25712009000400011Angular deflection of rotary nickel titanium files: a comparative studyGianluca Gambarini0Luca Testarelli1Valerio Milana2Raffaella Pecci3Rossella Bedini4Giancarlo Pongione5Roberto Gerosa6Massimo De LucaUniversità degli Studi SapienzaUniversità degli Studi SapienzaIstituto Superiore di SanitàIstituto Superiore di SanitàIstituto Superiore di SanitàUniversità degli Studi SapienzaUniversità degli StudiA new manufacturing method of twisting nickel titanium wire to produce rotary nickel titanium (RNT) files has recently been developed. The aim of the present study was to evaluate whether the new manufacturing process increased the angular deflection of RNT files, by comparing instruments produced using the new manufacturing method (Twisted Files) versus instruments produced with the traditional grinding process. Testing was performed on a total of 40 instruments of the following commercially available RNT files: Twisted Files (TF), Profile, K3 and M2 (NRT). All instruments tested had the same dimensions (taper 0.06 and tip size 25). Test procedures strictly followed ISO 3630-1. Data were collected and statistically analyzed by means ANOVA test. The results showed that TF demonstrated significantly higher average angular deflection levels (P<0.05), than RNT manufactured by a grinding process. Since angular deflection represent the amount of rotation (and consequently deformation) that a RNT file can withstand before torsional failure, such a significant improvement is a favorable property for the clinical use of the tested RNT files.http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712009000400011&lng=en&tlng=ennickel titaniodeflessione angolareendodonzia
spellingShingle Gianluca Gambarini
Luca Testarelli
Valerio Milana
Raffaella Pecci
Rossella Bedini
Giancarlo Pongione
Roberto Gerosa
Massimo De Luca
Angular deflection of rotary nickel titanium files: a comparative study
Annali dell'Istituto Superiore di Sanità
nickel titanio
deflessione angolare
endodonzia
title Angular deflection of rotary nickel titanium files: a comparative study
title_full Angular deflection of rotary nickel titanium files: a comparative study
title_fullStr Angular deflection of rotary nickel titanium files: a comparative study
title_full_unstemmed Angular deflection of rotary nickel titanium files: a comparative study
title_short Angular deflection of rotary nickel titanium files: a comparative study
title_sort angular deflection of rotary nickel titanium files a comparative study
topic nickel titanio
deflessione angolare
endodonzia
url http://www.scielosp.org/scielo.php?script=sci_arttext&pid=S0021-25712009000400011&lng=en&tlng=en
work_keys_str_mv AT gianlucagambarini angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT lucatestarelli angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT valeriomilana angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT raffaellapecci angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT rossellabedini angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT giancarlopongione angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT robertogerosa angulardeflectionofrotarynickeltitaniumfilesacomparativestudy
AT massimodeluca angulardeflectionofrotarynickeltitaniumfilesacomparativestudy