Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault

The aim of the paper is theoretical and experimental research of processes during the single-phase ground faults in electrical distribution grids of 10/06/35 kV with isolated neutral mode. The mathematical method of rationing is used for the analysis of the spectral composition of currents and volta...

Full description

Bibliographic Details
Main Authors: A. I. Fedotov, L. V. Akhmetvaleeva, R. S. Basyrov, G. V. Vagapov, E. A. Fedotov
Format: Article
Language:English
Published: Kazan State Power Engineering University 2020-04-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1285
_version_ 1797762173554917376
author A. I. Fedotov
L. V. Akhmetvaleeva
R. S. Basyrov
G. V. Vagapov
E. A. Fedotov
author_facet A. I. Fedotov
L. V. Akhmetvaleeva
R. S. Basyrov
G. V. Vagapov
E. A. Fedotov
author_sort A. I. Fedotov
collection DOAJ
description The aim of the paper is theoretical and experimental research of processes during the single-phase ground faults in electrical distribution grids of 10/06/35 kV with isolated neutral mode. The mathematical method of rationing is used for the analysis of the spectral composition of currents and voltages increasing the information content of the allocated higher harmonics of current and voltage. The paper show a comparison of the results of spectral analysis with and without taking into account the mathematical rationing obtained on the simulation model. Field experiments have demonstrated the effectiveness of using of the method of mathematical rationing of the higher harmonic components of current and voltage for various types of single-phase ground faults. The results of field experiments provided an opportunity of improving the methodology of yearling detection of single-phase ground faults in electric grids of 6-10-35 kV with an isolated mode of neutral. The conclusion of the research is the possibility of a significantly more accurate selection of the resonant frequencies of the spectrum of currents and voltages obtained by using of the method of mathematical rationing. The possibility of earlier and more precise localization of the feeder with ground fault is shown on the base more precise selection of the resonant frequency currents and voltages.
first_indexed 2024-03-12T19:23:29Z
format Article
id doaj.art-1b9ccb22be424b6ebdac7782fb60b1fe
institution Directory Open Access Journal
issn 1998-9903
language English
last_indexed 2024-03-12T19:23:29Z
publishDate 2020-04-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj.art-1b9ccb22be424b6ebdac7782fb60b1fe2023-08-02T04:57:44ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032020-04-01221586810.30724/1998-9903-2020-22-1-58-68646Rating of amplitudes of high harmonics in determining feeder with single-phase ground faultA. I. Fedotov0L. V. Akhmetvaleeva1R. S. Basyrov2G. V. Vagapov3E. A. Fedotov4Kazan State Power Engineering UniversityKazan State Power Engineering UniversityKazan National Research Technical UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityThe aim of the paper is theoretical and experimental research of processes during the single-phase ground faults in electrical distribution grids of 10/06/35 kV with isolated neutral mode. The mathematical method of rationing is used for the analysis of the spectral composition of currents and voltages increasing the information content of the allocated higher harmonics of current and voltage. The paper show a comparison of the results of spectral analysis with and without taking into account the mathematical rationing obtained on the simulation model. Field experiments have demonstrated the effectiveness of using of the method of mathematical rationing of the higher harmonic components of current and voltage for various types of single-phase ground faults. The results of field experiments provided an opportunity of improving the methodology of yearling detection of single-phase ground faults in electric grids of 6-10-35 kV with an isolated mode of neutral. The conclusion of the research is the possibility of a significantly more accurate selection of the resonant frequencies of the spectrum of currents and voltages obtained by using of the method of mathematical rationing. The possibility of earlier and more precise localization of the feeder with ground fault is shown on the base more precise selection of the resonant frequency currents and voltages.https://www.energyret.ru/jour/article/view/1285higher harmonics of current and voltagesingle-phase ground fault
spellingShingle A. I. Fedotov
L. V. Akhmetvaleeva
R. S. Basyrov
G. V. Vagapov
E. A. Fedotov
Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault
Известия высших учебных заведений: Проблемы энергетики
higher harmonics of current and voltage
single-phase ground fault
title Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault
title_full Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault
title_fullStr Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault
title_full_unstemmed Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault
title_short Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault
title_sort rating of amplitudes of high harmonics in determining feeder with single phase ground fault
topic higher harmonics of current and voltage
single-phase ground fault
url https://www.energyret.ru/jour/article/view/1285
work_keys_str_mv AT aifedotov ratingofamplitudesofhighharmonicsindeterminingfeederwithsinglephasegroundfault
AT lvakhmetvaleeva ratingofamplitudesofhighharmonicsindeterminingfeederwithsinglephasegroundfault
AT rsbasyrov ratingofamplitudesofhighharmonicsindeterminingfeederwithsinglephasegroundfault
AT gvvagapov ratingofamplitudesofhighharmonicsindeterminingfeederwithsinglephasegroundfault
AT eafedotov ratingofamplitudesofhighharmonicsindeterminingfeederwithsinglephasegroundfault