The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures
The paper considers the problem of adjusting the power of a nuclear power plant power unit reactor for those cases when equipment failure occurs. In such circumstances, sometimes it is sufficient to reduce the reactor power, while maintaining the probabilistic level of safe operation of the power un...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
NAS of Ukraine, A. Pidhornyi Institute of Mechanical Engineering Problems
2022-09-01
|
Series: | Journal of Mechanical Engineering |
Subjects: |
_version_ | 1811224220291563520 |
---|---|
author | Andrii O. Kostikov Leonid I. Zevin Hennadii H. Krol Anna L. Vorontsova |
author_facet | Andrii O. Kostikov Leonid I. Zevin Hennadii H. Krol Anna L. Vorontsova |
author_sort | Andrii O. Kostikov |
collection | DOAJ |
description | The paper considers the problem of adjusting the power of a nuclear power plant power unit reactor for those cases when equipment failure occurs. In such circumstances, sometimes it is sufficient to reduce the reactor power, while maintaining the probabilistic level of safe operation of the power unit. The rational number of the reactor power is determined by solving the problem of minimizing the risk criterion in the integral root mean square context. In order to demonstrate the efficiency of the proposed approach, a numerical example is considered. The approach outlined in the paper is focused on improving the power unit control in case of equipment failures. |
first_indexed | 2024-04-12T08:44:45Z |
format | Article |
id | doaj.art-1bd0ec520cc34bb8adc902eaccfc7393 |
institution | Directory Open Access Journal |
issn | 2709-2984 2709-2992 |
language | English |
last_indexed | 2024-04-12T08:44:45Z |
publishDate | 2022-09-01 |
publisher | NAS of Ukraine, A. Pidhornyi Institute of Mechanical Engineering Problems |
record_format | Article |
series | Journal of Mechanical Engineering |
spelling | doaj.art-1bd0ec520cc34bb8adc902eaccfc73932022-12-22T03:39:44ZengNAS of Ukraine, A. Pidhornyi Institute of Mechanical Engineering ProblemsJournal of Mechanical Engineering2709-29842709-29922022-09-01253404510.15407/pmach2022.03.040The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment FailuresAndrii O. Kostikov0https://orcid.org/0000-0001-6076-1942Leonid I. Zevin1Hennadii H. Krol2Anna L. Vorontsova3A. Pidhornyi Institute of Mechanical Engineering Problems of NASUA. Pidhornyi Institute of Mechanical Engineering Problems of NASUA. Pidhornyi Institute of Mechanical Engineering Problems of NASUA. Pidhornyi Institute of Mechanical Engineering Problems of NASUThe paper considers the problem of adjusting the power of a nuclear power plant power unit reactor for those cases when equipment failure occurs. In such circumstances, sometimes it is sufficient to reduce the reactor power, while maintaining the probabilistic level of safe operation of the power unit. The rational number of the reactor power is determined by solving the problem of minimizing the risk criterion in the integral root mean square context. In order to demonstrate the efficiency of the proposed approach, a numerical example is considered. The approach outlined in the paper is focused on improving the power unit control in case of equipment failures.nuclear power plantpower unitsafetyriskpowerfailure |
spellingShingle | Andrii O. Kostikov Leonid I. Zevin Hennadii H. Krol Anna L. Vorontsova The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures Journal of Mechanical Engineering nuclear power plant power unit safety risk power failure |
title | The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures |
title_full | The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures |
title_fullStr | The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures |
title_full_unstemmed | The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures |
title_short | The Optimal Correcting the Power Value of a Nuclear Power Plant Power Unit Reactor in the Event of Equipment Failures |
title_sort | optimal correcting the power value of a nuclear power plant power unit reactor in the event of equipment failures |
topic | nuclear power plant power unit safety risk power failure |
work_keys_str_mv | AT andriiokostikov theoptimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT leonidizevin theoptimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT hennadiihkrol theoptimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT annalvorontsova theoptimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT andriiokostikov optimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT leonidizevin optimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT hennadiihkrol optimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures AT annalvorontsova optimalcorrectingthepowervalueofanuclearpowerplantpowerunitreactorintheeventofequipmentfailures |