Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment

Combustion air humidification has proven to be effective to stabilize hydrogen combustion and to avoid flashback apparition in a typical micro Gas Turbine (mGT). However, both the fuel alteration and combustion air dilution will impact the cycle performance. A complete characterization of this therm...

Full description

Bibliographic Details
Main Authors: Pappa Alessio, De Paepe Ward
Format: Article
Language:English
Published: EDP Sciences 2023-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/51/e3sconf_supehr2023_03010.pdf
_version_ 1797736054853206016
author Pappa Alessio
De Paepe Ward
author_facet Pappa Alessio
De Paepe Ward
author_sort Pappa Alessio
collection DOAJ
description Combustion air humidification has proven to be effective to stabilize hydrogen combustion and to avoid flashback apparition in a typical micro Gas Turbine (mGT). However, both the fuel alteration and combustion air dilution will impact the cycle performance. A complete characterization of this thermodynamic impact is essential to ensure that the mGTs become cleaner, and fully flexible to fit with the expectation of future small-scale decentralized power production. Therefore, the objective of this work is twofold: the determination of the necessary dilution for combustion stabilization, depending on the type of fuel, as well as the impact assessment on the cycle performance. In this framework, a hybrid model of the Turbec T100 mGT combustor, combining a 0D Chemical Reactor Network and 1D Laminar flame calculations, is used to first assess the flashback limits. The laminar flame speed is evaluated to predetermine the necessary minimal water dilution of the combustion air to avoid flashback for several CH4/H2 blends. Second, a thermodynamic analysis is performed to assess the impact of the flame stabilization measures on the cycle performance of the mGT using Aspen Plus. The 0D/1D simulation results show that the combustor of the Turbec T100 can operate with fuels containing up to 100% hydrogen. However, the thermodynamic analysis shows that the water dilution leads to a decreased electrical performance. Future work consists in the iterative coupling of both 0D/1D and the Aspen model to correctly predict the flashback limits, considering the altering operating conditions. To conclude, with this work, we provide a framework for future mGT operations with alternative fuels.
first_indexed 2024-03-12T13:08:03Z
format Article
id doaj.art-1bf935fdb07242fa996d0f5641d7c0ef
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-03-12T13:08:03Z
publishDate 2023-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-1bf935fdb07242fa996d0f5641d7c0ef2023-08-28T12:27:56ZengEDP SciencesE3S Web of Conferences2267-12422023-01-014140301010.1051/e3sconf/202341403010e3sconf_supehr2023_03010Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance AssessmentPappa Alessio0De Paepe Ward1University of Mons (UMONS)University of Mons (UMONS)Combustion air humidification has proven to be effective to stabilize hydrogen combustion and to avoid flashback apparition in a typical micro Gas Turbine (mGT). However, both the fuel alteration and combustion air dilution will impact the cycle performance. A complete characterization of this thermodynamic impact is essential to ensure that the mGTs become cleaner, and fully flexible to fit with the expectation of future small-scale decentralized power production. Therefore, the objective of this work is twofold: the determination of the necessary dilution for combustion stabilization, depending on the type of fuel, as well as the impact assessment on the cycle performance. In this framework, a hybrid model of the Turbec T100 mGT combustor, combining a 0D Chemical Reactor Network and 1D Laminar flame calculations, is used to first assess the flashback limits. The laminar flame speed is evaluated to predetermine the necessary minimal water dilution of the combustion air to avoid flashback for several CH4/H2 blends. Second, a thermodynamic analysis is performed to assess the impact of the flame stabilization measures on the cycle performance of the mGT using Aspen Plus. The 0D/1D simulation results show that the combustor of the Turbec T100 can operate with fuels containing up to 100% hydrogen. However, the thermodynamic analysis shows that the water dilution leads to a decreased electrical performance. Future work consists in the iterative coupling of both 0D/1D and the Aspen model to correctly predict the flashback limits, considering the altering operating conditions. To conclude, with this work, we provide a framework for future mGT operations with alternative fuels.https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/51/e3sconf_supehr2023_03010.pdf
spellingShingle Pappa Alessio
De Paepe Ward
Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment
E3S Web of Conferences
title Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment
title_full Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment
title_fullStr Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment
title_full_unstemmed Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment
title_short Humidification Towards Flashback Prevention in a Classical Micro Gas Turbine: Thermodynamic Performance Assessment
title_sort humidification towards flashback prevention in a classical micro gas turbine thermodynamic performance assessment
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2023/51/e3sconf_supehr2023_03010.pdf
work_keys_str_mv AT pappaalessio humidificationtowardsflashbackpreventioninaclassicalmicrogasturbinethermodynamicperformanceassessment
AT depaepeward humidificationtowardsflashbackpreventioninaclassicalmicrogasturbinethermodynamicperformanceassessment