Stationary and mobile particulate matter concentration measurement in Miskolc

A stationary and mobile device based on a low-cost dust sensor (Plantower PMS7003) was used to study particulate matter (PM) concentration in Miskolc. The stationary device was placed at the automatic monitoring station of the National Air Quality Measurement Network (OLM) in Martintelep, Miskolc....

Full description

Bibliographic Details
Main Authors: Csongor Báthory, Péter Pecsmány, Lajos Szalontai, Árpád Bence Palotás
Format: Article
Language:English
Published: Faculty of Engineering, University of Debrecen 2019-12-01
Series:International Journal of Engineering and Management Sciences
Online Access:https://ojs.lib.unideb.hu/IJEMS/article/view/5369
_version_ 1797654402683633664
author Csongor Báthory
Péter Pecsmány
Lajos Szalontai
Árpád Bence Palotás
author_facet Csongor Báthory
Péter Pecsmány
Lajos Szalontai
Árpád Bence Palotás
author_sort Csongor Báthory
collection DOAJ
description A stationary and mobile device based on a low-cost dust sensor (Plantower PMS7003) was used to study particulate matter (PM) concentration in Miskolc. The stationary device was placed at the automatic monitoring station of the National Air Quality Measurement Network (OLM) in Martintelep, Miskolc. The mobile device was used to walk 4 streets along a square route with a total length of 800 m. Measurements were made on two days (September 9 and 11) between 7am and 9am, which according to preliminary experience coincided with the morning rush hour. The access route includes the OLM monitoring station, a busy road, two bypasses, a parking lot, and a smaller roadway blocked by traffic. The measured PM1, PM2.5, PM10 concentrations of the mobile device were interpolated on a circuit-by-circuit basis in ArcGIS, and conclusions were drawn for the area. The concentration of stationary and mobile devices was compared.
first_indexed 2024-03-11T16:59:01Z
format Article
id doaj.art-1c3ea487b855463b9d3cc4dc8871783f
institution Directory Open Access Journal
issn 2498-700X
language English
last_indexed 2024-03-11T16:59:01Z
publishDate 2019-12-01
publisher Faculty of Engineering, University of Debrecen
record_format Article
series International Journal of Engineering and Management Sciences
spelling doaj.art-1c3ea487b855463b9d3cc4dc8871783f2023-10-20T12:47:27ZengFaculty of Engineering, University of DebrecenInternational Journal of Engineering and Management Sciences2498-700X2019-12-014410.21791/IJEMS.2019.4.38.Stationary and mobile particulate matter concentration measurement in MiskolcCsongor Báthory0https://orcid.org/0000-0002-2914-8573Péter Pecsmány1Lajos Szalontai 2Árpád Bence Palotás3University of Miskolc, Institute of Energy and Quality AffairsUniversity of Miskolc, Institute of Geography and GeoinformaticsUniversity of Miskolc, Institute of Geography and Geoinformatics, ÉMI Non-Profit LLCUniversity of Miskolc, Institute of Energy and Quality Affairs A stationary and mobile device based on a low-cost dust sensor (Plantower PMS7003) was used to study particulate matter (PM) concentration in Miskolc. The stationary device was placed at the automatic monitoring station of the National Air Quality Measurement Network (OLM) in Martintelep, Miskolc. The mobile device was used to walk 4 streets along a square route with a total length of 800 m. Measurements were made on two days (September 9 and 11) between 7am and 9am, which according to preliminary experience coincided with the morning rush hour. The access route includes the OLM monitoring station, a busy road, two bypasses, a parking lot, and a smaller roadway blocked by traffic. The measured PM1, PM2.5, PM10 concentrations of the mobile device were interpolated on a circuit-by-circuit basis in ArcGIS, and conclusions were drawn for the area. The concentration of stationary and mobile devices was compared. https://ojs.lib.unideb.hu/IJEMS/article/view/5369
spellingShingle Csongor Báthory
Péter Pecsmány
Lajos Szalontai
Árpád Bence Palotás
Stationary and mobile particulate matter concentration measurement in Miskolc
International Journal of Engineering and Management Sciences
title Stationary and mobile particulate matter concentration measurement in Miskolc
title_full Stationary and mobile particulate matter concentration measurement in Miskolc
title_fullStr Stationary and mobile particulate matter concentration measurement in Miskolc
title_full_unstemmed Stationary and mobile particulate matter concentration measurement in Miskolc
title_short Stationary and mobile particulate matter concentration measurement in Miskolc
title_sort stationary and mobile particulate matter concentration measurement in miskolc
url https://ojs.lib.unideb.hu/IJEMS/article/view/5369
work_keys_str_mv AT csongorbathory stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc
AT peterpecsmany stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc
AT lajosszalontai stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc
AT arpadbencepalotas stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc