Stationary and mobile particulate matter concentration measurement in Miskolc
A stationary and mobile device based on a low-cost dust sensor (Plantower PMS7003) was used to study particulate matter (PM) concentration in Miskolc. The stationary device was placed at the automatic monitoring station of the National Air Quality Measurement Network (OLM) in Martintelep, Miskolc....
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Engineering, University of Debrecen
2019-12-01
|
Series: | International Journal of Engineering and Management Sciences |
Online Access: | https://ojs.lib.unideb.hu/IJEMS/article/view/5369 |
_version_ | 1797654402683633664 |
---|---|
author | Csongor Báthory Péter Pecsmány Lajos Szalontai Árpád Bence Palotás |
author_facet | Csongor Báthory Péter Pecsmány Lajos Szalontai Árpád Bence Palotás |
author_sort | Csongor Báthory |
collection | DOAJ |
description |
A stationary and mobile device based on a low-cost dust sensor (Plantower PMS7003) was used to study particulate matter (PM) concentration in Miskolc. The stationary device was placed at the automatic monitoring station of the National Air Quality Measurement Network (OLM) in Martintelep, Miskolc. The mobile device was used to walk 4 streets along a square route with a total length of 800 m. Measurements were made on two days (September 9 and 11) between 7am and 9am, which according to preliminary experience coincided with the morning rush hour. The access route includes the OLM monitoring station, a busy road, two bypasses, a parking lot, and a smaller roadway blocked by traffic. The measured PM1, PM2.5, PM10 concentrations of the mobile device were interpolated on a circuit-by-circuit basis in ArcGIS, and conclusions were drawn for the area. The concentration of stationary and mobile devices was compared.
|
first_indexed | 2024-03-11T16:59:01Z |
format | Article |
id | doaj.art-1c3ea487b855463b9d3cc4dc8871783f |
institution | Directory Open Access Journal |
issn | 2498-700X |
language | English |
last_indexed | 2024-03-11T16:59:01Z |
publishDate | 2019-12-01 |
publisher | Faculty of Engineering, University of Debrecen |
record_format | Article |
series | International Journal of Engineering and Management Sciences |
spelling | doaj.art-1c3ea487b855463b9d3cc4dc8871783f2023-10-20T12:47:27ZengFaculty of Engineering, University of DebrecenInternational Journal of Engineering and Management Sciences2498-700X2019-12-014410.21791/IJEMS.2019.4.38.Stationary and mobile particulate matter concentration measurement in MiskolcCsongor Báthory0https://orcid.org/0000-0002-2914-8573Péter Pecsmány1Lajos Szalontai 2Árpád Bence Palotás3University of Miskolc, Institute of Energy and Quality AffairsUniversity of Miskolc, Institute of Geography and GeoinformaticsUniversity of Miskolc, Institute of Geography and Geoinformatics, ÉMI Non-Profit LLCUniversity of Miskolc, Institute of Energy and Quality Affairs A stationary and mobile device based on a low-cost dust sensor (Plantower PMS7003) was used to study particulate matter (PM) concentration in Miskolc. The stationary device was placed at the automatic monitoring station of the National Air Quality Measurement Network (OLM) in Martintelep, Miskolc. The mobile device was used to walk 4 streets along a square route with a total length of 800 m. Measurements were made on two days (September 9 and 11) between 7am and 9am, which according to preliminary experience coincided with the morning rush hour. The access route includes the OLM monitoring station, a busy road, two bypasses, a parking lot, and a smaller roadway blocked by traffic. The measured PM1, PM2.5, PM10 concentrations of the mobile device were interpolated on a circuit-by-circuit basis in ArcGIS, and conclusions were drawn for the area. The concentration of stationary and mobile devices was compared. https://ojs.lib.unideb.hu/IJEMS/article/view/5369 |
spellingShingle | Csongor Báthory Péter Pecsmány Lajos Szalontai Árpád Bence Palotás Stationary and mobile particulate matter concentration measurement in Miskolc International Journal of Engineering and Management Sciences |
title | Stationary and mobile particulate matter concentration measurement in Miskolc |
title_full | Stationary and mobile particulate matter concentration measurement in Miskolc |
title_fullStr | Stationary and mobile particulate matter concentration measurement in Miskolc |
title_full_unstemmed | Stationary and mobile particulate matter concentration measurement in Miskolc |
title_short | Stationary and mobile particulate matter concentration measurement in Miskolc |
title_sort | stationary and mobile particulate matter concentration measurement in miskolc |
url | https://ojs.lib.unideb.hu/IJEMS/article/view/5369 |
work_keys_str_mv | AT csongorbathory stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc AT peterpecsmany stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc AT lajosszalontai stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc AT arpadbencepalotas stationaryandmobileparticulatematterconcentrationmeasurementinmiskolc |