Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial

Introduction and aim: Transnasal endoscopy (TNE) has proven its diagnostic utility, but it has not been widely accepted given that it is performed without sedation. There are no previous studies on the use of methods to improve its tolerability. Our aim was to evaluate the tolerability of TNE, when...

Full description

Bibliographic Details
Main Authors: J.A. González-González, D.E. Benavides-Salgado, D. Garcia-Compean, B. González-Gómez, J.M. Muñoz-Ayala, R.A. Jiménez-Castillo, H.R. Ibarra-Sifuentes, A. Atilano-Díaz, J. Sordia-Ramírez, M.D. Ramos-Cuevas, H.J. Maldonado-Garza
Format: Article
Language:English
Published: Elsevier 2023-10-01
Series:Revista de Gastroenterología de México (English Edition)
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2255534X2300004X
_version_ 1827395899852062720
author J.A. González-González
D.E. Benavides-Salgado
D. Garcia-Compean
B. González-Gómez
J.M. Muñoz-Ayala
R.A. Jiménez-Castillo
H.R. Ibarra-Sifuentes
A. Atilano-Díaz
J. Sordia-Ramírez
M.D. Ramos-Cuevas
H.J. Maldonado-Garza
author_facet J.A. González-González
D.E. Benavides-Salgado
D. Garcia-Compean
B. González-Gómez
J.M. Muñoz-Ayala
R.A. Jiménez-Castillo
H.R. Ibarra-Sifuentes
A. Atilano-Díaz
J. Sordia-Ramírez
M.D. Ramos-Cuevas
H.J. Maldonado-Garza
author_sort J.A. González-González
collection DOAJ
description Introduction and aim: Transnasal endoscopy (TNE) has proven its diagnostic utility, but it has not been widely accepted given that it is performed without sedation. There are no previous studies on the use of methods to improve its tolerability. Our aim was to evaluate the tolerability of TNE, when simultaneously performed with an audiovisual device as a distractor. Methods: We evaluated 50 patients, 10 of whom did not agree to participate. The performance of the procedure was explained, using an audiovisual device. Before randomization, we applied anxiety and depression scores. Patients were divided into 2 groups: Group I (using an audiovisual device during the procedure) and Group II (without a device). Anxiety and numeric pain rating scales were used, and vital signs were monitored and recorded before, during, and after the endoscopy. An overall procedure satisfaction score was applied at the end of the study and 24 h later. Results: Mean age was 41.6 years and 35 of the patients were women (87.5%). The most frequent indication for TNE was refractory gastroesophageal reflux disease. There were no severe comorbidities, and none of the patients had a significant anxiety or depression score. One patient in Group II did not tolerate TNE due to nasal pain. There was no statistically significant difference between groups, regarding anxiety, pain, vital signs, and satisfaction scale. Conclusion: Our study showed that TNE was well tolerated and had a high acceptance rate in our patients. The use of distracting audiovisual devices did not increase tolerance to the endoscopic procedure. Resumen: Introducción y objetivo: La endoscopía transnasal (ETN) ha probado su utilidad diagnóstica; sin embargo, no se ha aceptado de manera generalizada debido a que se realiza sin sedación y no se han realizado estudios que reporten el uso de métodos que mejoren su tolerabilidad. El objetivo fue evaluar la tolerabilidad de la ETN cuando se realiza de manera simultánea con un dispositivo audiovisual como distractor. Métodos: Se evaluaron 50 pacientes, 10 de ellos rechazaron participar. El procedimiento se explicó utilizando un dispositivo audiovisual. Antes de la aleatorización, se aplicaron escalas de ansiedad y depresión. Los pacientes se dividieron en 2 grupos: Grupo I (utilizando un dispositivo audiovisual durante el procedimiento) y Grupo II (sin dispositivo). Se utilizaron escalas numéricas de ansiedad y dolor. Se monitorearon signos vitales antes, durante y después de la endoscopía. Se aplicó una escala de satisfacción al final del estudio y 24 horas después. Resultados: El promedio de edad fue 41.6 años y 35 (87.5%) pacientes fueron de sexo femenino. La indicación más frecuente para ETN fue enfermedad por reflujo gastroesofágico refractario. No se encontraron comorbilidades significativas y ningún participante contaba con puntuación de ansiedad o depresión significativa. Un paciente del grupo II no toleró la ETN debido a dolor nasal. No se encontró diferencia significativa en niveles de ansiedad y dolor, signos vitales y escala de satisfacción entre grupos. Conclusiones: Nuestro estudio mostró que la ETN es bien tolerada y tiene un porcentaje alto de aceptación en nuestros pacientes. El uso de dispositivos audiovisuales distractores no incrementó la tolerancia al procedimiento endoscópico.
first_indexed 2024-03-08T18:42:37Z
format Article
id doaj.art-1c44ef78b70a427d9801251534d016fa
institution Directory Open Access Journal
issn 2255-534X
language English
last_indexed 2024-03-08T18:42:37Z
publishDate 2023-10-01
publisher Elsevier
record_format Article
series Revista de Gastroenterología de México (English Edition)
spelling doaj.art-1c44ef78b70a427d9801251534d016fa2023-12-29T04:45:27ZengElsevierRevista de Gastroenterología de México (English Edition)2255-534X2023-10-01884347353Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trialJ.A. González-González0D.E. Benavides-Salgado1D. Garcia-Compean2B. González-Gómez3J.M. Muñoz-Ayala4R.A. Jiménez-Castillo5H.R. Ibarra-Sifuentes6A. Atilano-Díaz7J. Sordia-Ramírez8M.D. Ramos-Cuevas9H.J. Maldonado-Garza10Departamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, Mexico; Corresponding author at: Departamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Avda. Madero y Gonzalitos S/N, Monterrey NL, 64460, Mexico. Tel.: +52-81-83-89-11-11.Departamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Medicina Interna, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Psiquiatría, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Ingeniería Biomédica, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoDepartamento de Gastroenterología, Hospital Universitario Dr. José E. González, Universidad Autónoma de Nuevo León, Monterrey, NL, MexicoIntroduction and aim: Transnasal endoscopy (TNE) has proven its diagnostic utility, but it has not been widely accepted given that it is performed without sedation. There are no previous studies on the use of methods to improve its tolerability. Our aim was to evaluate the tolerability of TNE, when simultaneously performed with an audiovisual device as a distractor. Methods: We evaluated 50 patients, 10 of whom did not agree to participate. The performance of the procedure was explained, using an audiovisual device. Before randomization, we applied anxiety and depression scores. Patients were divided into 2 groups: Group I (using an audiovisual device during the procedure) and Group II (without a device). Anxiety and numeric pain rating scales were used, and vital signs were monitored and recorded before, during, and after the endoscopy. An overall procedure satisfaction score was applied at the end of the study and 24 h later. Results: Mean age was 41.6 years and 35 of the patients were women (87.5%). The most frequent indication for TNE was refractory gastroesophageal reflux disease. There were no severe comorbidities, and none of the patients had a significant anxiety or depression score. One patient in Group II did not tolerate TNE due to nasal pain. There was no statistically significant difference between groups, regarding anxiety, pain, vital signs, and satisfaction scale. Conclusion: Our study showed that TNE was well tolerated and had a high acceptance rate in our patients. The use of distracting audiovisual devices did not increase tolerance to the endoscopic procedure. Resumen: Introducción y objetivo: La endoscopía transnasal (ETN) ha probado su utilidad diagnóstica; sin embargo, no se ha aceptado de manera generalizada debido a que se realiza sin sedación y no se han realizado estudios que reporten el uso de métodos que mejoren su tolerabilidad. El objetivo fue evaluar la tolerabilidad de la ETN cuando se realiza de manera simultánea con un dispositivo audiovisual como distractor. Métodos: Se evaluaron 50 pacientes, 10 de ellos rechazaron participar. El procedimiento se explicó utilizando un dispositivo audiovisual. Antes de la aleatorización, se aplicaron escalas de ansiedad y depresión. Los pacientes se dividieron en 2 grupos: Grupo I (utilizando un dispositivo audiovisual durante el procedimiento) y Grupo II (sin dispositivo). Se utilizaron escalas numéricas de ansiedad y dolor. Se monitorearon signos vitales antes, durante y después de la endoscopía. Se aplicó una escala de satisfacción al final del estudio y 24 horas después. Resultados: El promedio de edad fue 41.6 años y 35 (87.5%) pacientes fueron de sexo femenino. La indicación más frecuente para ETN fue enfermedad por reflujo gastroesofágico refractario. No se encontraron comorbilidades significativas y ningún participante contaba con puntuación de ansiedad o depresión significativa. Un paciente del grupo II no toleró la ETN debido a dolor nasal. No se encontró diferencia significativa en niveles de ansiedad y dolor, signos vitales y escala de satisfacción entre grupos. Conclusiones: Nuestro estudio mostró que la ETN es bien tolerada y tiene un porcentaje alto de aceptación en nuestros pacientes. El uso de dispositivos audiovisuales distractores no incrementó la tolerancia al procedimiento endoscópico.http://www.sciencedirect.com/science/article/pii/S2255534X2300004XEndoscopía transnasalTolerabilidadDistractores audiovisuales
spellingShingle J.A. González-González
D.E. Benavides-Salgado
D. Garcia-Compean
B. González-Gómez
J.M. Muñoz-Ayala
R.A. Jiménez-Castillo
H.R. Ibarra-Sifuentes
A. Atilano-Díaz
J. Sordia-Ramírez
M.D. Ramos-Cuevas
H.J. Maldonado-Garza
Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial
Revista de Gastroenterología de México (English Edition)
Endoscopía transnasal
Tolerabilidad
Distractores audiovisuales
title Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial
title_full Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial
title_fullStr Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial
title_full_unstemmed Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial
title_short Use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance. A prospective clinical trial
title_sort use of audiovisual devices in transnasal endoscopy without sedation to improve tolerance a prospective clinical trial
topic Endoscopía transnasal
Tolerabilidad
Distractores audiovisuales
url http://www.sciencedirect.com/science/article/pii/S2255534X2300004X
work_keys_str_mv AT jagonzalezgonzalez useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT debenavidessalgado useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT dgarciacompean useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT bgonzalezgomez useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT jmmunozayala useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT rajimenezcastillo useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT hribarrasifuentes useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT aatilanodiaz useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT jsordiaramirez useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT mdramoscuevas useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial
AT hjmaldonadogarza useofaudiovisualdevicesintransnasalendoscopywithoutsedationtoimprovetoleranceaprospectiveclinicaltrial