Implantable Impedance Plethysmography
We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an i...
Main Authors: | , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2014-08-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/14/8/14858 |
_version_ | 1798005590846341120 |
---|---|
author | Michael Theodor Dominic Ruh Martin Ocker Dominik Spether Katharina Förster Claudia Heilmann Friedhelm Beyersdorf Yiannos Manoli Hans Zappe Andreas Seifert |
author_facet | Michael Theodor Dominic Ruh Martin Ocker Dominik Spether Katharina Förster Claudia Heilmann Friedhelm Beyersdorf Yiannos Manoli Hans Zappe Andreas Seifert |
author_sort | Michael Theodor |
collection | DOAJ |
description | We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term. |
first_indexed | 2024-04-11T12:42:49Z |
format | Article |
id | doaj.art-1c9c5f8d281a43ca8b305037ee69eca6 |
institution | Directory Open Access Journal |
issn | 1424-8220 |
language | English |
last_indexed | 2024-04-11T12:42:49Z |
publishDate | 2014-08-01 |
publisher | MDPI AG |
record_format | Article |
series | Sensors |
spelling | doaj.art-1c9c5f8d281a43ca8b305037ee69eca62022-12-22T04:23:27ZengMDPI AGSensors1424-82202014-08-01148148581487210.3390/s140814858s140814858Implantable Impedance PlethysmographyMichael Theodor0Dominic Ruh1Martin Ocker2Dominik Spether3Katharina Förster4Claudia Heilmann5Friedhelm Beyersdorf6Yiannos Manoli7Hans Zappe8Andreas Seifert9Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyDepartment of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyDepartment of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyDepartment of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyHeart Center Freiburg University, Hugstetter Strasse 55, 79106 Freiburg, GermanyHeart Center Freiburg University, Hugstetter Strasse 55, 79106 Freiburg, GermanyHeart Center Freiburg University, Hugstetter Strasse 55, 79106 Freiburg, GermanyDepartment of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyDepartment of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyDepartment of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 102,79110 Freiburg, GermanyWe demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.http://www.mdpi.com/1424-8220/14/8/14858biomedical implantarterial distensionplethysmographyblood pressure |
spellingShingle | Michael Theodor Dominic Ruh Martin Ocker Dominik Spether Katharina Förster Claudia Heilmann Friedhelm Beyersdorf Yiannos Manoli Hans Zappe Andreas Seifert Implantable Impedance Plethysmography Sensors biomedical implant arterial distension plethysmography blood pressure |
title | Implantable Impedance Plethysmography |
title_full | Implantable Impedance Plethysmography |
title_fullStr | Implantable Impedance Plethysmography |
title_full_unstemmed | Implantable Impedance Plethysmography |
title_short | Implantable Impedance Plethysmography |
title_sort | implantable impedance plethysmography |
topic | biomedical implant arterial distension plethysmography blood pressure |
url | http://www.mdpi.com/1424-8220/14/8/14858 |
work_keys_str_mv | AT michaeltheodor implantableimpedanceplethysmography AT dominicruh implantableimpedanceplethysmography AT martinocker implantableimpedanceplethysmography AT dominikspether implantableimpedanceplethysmography AT katharinaforster implantableimpedanceplethysmography AT claudiaheilmann implantableimpedanceplethysmography AT friedhelmbeyersdorf implantableimpedanceplethysmography AT yiannosmanoli implantableimpedanceplethysmography AT hanszappe implantableimpedanceplethysmography AT andreasseifert implantableimpedanceplethysmography |