Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)

In this article, we examined several longitudinal-sectional sizes of a silencer whose volume was limited by the thickness and aperture ratio of the ventilation door. We report the results of improvement in the sound attenuation properties of these shapes. As an evaluation method for the silencer, we...

Full description

Bibliographic Details
Main Authors: Shuichi SAKAMOTO, Munehiro ISHIDA, Mizuki CHINDA
Format: Article
Language:Japanese
Published: The Japan Society of Mechanical Engineers 2017-05-01
Series:Nihon Kikai Gakkai ronbunshu
Subjects:
Online Access:https://www.jstage.jst.go.jp/article/transjsme/83/850/83_16-00575/_pdf/-char/en
_version_ 1811317735519420416
author Shuichi SAKAMOTO
Munehiro ISHIDA
Mizuki CHINDA
author_facet Shuichi SAKAMOTO
Munehiro ISHIDA
Mizuki CHINDA
author_sort Shuichi SAKAMOTO
collection DOAJ
description In this article, we examined several longitudinal-sectional sizes of a silencer whose volume was limited by the thickness and aperture ratio of the ventilation door. We report the results of improvement in the sound attenuation properties of these shapes. As an evaluation method for the silencer, we measured transmission losses using an impedance measurement tube and calculated them on the basis of a theoretical analysis. The following results were obtained from the evaluation of the silencer using the measurement and calculation results and from the verification of the improved shape of a silencer and silencer array. For a side branch tube silencer with a 1/3 aperture ratio, assuming that it is installed into the ventilation door, we observed a side branch tube with an linear expanded longitudinal-sectional shape by improving the shape using the theoretical analysis of transmission losses. In addition, as a result of the experiment with a sample on the basis of the theoretical analysis, both the experimental and the theoretical analysis were in good agreement. Furthermore, the expanded shape of the longitudinal-section of the side branch tube decreased the frequency of the sound attenuation peak. It was found that a silencer with a combination of four of these silencers can be arrayed side-by-side in a ventilation door; this results in a flat transmission loss of more than 5 dB over a broad band.
first_indexed 2024-04-13T12:13:32Z
format Article
id doaj.art-1cb521ec571d473186c408c1fcf47536
institution Directory Open Access Journal
issn 2187-9761
language Japanese
last_indexed 2024-04-13T12:13:32Z
publishDate 2017-05-01
publisher The Japan Society of Mechanical Engineers
record_format Article
series Nihon Kikai Gakkai ronbunshu
spelling doaj.art-1cb521ec571d473186c408c1fcf475362022-12-22T02:47:26ZjpnThe Japan Society of Mechanical EngineersNihon Kikai Gakkai ronbunshu2187-97612017-05-018385016-0057516-0057510.1299/transjsme.16-00575transjsmeStudy of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)Shuichi SAKAMOTO0Munehiro ISHIDA1Mizuki CHINDA2Faculty of Engineering, Niigata UniversityGraduate School of Science and Technology, Niigata UniversityGraduate School of Science and Technology, Niigata UniversityIn this article, we examined several longitudinal-sectional sizes of a silencer whose volume was limited by the thickness and aperture ratio of the ventilation door. We report the results of improvement in the sound attenuation properties of these shapes. As an evaluation method for the silencer, we measured transmission losses using an impedance measurement tube and calculated them on the basis of a theoretical analysis. The following results were obtained from the evaluation of the silencer using the measurement and calculation results and from the verification of the improved shape of a silencer and silencer array. For a side branch tube silencer with a 1/3 aperture ratio, assuming that it is installed into the ventilation door, we observed a side branch tube with an linear expanded longitudinal-sectional shape by improving the shape using the theoretical analysis of transmission losses. In addition, as a result of the experiment with a sample on the basis of the theoretical analysis, both the experimental and the theoretical analysis were in good agreement. Furthermore, the expanded shape of the longitudinal-section of the side branch tube decreased the frequency of the sound attenuation peak. It was found that a silencer with a combination of four of these silencers can be arrayed side-by-side in a ventilation door; this results in a flat transmission loss of more than 5 dB over a broad band.https://www.jstage.jst.go.jp/article/transjsme/83/850/83_16-00575/_pdf/-char/ennoise controlsound transmission lossside branch silencerventilation doorsilencer designs
spellingShingle Shuichi SAKAMOTO
Munehiro ISHIDA
Mizuki CHINDA
Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)
Nihon Kikai Gakkai ronbunshu
noise control
sound transmission loss
side branch silencer
ventilation door
silencer designs
title Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)
title_full Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)
title_fullStr Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)
title_full_unstemmed Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)
title_short Study of arrayed side branch silencer for ventilation door (Improvement of attenuation characteristic using of the linear expanded shape side branch tube)
title_sort study of arrayed side branch silencer for ventilation door improvement of attenuation characteristic using of the linear expanded shape side branch tube
topic noise control
sound transmission loss
side branch silencer
ventilation door
silencer designs
url https://www.jstage.jst.go.jp/article/transjsme/83/850/83_16-00575/_pdf/-char/en
work_keys_str_mv AT shuichisakamoto studyofarrayedsidebranchsilencerforventilationdoorimprovementofattenuationcharacteristicusingofthelinearexpandedshapesidebranchtube
AT munehiroishida studyofarrayedsidebranchsilencerforventilationdoorimprovementofattenuationcharacteristicusingofthelinearexpandedshapesidebranchtube
AT mizukichinda studyofarrayedsidebranchsilencerforventilationdoorimprovementofattenuationcharacteristicusingofthelinearexpandedshapesidebranchtube