Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators

Heat transfer has been improved by creating turbulence in the fluid flow of heat exchangers through introducing various techniques. The present study investigated the heat transfer characteristics of steam generator with circular-ring tabulators with an inclination angle of 45° and a blocked ratio (...

Full description

Bibliographic Details
Main Authors: Bancha Lamlerd, Bopit Bubphachot, Teerapat Chompookham
Format: Article
Language:English
Published: Elsevier 2023-01-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X22007869
_version_ 1797956221677862912
author Bancha Lamlerd
Bopit Bubphachot
Teerapat Chompookham
author_facet Bancha Lamlerd
Bopit Bubphachot
Teerapat Chompookham
author_sort Bancha Lamlerd
collection DOAJ
description Heat transfer has been improved by creating turbulence in the fluid flow of heat exchangers through introducing various techniques. The present study investigated the heat transfer characteristics of steam generator with circular-ring tabulators with an inclination angle of 45° and a blocked ratio (BR) of 0.20 mm. The length ratios (LR) of 25%, 50%, 75% and 100%, pitch ratios (PR) of 1.0, 2.0, 3.0 and 4.0 and water flow rates of 12, 24 and 36 l/h were studied. The heat source used waste lubricating oil as fuel to produce steam. The results showed that the heat exchanger with circular-ring inserts provided a higher steam rate than that of a smooth tube by 6.88–10.35%, vapor quality (x) by 0.21–0.92, heat transfer by 1.27–1.55 times and the thermal efficiency by 0.46–0.68 depending on the PR, LR and FR. The optimum insert ratio was LR = 50% while 75% and 100% were not significantly different. The circular-ring inserts changed the flow behavior to turbulent flow. This increased the surface area, causing boundary layer interruptions leading to more heat exchange on the tube surface.
first_indexed 2024-04-10T23:45:32Z
format Article
id doaj.art-1d1c68732ce2413fa4400c437a1da744
institution Directory Open Access Journal
issn 2214-157X
language English
last_indexed 2024-04-10T23:45:32Z
publishDate 2023-01-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj.art-1d1c68732ce2413fa4400c437a1da7442023-01-11T04:28:55ZengElsevierCase Studies in Thermal Engineering2214-157X2023-01-0141102549Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulatorsBancha Lamlerd0Bopit Bubphachot1Teerapat Chompookham2Heat Pipe and Thermal Tools Design Research Unit (HTDR), Department of Mechanical Engineering, Faculty of Engineering, Mahasarakham University, Khamriang, Kantarawichai, Maha Sarakham, 44150, ThailandCorresponding author.; Heat Pipe and Thermal Tools Design Research Unit (HTDR), Department of Mechanical Engineering, Faculty of Engineering, Mahasarakham University, Khamriang, Kantarawichai, Maha Sarakham, 44150, ThailandHeat Pipe and Thermal Tools Design Research Unit (HTDR), Department of Mechanical Engineering, Faculty of Engineering, Mahasarakham University, Khamriang, Kantarawichai, Maha Sarakham, 44150, ThailandHeat transfer has been improved by creating turbulence in the fluid flow of heat exchangers through introducing various techniques. The present study investigated the heat transfer characteristics of steam generator with circular-ring tabulators with an inclination angle of 45° and a blocked ratio (BR) of 0.20 mm. The length ratios (LR) of 25%, 50%, 75% and 100%, pitch ratios (PR) of 1.0, 2.0, 3.0 and 4.0 and water flow rates of 12, 24 and 36 l/h were studied. The heat source used waste lubricating oil as fuel to produce steam. The results showed that the heat exchanger with circular-ring inserts provided a higher steam rate than that of a smooth tube by 6.88–10.35%, vapor quality (x) by 0.21–0.92, heat transfer by 1.27–1.55 times and the thermal efficiency by 0.46–0.68 depending on the PR, LR and FR. The optimum insert ratio was LR = 50% while 75% and 100% were not significantly different. The circular-ring inserts changed the flow behavior to turbulent flow. This increased the surface area, causing boundary layer interruptions leading to more heat exchange on the tube surface.http://www.sciencedirect.com/science/article/pii/S2214157X22007869Heat exchangerSteam rateVapor qualityCircular-ring turbulatorAngled baffle
spellingShingle Bancha Lamlerd
Bopit Bubphachot
Teerapat Chompookham
Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators
Case Studies in Thermal Engineering
Heat exchanger
Steam rate
Vapor quality
Circular-ring turbulator
Angled baffle
title Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators
title_full Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators
title_fullStr Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators
title_full_unstemmed Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators
title_short Experimental investigation of heat transfer characteristics of steam generator with circular-ring turbulators
title_sort experimental investigation of heat transfer characteristics of steam generator with circular ring turbulators
topic Heat exchanger
Steam rate
Vapor quality
Circular-ring turbulator
Angled baffle
url http://www.sciencedirect.com/science/article/pii/S2214157X22007869
work_keys_str_mv AT banchalamlerd experimentalinvestigationofheattransfercharacteristicsofsteamgeneratorwithcircularringturbulators
AT bopitbubphachot experimentalinvestigationofheattransfercharacteristicsofsteamgeneratorwithcircularringturbulators
AT teerapatchompookham experimentalinvestigationofheattransfercharacteristicsofsteamgeneratorwithcircularringturbulators