Bistable, Pneumatically Actuated Microgripper Fabricated Using Two‐Photon Polymerization and Oxygen Plasma Etching

Fabrication of actuatable micromechanisms onto the tip of submillimeter medical instruments permits microsurgery, cellular‐level intervention, targeted drug delivery, or placement of microimplants. In these systems, a common lack of integrated microsensors or optical feedback prohibits stabilizing c...

תיאור מלא

מידע ביבליוגרפי
Main Authors: Maura Power, Antoine Barbot, Florent Seichepine, Guang-Zhong Yang
פורמט: Article
שפה:English
יצא לאור: Wiley 2023-04-01
סדרה:Advanced Intelligent Systems
נושאים:
גישה מקוונת:https://doi.org/10.1002/aisy.202200121