Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study

To maintain proper indoor air quality and increase energy efficiency, a demand-control ventilation (DCV) system has become a popular solution. This paper reports the findings of a field study conducted on the performance of the DCV systems in eight public buildings in southern Finland. We conducted...

Full description

Bibliographic Details
Main Authors: Weixin Zhao, Simo Kilpeläinen, Wertti Bask, Sami Lestinen, Risto Kosonen
Format: Article
Language:English
Published: MDPI AG 2022-03-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/12/3/378
_version_ 1797472497865588736
author Weixin Zhao
Simo Kilpeläinen
Wertti Bask
Sami Lestinen
Risto Kosonen
author_facet Weixin Zhao
Simo Kilpeläinen
Wertti Bask
Sami Lestinen
Risto Kosonen
author_sort Weixin Zhao
collection DOAJ
description To maintain proper indoor air quality and increase energy efficiency, a demand-control ventilation (DCV) system has become a popular solution. This paper reports the findings of a field study conducted on the performance of the DCV systems in eight public buildings in southern Finland. We conducted the measurements in two stages. In the first stage, we made a site visit and measured the airflow rates in the design operation conditions of the chosen space. For the second stage, we left temperature/humidity data loggers to monitor the thermal conditions during the normal operation mode of the space. The results indicate that, out of the eight studied spaces, only one DCV system was performing according to design specifications. While the systems were operating in a suboptimal way, the flaws in functionality were mostly minor, and none of the sites had perceived indoor-air-quality- and/or thermal-condition-related problems during the time of measurement. Nonetheless, this result shows that the potential benefits of DCV were partially lost due to malfunctioning systems. Additionally, by only monitoring room air temperature (or IAQ) without airflow rate measurements in different operation modes, it is not possible to conclude whether the DCV system works properly or not.
first_indexed 2024-03-09T20:02:35Z
format Article
id doaj.art-1deef876225747dd8ca44e1df3d6c815
institution Directory Open Access Journal
issn 2075-5309
language English
last_indexed 2024-03-09T20:02:35Z
publishDate 2022-03-01
publisher MDPI AG
record_format Article
series Buildings
spelling doaj.art-1deef876225747dd8ca44e1df3d6c8152023-11-24T00:39:41ZengMDPI AGBuildings2075-53092022-03-0112337810.3390/buildings12030378Operational Challenges of Modern Demand-Control Ventilation Systems: A Field StudyWeixin Zhao0Simo Kilpeläinen1Wertti Bask2Sami Lestinen3Risto Kosonen4Department of Mechanical Engineering, Aalto University, 02150 Espoo, FinlandDepartment of Mechanical Engineering, Aalto University, 02150 Espoo, FinlandDepartment of Mechanical Engineering, Aalto University, 02150 Espoo, FinlandDepartment of Mechanical Engineering, Aalto University, 02150 Espoo, FinlandDepartment of Mechanical Engineering, Aalto University, 02150 Espoo, FinlandTo maintain proper indoor air quality and increase energy efficiency, a demand-control ventilation (DCV) system has become a popular solution. This paper reports the findings of a field study conducted on the performance of the DCV systems in eight public buildings in southern Finland. We conducted the measurements in two stages. In the first stage, we made a site visit and measured the airflow rates in the design operation conditions of the chosen space. For the second stage, we left temperature/humidity data loggers to monitor the thermal conditions during the normal operation mode of the space. The results indicate that, out of the eight studied spaces, only one DCV system was performing according to design specifications. While the systems were operating in a suboptimal way, the flaws in functionality were mostly minor, and none of the sites had perceived indoor-air-quality- and/or thermal-condition-related problems during the time of measurement. Nonetheless, this result shows that the potential benefits of DCV were partially lost due to malfunctioning systems. Additionally, by only monitoring room air temperature (or IAQ) without airflow rate measurements in different operation modes, it is not possible to conclude whether the DCV system works properly or not.https://www.mdpi.com/2075-5309/12/3/378demand-control ventilationperformance of ventilation systempublic buildingsfield study
spellingShingle Weixin Zhao
Simo Kilpeläinen
Wertti Bask
Sami Lestinen
Risto Kosonen
Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study
Buildings
demand-control ventilation
performance of ventilation system
public buildings
field study
title Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study
title_full Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study
title_fullStr Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study
title_full_unstemmed Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study
title_short Operational Challenges of Modern Demand-Control Ventilation Systems: A Field Study
title_sort operational challenges of modern demand control ventilation systems a field study
topic demand-control ventilation
performance of ventilation system
public buildings
field study
url https://www.mdpi.com/2075-5309/12/3/378
work_keys_str_mv AT weixinzhao operationalchallengesofmoderndemandcontrolventilationsystemsafieldstudy
AT simokilpelainen operationalchallengesofmoderndemandcontrolventilationsystemsafieldstudy
AT werttibask operationalchallengesofmoderndemandcontrolventilationsystemsafieldstudy
AT samilestinen operationalchallengesofmoderndemandcontrolventilationsystemsafieldstudy
AT ristokosonen operationalchallengesofmoderndemandcontrolventilationsystemsafieldstudy