Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India
Background and objectives: Laboratory medicine is equally challenged by economic and new technological pressures. Clinical laboratories have undergone major change due to advancement of technology, which has improved the decision making of clinicians but introduced the risk of errors. This study aim...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Golestan University Of Medical Sciences
2021-12-01
|
Series: | Journal of Clinical and Basic Research |
Subjects: | |
Online Access: | http://jcbr.goums.ac.ir/article-1-334-en.html |
_version_ | 1797974458824130560 |
---|---|
author | KAPILA GAIKWAD SOHAN SELKAR |
author_facet | KAPILA GAIKWAD SOHAN SELKAR |
author_sort | KAPILA GAIKWAD |
collection | DOAJ |
description | Background and objectives: Laboratory medicine is equally challenged by economic and new technological pressures. Clinical laboratories have undergone major change due to advancement of technology, which has improved the decision making of clinicians but introduced the risk of errors. This study aimed to evaluate the errors that occurred in the pre-analytical phase of laboratory testing.
Methods: This was a prospective observational study that was done in the Clinical Biochemistry Laboratory of a tertiary care center from June 2016 to May 2017. The path of the sample was analyzed from sample collection to transport. Frequency of deficiencies in the request forms and different types of pre-analytical errors were recorded.
Results: During the study period, the frequency of pre-analytical errors was about 3.1%. Sample hemolysis was the predominant error in sample collected from both indoor and outdoor patients.
Conclusion: Proper management of pre-analytical errors requires continuous evaluation of source of errors, taking corrective measures, and significant interdepartmental cooperation. |
first_indexed | 2024-04-11T04:20:16Z |
format | Article |
id | doaj.art-1e326725ad2e4a05a34238d47e783f19 |
institution | Directory Open Access Journal |
issn | 2538-3736 |
language | English |
last_indexed | 2024-04-11T04:20:16Z |
publishDate | 2021-12-01 |
publisher | Golestan University Of Medical Sciences |
record_format | Article |
series | Journal of Clinical and Basic Research |
spelling | doaj.art-1e326725ad2e4a05a34238d47e783f192022-12-30T17:26:03ZengGolestan University Of Medical SciencesJournal of Clinical and Basic Research2538-37362021-12-015418Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in IndiaKAPILA GAIKWAD0SOHAN SELKAR1 Department of Biochemistry, Shyam Shah Medical College, REWA, Madhya Pradesh, India Department of Musculoskeletal Sciences, Datta Meghe College of Physiotherapy, Wanadongri, Nagpur, Maharashtra, India Background and objectives: Laboratory medicine is equally challenged by economic and new technological pressures. Clinical laboratories have undergone major change due to advancement of technology, which has improved the decision making of clinicians but introduced the risk of errors. This study aimed to evaluate the errors that occurred in the pre-analytical phase of laboratory testing. Methods: This was a prospective observational study that was done in the Clinical Biochemistry Laboratory of a tertiary care center from June 2016 to May 2017. The path of the sample was analyzed from sample collection to transport. Frequency of deficiencies in the request forms and different types of pre-analytical errors were recorded. Results: During the study period, the frequency of pre-analytical errors was about 3.1%. Sample hemolysis was the predominant error in sample collected from both indoor and outdoor patients. Conclusion: Proper management of pre-analytical errors requires continuous evaluation of source of errors, taking corrective measures, and significant interdepartmental cooperation.http://jcbr.goums.ac.ir/article-1-334-en.htmlpreanalytical errorslaboratory errorshemolysed samplelipemic samplelaboratory medicine |
spellingShingle | KAPILA GAIKWAD SOHAN SELKAR Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India Journal of Clinical and Basic Research preanalytical errors laboratory errors hemolysed sample lipemic sample laboratory medicine |
title | Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India |
title_full | Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India |
title_fullStr | Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India |
title_full_unstemmed | Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India |
title_short | Evaluation of Pre-Analytical Errors in Clinical Biochemistry Laboratory of a Tertiary Care Center in India |
title_sort | evaluation of pre analytical errors in clinical biochemistry laboratory of a tertiary care center in india |
topic | preanalytical errors laboratory errors hemolysed sample lipemic sample laboratory medicine |
url | http://jcbr.goums.ac.ir/article-1-334-en.html |
work_keys_str_mv | AT kapilagaikwad evaluationofpreanalyticalerrorsinclinicalbiochemistrylaboratoryofatertiarycarecenterinindia AT sohanselkar evaluationofpreanalyticalerrorsinclinicalbiochemistrylaboratoryofatertiarycarecenterinindia |