Improvement of Radiant Heat Efficiency of the Radiant Tube Used for Continuous Annealing Line by Application of Additive Manufacturing Technology
This study presents the application of additive manufacturing (AM) technology to a W-type INCONEL radiant tube (RT) used to improve its radiant heat efficiency. Appropriate dimensions of honeycomb structure were determined from finite element (FE) analysis and the resulting increase in radiant heat...