Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System

The purpose of this work is to determine the values of electrical parameters of synchronous and induction machines to validate electrical interactions between an induction generator and a synchronous generator. The generators are connected in two ways: (i) isolated from the common bus and (ii) paral...

Full description

Bibliographic Details
Main Authors: Alan H. F. Silva, Alana S. Magalhaes, Junio S. Bulhoes, Gabriel A. Wainer, Gevanne P. Furriel, Wesley P. Calixto
Format: Article
Language:English
Published: MDPI AG 2021-06-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/13/3875
_version_ 1797528511361056768
author Alan H. F. Silva
Alana S. Magalhaes
Junio S. Bulhoes
Gabriel A. Wainer
Gevanne P. Furriel
Wesley P. Calixto
author_facet Alan H. F. Silva
Alana S. Magalhaes
Junio S. Bulhoes
Gabriel A. Wainer
Gevanne P. Furriel
Wesley P. Calixto
author_sort Alan H. F. Silva
collection DOAJ
description The purpose of this work is to determine the values of electrical parameters of synchronous and induction machines to validate electrical interactions between an induction generator and a synchronous generator. The generators are connected in two ways: (i) isolated from the common bus and (ii) parallel to the common bus in steady state, subject to nonlinear load. They are old and refurbished machines; thus, the parametric regression methodology is used to determine the electrical parameter values. After the computational model validation, analyses are performed by various system configurations to confirm the repowering and to analyze the system harmonic current flow. The results obtained comparing the computer simulation and experimental tests prove that the validated model represents the real system. With an experimentally validated computational model, it is possible to verify the occurrence of system repowering and the increased value of harmonic distortions in the induction generator terminals, acting as a preferential path for harmonic currents.
first_indexed 2024-03-10T10:00:22Z
format Article
id doaj.art-1fa169f1c53c442cacd77e8fd28cb8f8
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T10:00:22Z
publishDate 2021-06-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-1fa169f1c53c442cacd77e8fd28cb8f82023-11-22T01:58:58ZengMDPI AGEnergies1996-10732021-06-011413387510.3390/en14133875Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering SystemAlan H. F. Silva0Alana S. Magalhaes1Junio S. Bulhoes2Gabriel A. Wainer3Gevanne P. Furriel4Wesley P. Calixto5Studies and Research in Science and Technology Group (GCITE), Federal Institute of Goias (IFG), Goiania 74055-110, BrazilStudies and Research in Science and Technology Group (GCITE), Federal Institute of Goias (IFG), Goiania 74055-110, BrazilStudies and Research in Science and Technology Group (GCITE), Federal Institute of Goias (IFG), Goiania 74055-110, BrazilVisualization, Simulation and Modeling (VSIM), Carleton University, Ottawa, ON K1S 5B6, CanadaElectrical, Mechanical & Computer Engineering School (EMC), Federal University of Goias (UFG), Goiania 74605-010, BrazilStudies and Research in Science and Technology Group (GCITE), Federal Institute of Goias (IFG), Goiania 74055-110, BrazilThe purpose of this work is to determine the values of electrical parameters of synchronous and induction machines to validate electrical interactions between an induction generator and a synchronous generator. The generators are connected in two ways: (i) isolated from the common bus and (ii) parallel to the common bus in steady state, subject to nonlinear load. They are old and refurbished machines; thus, the parametric regression methodology is used to determine the electrical parameter values. After the computational model validation, analyses are performed by various system configurations to confirm the repowering and to analyze the system harmonic current flow. The results obtained comparing the computer simulation and experimental tests prove that the validated model represents the real system. With an experimentally validated computational model, it is possible to verify the occurrence of system repowering and the increased value of harmonic distortions in the induction generator terminals, acting as a preferential path for harmonic currents.https://www.mdpi.com/1996-1073/14/13/3875parametric regressioninduction generatorsynchronous generatorharmonic distortions
spellingShingle Alan H. F. Silva
Alana S. Magalhaes
Junio S. Bulhoes
Gabriel A. Wainer
Gevanne P. Furriel
Wesley P. Calixto
Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System
Energies
parametric regression
induction generator
synchronous generator
harmonic distortions
title Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System
title_full Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System
title_fullStr Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System
title_full_unstemmed Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System
title_short Parametric Regression Applied for Determination of Electrical Parameters of Synchronous and Induction Generators Operating in Parallel on the Electrical Energy Repowering System
title_sort parametric regression applied for determination of electrical parameters of synchronous and induction generators operating in parallel on the electrical energy repowering system
topic parametric regression
induction generator
synchronous generator
harmonic distortions
url https://www.mdpi.com/1996-1073/14/13/3875
work_keys_str_mv AT alanhfsilva parametricregressionappliedfordeterminationofelectricalparametersofsynchronousandinductiongeneratorsoperatinginparallelontheelectricalenergyrepoweringsystem
AT alanasmagalhaes parametricregressionappliedfordeterminationofelectricalparametersofsynchronousandinductiongeneratorsoperatinginparallelontheelectricalenergyrepoweringsystem
AT juniosbulhoes parametricregressionappliedfordeterminationofelectricalparametersofsynchronousandinductiongeneratorsoperatinginparallelontheelectricalenergyrepoweringsystem
AT gabrielawainer parametricregressionappliedfordeterminationofelectricalparametersofsynchronousandinductiongeneratorsoperatinginparallelontheelectricalenergyrepoweringsystem
AT gevannepfurriel parametricregressionappliedfordeterminationofelectricalparametersofsynchronousandinductiongeneratorsoperatinginparallelontheelectricalenergyrepoweringsystem
AT wesleypcalixto parametricregressionappliedfordeterminationofelectricalparametersofsynchronousandinductiongeneratorsoperatinginparallelontheelectricalenergyrepoweringsystem