Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations

A procedure based on energy-dispersive X-ray spectroscopy in a scanning electron microscope (SEM-EDXS) is proposed to measure ultra-thin oxide layer thicknesses to atomic scale precision in top-down instead of cross-sectional geometry. The approach is based on modelling the variation of the electron...

Full description

Bibliographic Details
Main Author: Thomas Walther
Format: Article
Language:English
Published: MDPI AG 2021-08-01
Series:Nanomaterials
Subjects:
Online Access:https://www.mdpi.com/2079-4991/11/8/2117
_version_ 1827684417852669952
author Thomas Walther
author_facet Thomas Walther
author_sort Thomas Walther
collection DOAJ
description A procedure based on energy-dispersive X-ray spectroscopy in a scanning electron microscope (SEM-EDXS) is proposed to measure ultra-thin oxide layer thicknesses to atomic scale precision in top-down instead of cross-sectional geometry. The approach is based on modelling the variation of the electron beam penetration depth and hence the depth of X-ray generation in the sample as a function of the acceleration voltage. This has been tested for the simple case of silica on silicon (SiO<sub>2</sub>/Si) which can serve as a model system to study gate oxides in metal-on-semiconductor field-effect transistors (MOS-FETs). Two possible implementations exist both of which rely on pairs of measurements to be made: in method A, the wafer piece of interest and a reference sample (here: ultra-clean fused quartz glass for calibration of the effective k-factors of X-ray lines from elements O and Si) are analysed at the same acceleration voltage. In method B, two measurements of the apparent O/Si ratio of the same wafer sample need to be made at different acceleration voltages and from their comparison to simulations the SiO<sub>2</sub> layer thickness of the sample can be inferred. The precision attainable is ultimately shown to be limited by surface contamination during the experiments, as very thin carbonaceous surface layers can alter the results at very low acceleration voltages, while the sensitivity to ultra-thin surface oxides is much reduced at higher acceleration voltages. The optimal operation voltage is estimated to lie in the range of 3–15 kV. Method A has been experimentally verified to work well for test structures of thin oxides on Si-Ge/Si.
first_indexed 2024-03-10T08:30:56Z
format Article
id doaj.art-1fe1f87829844ddbbd4b96db89d3621b
institution Directory Open Access Journal
issn 2079-4991
language English
last_indexed 2024-03-10T08:30:56Z
publishDate 2021-08-01
publisher MDPI AG
record_format Article
series Nanomaterials
spelling doaj.art-1fe1f87829844ddbbd4b96db89d3621b2023-11-22T09:00:45ZengMDPI AGNanomaterials2079-49912021-08-01118211710.3390/nano11082117Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo SimulationsThomas Walther0Department of Electronic & Electrical Engineering, University of Sheffield, Mappin Street, Sheffield S1 3JD, UKA procedure based on energy-dispersive X-ray spectroscopy in a scanning electron microscope (SEM-EDXS) is proposed to measure ultra-thin oxide layer thicknesses to atomic scale precision in top-down instead of cross-sectional geometry. The approach is based on modelling the variation of the electron beam penetration depth and hence the depth of X-ray generation in the sample as a function of the acceleration voltage. This has been tested for the simple case of silica on silicon (SiO<sub>2</sub>/Si) which can serve as a model system to study gate oxides in metal-on-semiconductor field-effect transistors (MOS-FETs). Two possible implementations exist both of which rely on pairs of measurements to be made: in method A, the wafer piece of interest and a reference sample (here: ultra-clean fused quartz glass for calibration of the effective k-factors of X-ray lines from elements O and Si) are analysed at the same acceleration voltage. In method B, two measurements of the apparent O/Si ratio of the same wafer sample need to be made at different acceleration voltages and from their comparison to simulations the SiO<sub>2</sub> layer thickness of the sample can be inferred. The precision attainable is ultimately shown to be limited by surface contamination during the experiments, as very thin carbonaceous surface layers can alter the results at very low acceleration voltages, while the sensitivity to ultra-thin surface oxides is much reduced at higher acceleration voltages. The optimal operation voltage is estimated to lie in the range of 3–15 kV. Method A has been experimentally verified to work well for test structures of thin oxides on Si-Ge/Si.https://www.mdpi.com/2079-4991/11/8/2117energy-dispersive X-ray spectroscopy (EDXS)scanning electron microscopy (SEM)penetration depthoxide thicknessgate oxides
spellingShingle Thomas Walther
Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations
Nanomaterials
energy-dispersive X-ray spectroscopy (EDXS)
scanning electron microscopy (SEM)
penetration depth
oxide thickness
gate oxides
title Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations
title_full Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations
title_fullStr Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations
title_full_unstemmed Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations
title_short Measurement of Nanometre-Scale Gate Oxide Thicknesses by Energy-Dispersive X-ray Spectroscopy in a Scanning Electron Microscope Combined with Monte Carlo Simulations
title_sort measurement of nanometre scale gate oxide thicknesses by energy dispersive x ray spectroscopy in a scanning electron microscope combined with monte carlo simulations
topic energy-dispersive X-ray spectroscopy (EDXS)
scanning electron microscopy (SEM)
penetration depth
oxide thickness
gate oxides
url https://www.mdpi.com/2079-4991/11/8/2117
work_keys_str_mv AT thomaswalther measurementofnanometrescalegateoxidethicknessesbyenergydispersivexrayspectroscopyinascanningelectronmicroscopecombinedwithmontecarlosimulations