An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting
An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF) power source. The received RF power level can be sensed and wirelessly transmitted along with bl...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
International Institute of Informatics and Cybernetics
2015-08-01
|
Series: | Journal of Systemics, Cybernetics and Informatics |
Subjects: | |
Online Access: | http://www.iiisci.org/Journal/CV$/sci/pdfs/BA922ZL15.pdf
|
_version_ | 1818512582797950976 |
---|---|
author | Yu-Chun Liu Jiann-Shiun Yuan Ekavut Kritchanchai |
author_facet | Yu-Chun Liu Jiann-Shiun Yuan Ekavut Kritchanchai |
author_sort | Yu-Chun Liu |
collection | DOAJ |
description | An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF) power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The integrated electronic system, consisting of a capacitance-to-voltage converter, an adaptive RF powering system, an RF transmitter and digital control circuitry, is simulated using a TSMC 0.18 μm CMOS technology. The implanted RF transmitter circuit is combined with a low power voltage-controlled oscillator resonating at 5.8 GHz and a power amplifier. For the design, the simulation model is setup using ADS and HFSS software. The dimension of the antenna is 1 × 0.6 × 4.8 mm<sup>3</sup> with a 1 × 0.6 mm<sup>2</sup> on-chip circuit which is small enough to place in human carotid artery. |
first_indexed | 2024-12-10T23:48:50Z |
format | Article |
id | doaj.art-2037d6099aba46d98d54fa68cbdee526 |
institution | Directory Open Access Journal |
issn | 1690-4524 |
language | English |
last_indexed | 2024-12-10T23:48:50Z |
publishDate | 2015-08-01 |
publisher | International Institute of Informatics and Cybernetics |
record_format | Article |
series | Journal of Systemics, Cybernetics and Informatics |
spelling | doaj.art-2037d6099aba46d98d54fa68cbdee5262022-12-22T01:28:50ZengInternational Institute of Informatics and CyberneticsJournal of Systemics, Cybernetics and Informatics1690-45242015-08-0113416An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy HarvestingYu-Chun Liu0Jiann-Shiun Yuan1Ekavut Kritchanchai2 An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF) power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The integrated electronic system, consisting of a capacitance-to-voltage converter, an adaptive RF powering system, an RF transmitter and digital control circuitry, is simulated using a TSMC 0.18 μm CMOS technology. The implanted RF transmitter circuit is combined with a low power voltage-controlled oscillator resonating at 5.8 GHz and a power amplifier. For the design, the simulation model is setup using ADS and HFSS software. The dimension of the antenna is 1 × 0.6 × 4.8 mm<sup>3</sup> with a 1 × 0.6 mm<sup>2</sup> on-chip circuit which is small enough to place in human carotid artery.http://www.iiisci.org/Journal/CV$/sci/pdfs/BA922ZL15.pdf energy harvestinglink budget blockRF rectifier |
spellingShingle | Yu-Chun Liu Jiann-Shiun Yuan Ekavut Kritchanchai An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting Journal of Systemics, Cybernetics and Informatics energy harvesting link budget block RF rectifier |
title | An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting |
title_full | An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting |
title_fullStr | An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting |
title_full_unstemmed | An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting |
title_short | An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting |
title_sort | implantable cardiovascular pressure monitoring system with on chip antenna and rf energy harvesting |
topic | energy harvesting link budget block RF rectifier |
url | http://www.iiisci.org/Journal/CV$/sci/pdfs/BA922ZL15.pdf
|
work_keys_str_mv | AT yuchunliu animplantablecardiovascularpressuremonitoringsystemwithonchipantennaandrfenergyharvesting AT jiannshiunyuan animplantablecardiovascularpressuremonitoringsystemwithonchipantennaandrfenergyharvesting AT ekavutkritchanchai animplantablecardiovascularpressuremonitoringsystemwithonchipantennaandrfenergyharvesting AT yuchunliu implantablecardiovascularpressuremonitoringsystemwithonchipantennaandrfenergyharvesting AT jiannshiunyuan implantablecardiovascularpressuremonitoringsystemwithonchipantennaandrfenergyharvesting AT ekavutkritchanchai implantablecardiovascularpressuremonitoringsystemwithonchipantennaandrfenergyharvesting |