Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos

This study evaluated some mechanical parameters of Z250 composite resin using different light-curing methods. Ten specimens were prepared for each mechanical test group with different dimensions according to the test. Light-curing was performed by: a). continuous light (800mW/cm²-40s); b). exponenti...

Full description

Bibliographic Details
Main Authors: Andresa Carla Obici, Mário Alexandre Coelho Sinhoreti, Lourenço Correr-Sobrinho, Mário Fernando de Góes, Simonides Consani
Format: Article
Language:English
Published: University of São Paulo 2005-12-01
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572005000400015
_version_ 1831776032497074176
author Andresa Carla Obici
Mário Alexandre Coelho Sinhoreti
Lourenço Correr-Sobrinho
Mário Fernando de Góes
Simonides Consani
author_facet Andresa Carla Obici
Mário Alexandre Coelho Sinhoreti
Lourenço Correr-Sobrinho
Mário Fernando de Góes
Simonides Consani
author_sort Andresa Carla Obici
collection DOAJ
description This study evaluated some mechanical parameters of Z250 composite resin using different light-curing methods. Ten specimens were prepared for each mechanical test group with different dimensions according to the test. Light-curing was performed by: a). continuous light (800mW/cm²-40s); b). exponential light (0-800mW/cm²-40s); c). intermittent light (2s-600mW/cm²; 2s without light-80s); d). stepped light (10s-150mW/cm²; 30s-650mW/cm²); e). PAC (1320mW/cm²-3s); f). LED (350mW/cm²-40s). After 24 &plusmn; 1 h, the specimens were loaded at a crosshead speed of 0.5 mm/min until fracture. The mechanical properties were calculated and analyzed by ANOVA and Tukey test (5%). The results showed that the highest compressive strength values were found for the continuous, exponential, intermittent and stepped light methods, whereas PAC and LED obtained the lowest values. LED, stepped light, PAC, exponential and continuous light presented the highest values for diametral tensile strength. The intermittent light showed the lowest value, which was significantly lower than the value obtained for LED only. Flexural strength results were not significantly different between all light-curing methods. Finally, the highest modulus of elasticity values were obtained for LED, exponential, continuous and intermittent light, whereas PAC and stepped light showed the lowest values. The mechanical properties were affected by light-curing methods employed.<br>Este estudo avaliou algumas propriedades mecânicas da resina composta Z250 usando diferentes métodos de fotoativação. Dez amostras foram preparadas para cada grupo, com diferentes dimensões de acordo com o ensaio. Os métodos de fotoativação foram: a) luz contínua (800mW/cm²-40s); b) luz exponencial (0-800mW/cm²-40s); c) luz intermitente (2s-600mW/cm²; 2s sem luz-80s); d) dupla intensidade (10s-150mW/cm²; 30s-650mW/cm²); e) PAC (1320mW/cm²-3s); f) LED (350mW/cm²-40s). Após 24 &plusmn; 1 h, as amostras foram carregadas até fraturar (v=0,5 mm/min.). As propriedades mecânicas foram calculadas e os dados analisados estatisticamente (ANOVA e teste de Tukey 5%). Os resultados mostraram que, para resistência à compressão, os maiores valores foram encontrados com os métodos luz contínua, intermitente, exponencial e dupla intensidade, enquanto que PAC e LED obtiveram os menores valores. Os métodos LED, PAC, luz contínua, exponencial e dupla intensidade, mostraram os maiores valores para resistência à tração diametral, enquanto luz intermitente mostrou os menores valores, que diferiram apenas do LED. Para a resistência flexural, não houve diferença entre os métodos. Já, para o módulo de elasticidade, os maiores valores foram obtidos com LED, luz exponencial, contínua e intermitente, enquanto que PAC e dupla intensidade mostraram os menores valores. As propriedades mecânicas podem ser afetadas pelo método de fotativação utilizado.
first_indexed 2024-12-22T09:26:11Z
format Article
id doaj.art-20480827c94b4876bc7aa182a30f5035
institution Directory Open Access Journal
issn 1678-7757
1678-7765
language English
last_indexed 2024-12-22T09:26:11Z
publishDate 2005-12-01
publisher University of São Paulo
record_format Article
series Journal of Applied Oral Science
spelling doaj.art-20480827c94b4876bc7aa182a30f50352022-12-21T18:31:04ZengUniversity of São PauloJournal of Applied Oral Science1678-77571678-77652005-12-0113439339810.1590/S1678-77572005000400015Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodosAndresa Carla ObiciMário Alexandre Coelho SinhoretiLourenço Correr-SobrinhoMário Fernando de GóesSimonides ConsaniThis study evaluated some mechanical parameters of Z250 composite resin using different light-curing methods. Ten specimens were prepared for each mechanical test group with different dimensions according to the test. Light-curing was performed by: a). continuous light (800mW/cm²-40s); b). exponential light (0-800mW/cm²-40s); c). intermittent light (2s-600mW/cm²; 2s without light-80s); d). stepped light (10s-150mW/cm²; 30s-650mW/cm²); e). PAC (1320mW/cm²-3s); f). LED (350mW/cm²-40s). After 24 &plusmn; 1 h, the specimens were loaded at a crosshead speed of 0.5 mm/min until fracture. The mechanical properties were calculated and analyzed by ANOVA and Tukey test (5%). The results showed that the highest compressive strength values were found for the continuous, exponential, intermittent and stepped light methods, whereas PAC and LED obtained the lowest values. LED, stepped light, PAC, exponential and continuous light presented the highest values for diametral tensile strength. The intermittent light showed the lowest value, which was significantly lower than the value obtained for LED only. Flexural strength results were not significantly different between all light-curing methods. Finally, the highest modulus of elasticity values were obtained for LED, exponential, continuous and intermittent light, whereas PAC and stepped light showed the lowest values. The mechanical properties were affected by light-curing methods employed.<br>Este estudo avaliou algumas propriedades mecânicas da resina composta Z250 usando diferentes métodos de fotoativação. Dez amostras foram preparadas para cada grupo, com diferentes dimensões de acordo com o ensaio. Os métodos de fotoativação foram: a) luz contínua (800mW/cm²-40s); b) luz exponencial (0-800mW/cm²-40s); c) luz intermitente (2s-600mW/cm²; 2s sem luz-80s); d) dupla intensidade (10s-150mW/cm²; 30s-650mW/cm²); e) PAC (1320mW/cm²-3s); f) LED (350mW/cm²-40s). Após 24 &plusmn; 1 h, as amostras foram carregadas até fraturar (v=0,5 mm/min.). As propriedades mecânicas foram calculadas e os dados analisados estatisticamente (ANOVA e teste de Tukey 5%). Os resultados mostraram que, para resistência à compressão, os maiores valores foram encontrados com os métodos luz contínua, intermitente, exponencial e dupla intensidade, enquanto que PAC e LED obtiveram os menores valores. Os métodos LED, PAC, luz contínua, exponencial e dupla intensidade, mostraram os maiores valores para resistência à tração diametral, enquanto luz intermitente mostrou os menores valores, que diferiram apenas do LED. Para a resistência flexural, não houve diferença entre os métodos. Já, para o módulo de elasticidade, os maiores valores foram obtidos com LED, luz exponencial, contínua e intermitente, enquanto que PAC e dupla intensidade mostraram os menores valores. As propriedades mecânicas podem ser afetadas pelo método de fotativação utilizado.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572005000400015Resinas compostasFotoativaçãoResistência à compressãoTração diametralFlexãoMódulo de elasticidadeComposite resinsLight-curing methodsCompressive strengthDiametral tensile strengthFlexural strengthModulus of elasticity
spellingShingle Andresa Carla Obici
Mário Alexandre Coelho Sinhoreti
Lourenço Correr-Sobrinho
Mário Fernando de Góes
Simonides Consani
Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos
Journal of Applied Oral Science
Resinas compostas
Fotoativação
Resistência à compressão
Tração diametral
Flexão
Módulo de elasticidade
Composite resins
Light-curing methods
Compressive strength
Diametral tensile strength
Flexural strength
Modulus of elasticity
title Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos
title_full Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos
title_fullStr Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos
title_full_unstemmed Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos
title_short Evaluation of mechanical properties of Z250 composite resin light-cured by different methods Avaliação de propriedades mecânicas da resina composta Z250 fotoativada com diferentes métodos
title_sort evaluation of mechanical properties of z250 composite resin light cured by different methods avaliacao de propriedades mecanicas da resina composta z250 fotoativada com diferentes metodos
topic Resinas compostas
Fotoativação
Resistência à compressão
Tração diametral
Flexão
Módulo de elasticidade
Composite resins
Light-curing methods
Compressive strength
Diametral tensile strength
Flexural strength
Modulus of elasticity
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572005000400015
work_keys_str_mv AT andresacarlaobici evaluationofmechanicalpropertiesofz250compositeresinlightcuredbydifferentmethodsavaliacaodepropriedadesmecanicasdaresinacompostaz250fotoativadacomdiferentesmetodos
AT marioalexandrecoelhosinhoreti evaluationofmechanicalpropertiesofz250compositeresinlightcuredbydifferentmethodsavaliacaodepropriedadesmecanicasdaresinacompostaz250fotoativadacomdiferentesmetodos
AT lourencocorrersobrinho evaluationofmechanicalpropertiesofz250compositeresinlightcuredbydifferentmethodsavaliacaodepropriedadesmecanicasdaresinacompostaz250fotoativadacomdiferentesmetodos
AT mariofernandodegoes evaluationofmechanicalpropertiesofz250compositeresinlightcuredbydifferentmethodsavaliacaodepropriedadesmecanicasdaresinacompostaz250fotoativadacomdiferentesmetodos
AT simonidesconsani evaluationofmechanicalpropertiesofz250compositeresinlightcuredbydifferentmethodsavaliacaodepropriedadesmecanicasdaresinacompostaz250fotoativadacomdiferentesmetodos