Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris

Relevance. Suture fixation of dislocated IOL capsule-sac complexes to the iris is widely used at present. Violation of the correct position of the IOL affects the decrease in contrast sensitivity, the appearance of dysphotopsias and aberrations. Determining the dependence of the parameters of the IO...

Full description

Bibliographic Details
Main Authors: V. N. Nikitin, D. I. Ivanov
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2023-01-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/1984
_version_ 1797875356655419392
author V. N. Nikitin
D. I. Ivanov
author_facet V. N. Nikitin
D. I. Ivanov
author_sort V. N. Nikitin
collection DOAJ
description Relevance. Suture fixation of dislocated IOL capsule-sac complexes to the iris is widely used at present. Violation of the correct position of the IOL affects the decrease in contrast sensitivity, the appearance of dysphotopsias and aberrations. Determining the dependence of the parameters of the IOL position on the quantitative characteristics of wave front aberrations in the delayed period will allow us to consider the applied methods of surgical treatment from the position of influencing the quality of vision.Purpose: to conduct a comparative assessment of the effect of IOL tilt and decentration on aberrometry indicators in the delayed postoperative period in patients with suture fixation of the IOL capsular-bag complex to the iris.Patients and methods. The main group consisted of 46 eyes operated on in 2014–2016 for the dislocation of capsule-bag complex by suture fixation to the iris for 2 arches. Comparison group — 30 eyes with articulation without suture fixation, having high uncorrected visual acuity (0.8–1.0). According to the study design, the indicators of both groups were determined at least 5 years after the operation. All patients had spherical IOLs. The determination of the IOL position (tilt and decentration) was carried out on RTVue OCT (Optovue, USA). Aberrometry was carried out on the OPD-Scan III, a comparative assessment of the wavefront indicators was performed: the mean square error of the total wavefront (Total RMS), general internal aberrations, tilt aberrations — “tilt”, total high-order aberrations “high”, oblique ray aberrations “Coma”.Results. Indicators of the IOL position. The main group. The average value of the angle of inclination in the horizontal meridian of the IOL was 3.07 ± 0.35°, in the vertical meridian 2.35 ± 0.25°. The decentration relative to the center of the pupil was 387.0 ± 3.4 mkm in the horizontal meridian, 443.0 ± 4.3 mkm in the vertical meridian. The comparison group. The average value of the angle of inclination in the horizontal meridian of the IOL was 3.04 ± 0.35°, in the vertical meridian 1.43 ± 0.13°. The decentration relative to the center of the pupil was 190.0 ± 2.8 mkm in the horizontal meridian, 259.0 ± 3.4 mkm in the vertical meridian. Aberrometry indicators. The main group: total RMS 0.52 ± 0.04, total internal aberrations 0.96 ± 0.04, tilt aberrations — “tilt” 0.31 ± 0.02, total high-order aberrations “high” 0.29 ± 0.01, oblique ray aberrations “Coma” 0.201 ± 0.010. The comparison group: total RMS 0.29 ± 0.03, total internal aberrations 0.66 ± 0.08, tilt aberrations — ““tilt” 0.202 ± 0.02, total high-order aberrations “high” 0.19 ± 0.07, oblique ray aberrations “Coma” 0.088 ± 0.010.The differences in the compared groups were significant (p < 0.05).The calculation of the correlation coefficient, when comparing the parameters of IOL decentration and the quantitative characteristics of aberrations, revealed a weak positive dependence, which indicates a slight influence of the obtained IOL decentration parameters on both internal aberrations and the RMS integral indicator.Conclusion. Thus, a comparative assessment of the indicators of the IOL position (tilt / decentration) and the number of wave front aberrations did not reveal a significant correlation. The correct central position of the IOL reduces wavefront aberrations and ensures high quality of vision. The method of suture fixation of the capsule-bag complexes to the iris provides a high functional and qualitative result in a delayed period.
first_indexed 2024-04-10T01:46:22Z
format Article
id doaj.art-20819730db204315be0c0edb4d445bb5
institution Directory Open Access Journal
issn 1816-5095
2500-0845
language Russian
last_indexed 2024-04-10T01:46:22Z
publishDate 2023-01-01
publisher Ophthalmology Publishing Group
record_format Article
series Oftalʹmologiâ
spelling doaj.art-20819730db204315be0c0edb4d445bb52023-03-13T09:08:43ZrusOphthalmology Publishing GroupOftalʹmologiâ1816-50952500-08452023-01-0119476877310.18008/1816-5095-2022-4-768-773970Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the IrisV. N. Nikitin0D. I. Ivanov1АО «Екатеринбургский центр МНТК “Микрохирургия глаза”»АО «Екатеринбургский центр МНТК “Микрохирургия глаза”»Relevance. Suture fixation of dislocated IOL capsule-sac complexes to the iris is widely used at present. Violation of the correct position of the IOL affects the decrease in contrast sensitivity, the appearance of dysphotopsias and aberrations. Determining the dependence of the parameters of the IOL position on the quantitative characteristics of wave front aberrations in the delayed period will allow us to consider the applied methods of surgical treatment from the position of influencing the quality of vision.Purpose: to conduct a comparative assessment of the effect of IOL tilt and decentration on aberrometry indicators in the delayed postoperative period in patients with suture fixation of the IOL capsular-bag complex to the iris.Patients and methods. The main group consisted of 46 eyes operated on in 2014–2016 for the dislocation of capsule-bag complex by suture fixation to the iris for 2 arches. Comparison group — 30 eyes with articulation without suture fixation, having high uncorrected visual acuity (0.8–1.0). According to the study design, the indicators of both groups were determined at least 5 years after the operation. All patients had spherical IOLs. The determination of the IOL position (tilt and decentration) was carried out on RTVue OCT (Optovue, USA). Aberrometry was carried out on the OPD-Scan III, a comparative assessment of the wavefront indicators was performed: the mean square error of the total wavefront (Total RMS), general internal aberrations, tilt aberrations — “tilt”, total high-order aberrations “high”, oblique ray aberrations “Coma”.Results. Indicators of the IOL position. The main group. The average value of the angle of inclination in the horizontal meridian of the IOL was 3.07 ± 0.35°, in the vertical meridian 2.35 ± 0.25°. The decentration relative to the center of the pupil was 387.0 ± 3.4 mkm in the horizontal meridian, 443.0 ± 4.3 mkm in the vertical meridian. The comparison group. The average value of the angle of inclination in the horizontal meridian of the IOL was 3.04 ± 0.35°, in the vertical meridian 1.43 ± 0.13°. The decentration relative to the center of the pupil was 190.0 ± 2.8 mkm in the horizontal meridian, 259.0 ± 3.4 mkm in the vertical meridian. Aberrometry indicators. The main group: total RMS 0.52 ± 0.04, total internal aberrations 0.96 ± 0.04, tilt aberrations — “tilt” 0.31 ± 0.02, total high-order aberrations “high” 0.29 ± 0.01, oblique ray aberrations “Coma” 0.201 ± 0.010. The comparison group: total RMS 0.29 ± 0.03, total internal aberrations 0.66 ± 0.08, tilt aberrations — ““tilt” 0.202 ± 0.02, total high-order aberrations “high” 0.19 ± 0.07, oblique ray aberrations “Coma” 0.088 ± 0.010.The differences in the compared groups were significant (p < 0.05).The calculation of the correlation coefficient, when comparing the parameters of IOL decentration and the quantitative characteristics of aberrations, revealed a weak positive dependence, which indicates a slight influence of the obtained IOL decentration parameters on both internal aberrations and the RMS integral indicator.Conclusion. Thus, a comparative assessment of the indicators of the IOL position (tilt / decentration) and the number of wave front aberrations did not reveal a significant correlation. The correct central position of the IOL reduces wavefront aberrations and ensures high quality of vision. The method of suture fixation of the capsule-bag complexes to the iris provides a high functional and qualitative result in a delayed period.https://www.ophthalmojournal.com/opht/article/view/1984подшивание иол к радужкенаклон/децентрация иолконтракционный капсулярный синдромаберрометрия
spellingShingle V. N. Nikitin
D. I. Ivanov
Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris
Oftalʹmologiâ
подшивание иол к радужке
наклон/децентрация иол
контракционный капсулярный синдром
аберрометрия
title Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris
title_full Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris
title_fullStr Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris
title_full_unstemmed Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris
title_short Comparative Assessment of the Influence of the IOL Position on the Aberrometry Parameters after Suture Fixation of the IOL-Capsule Bag Complex to the Iris
title_sort comparative assessment of the influence of the iol position on the aberrometry parameters after suture fixation of the iol capsule bag complex to the iris
topic подшивание иол к радужке
наклон/децентрация иол
контракционный капсулярный синдром
аберрометрия
url https://www.ophthalmojournal.com/opht/article/view/1984
work_keys_str_mv AT vnnikitin comparativeassessmentoftheinfluenceoftheiolpositionontheaberrometryparametersaftersuturefixationoftheiolcapsulebagcomplextotheiris
AT diivanov comparativeassessmentoftheinfluenceoftheiolpositionontheaberrometryparametersaftersuturefixationoftheiolcapsulebagcomplextotheiris