Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2

In this following up paper, we present our findings by examining a pilot scale gasification column and applying nitrogen purging for samples of produced water grafted with different polyacrylamide concentrations (100 – 500 ppm). Upon applying a semi-batch, counter-current scheme for a series of expe...

Full description

Bibliographic Details
Main Authors: Salam Al Dawery, Wameath AbdulMajeed, Saada Al Shukaili, Chandramouli Thotireddy, Ibrahim Al Amri
Format: Article
Language:English
Published: Unviversity of Technology- Iraq 2022-09-01
Series:Engineering and Technology Journal
Subjects:
Online Access:https://etj.uotechnology.edu.iq/article_175487_2f59e17a67f7e6caaabe0da535e41ddb.pdf
_version_ 1797337665685684224
author Salam Al Dawery
Wameath AbdulMajeed
Saada Al Shukaili
Chandramouli Thotireddy
Ibrahim Al Amri
author_facet Salam Al Dawery
Wameath AbdulMajeed
Saada Al Shukaili
Chandramouli Thotireddy
Ibrahim Al Amri
author_sort Salam Al Dawery
collection DOAJ
description In this following up paper, we present our findings by examining a pilot scale gasification column and applying nitrogen purging for samples of produced water grafted with different polyacrylamide concentrations (100 – 500 ppm). Upon applying a semi-batch, counter-current scheme for a series of experiments on packed gas-lift column, zero ppm level of dissolved oxygen (DO) was reached within less than 1 minute of nitrogen purging from the start time applied for solutions with viscosity less than 10 mPa.s and using the inline measuring scheme. However, zero ppm DO level was not reachable when purging produced water (PW) samples grafted with fresh polyacrylamide with a viscosity higher than 10 mPa.s. Nonetheless, the residues of DO were detected by offline measuring after examining the higher viscosity samples in the shallow limit (less than 0.4 ppm DO) and reached zero ppm when applying the inline measuring scheme. Two operation mode schemes, circulation, and once-through, were applied. Upon investigating the once-through contact scheme, the adopted nitrogen purging method was effective in reaching zero ppm level in less than 2 minutes, which is an excellent result compared with other well-known treatment techniques.
first_indexed 2024-03-08T09:16:52Z
format Article
id doaj.art-208bfc2dccfb4712ac20f75f63905024
institution Directory Open Access Journal
issn 1681-6900
2412-0758
language English
last_indexed 2024-03-08T09:16:52Z
publishDate 2022-09-01
publisher Unviversity of Technology- Iraq
record_format Article
series Engineering and Technology Journal
spelling doaj.art-208bfc2dccfb4712ac20f75f639050242024-01-31T14:27:56ZengUnviversity of Technology- IraqEngineering and Technology Journal1681-69002412-07582022-09-014091260127410.30684/etj.2022.134758.1248175487Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2Salam Al Dawery0Wameath AbdulMajeed1Saada Al Shukaili2Chandramouli Thotireddy3Ibrahim Al Amri4College of Engineering University of NizwaUniversity of Nizwa College of Engineering and Architecture Department of Chemical and Petrochemical EngineeringPetroleum Development Oman; Oman - Muscat, PC 100, POB 81Petroleum Development Oman; Oman - Muscat, PC 100, POB 81Petroleum Development Oman; Oman - Muscat, PC 100, POB 81In this following up paper, we present our findings by examining a pilot scale gasification column and applying nitrogen purging for samples of produced water grafted with different polyacrylamide concentrations (100 – 500 ppm). Upon applying a semi-batch, counter-current scheme for a series of experiments on packed gas-lift column, zero ppm level of dissolved oxygen (DO) was reached within less than 1 minute of nitrogen purging from the start time applied for solutions with viscosity less than 10 mPa.s and using the inline measuring scheme. However, zero ppm DO level was not reachable when purging produced water (PW) samples grafted with fresh polyacrylamide with a viscosity higher than 10 mPa.s. Nonetheless, the residues of DO were detected by offline measuring after examining the higher viscosity samples in the shallow limit (less than 0.4 ppm DO) and reached zero ppm when applying the inline measuring scheme. Two operation mode schemes, circulation, and once-through, were applied. Upon investigating the once-through contact scheme, the adopted nitrogen purging method was effective in reaching zero ppm level in less than 2 minutes, which is an excellent result compared with other well-known treatment techniques.https://etj.uotechnology.edu.iq/article_175487_2f59e17a67f7e6caaabe0da535e41ddb.pdfproduced water treatmentdissolved oxygenn2 purginggas lift column
spellingShingle Salam Al Dawery
Wameath AbdulMajeed
Saada Al Shukaili
Chandramouli Thotireddy
Ibrahim Al Amri
Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2
Engineering and Technology Journal
produced water treatment
dissolved oxygen
n2 purging
gas lift column
title Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2
title_full Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2
title_fullStr Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2
title_full_unstemmed Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2
title_short Produced Water Deoxygenation via Nitrogen Purging Scheme– Parametric Study – Part 2
title_sort produced water deoxygenation via nitrogen purging scheme parametric study part 2
topic produced water treatment
dissolved oxygen
n2 purging
gas lift column
url https://etj.uotechnology.edu.iq/article_175487_2f59e17a67f7e6caaabe0da535e41ddb.pdf
work_keys_str_mv AT salamaldawery producedwaterdeoxygenationvianitrogenpurgingschemeparametricstudypart2
AT wameathabdulmajeed producedwaterdeoxygenationvianitrogenpurgingschemeparametricstudypart2
AT saadaalshukaili producedwaterdeoxygenationvianitrogenpurgingschemeparametricstudypart2
AT chandramoulithotireddy producedwaterdeoxygenationvianitrogenpurgingschemeparametricstudypart2
AT ibrahimalamri producedwaterdeoxygenationvianitrogenpurgingschemeparametricstudypart2