Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator

Voltage stability evaluation is needed to get the information of electrical power distribution system performance. Power flow calculation is used to determine the important parameters of power system in a steady state. An electric power system must have voltage value that does not exceed the limits...

Full description

Bibliographic Details
Main Authors: Akbar Abadi, Syafii
Format: Article
Language:English
Published: Universitas Andalas 2015-09-01
Series:Jurnal Nasional Teknik Elektro
Subjects:
Online Access:http://jnte.ft.unand.ac.id/index.php/first/article/view/145/150
_version_ 1818887323416264704
author Akbar Abadi
Syafii
author_facet Akbar Abadi
Syafii
author_sort Akbar Abadi
collection DOAJ
description Voltage stability evaluation is needed to get the information of electrical power distribution system performance. Power flow calculation is used to determine the important parameters of power system in a steady state. An electric power system must have voltage value that does not exceed the limits of tolerance and the power loss as well as small. The improvement of voltage profile can be done by using voltage-control equipments, such as capacitor banks and transformer tap. Through simulation using the PowerWorld simulator, the value and location of capacitor banks and transformers tap will obtained in order to improve system performace. Sumbar electrical system was used in this study. From the simulation results, for the initial condition of the system, there are several buses that have voltage drop with total system losses 14.4 MW. After capacitor added, the system voltage has increased significantly so that no one passed the value of tolerance and the losses in the system down to 14.1 MW. As for setting the ratio of tap transformer, voltage system did not change so much, except on the secondary side of the transformer bus arranged with system losses almost the same that equal to 14.4 MW. For the case of the addition of the capacitor and transformer tap settings in the same time, the voltage drop no longer exceeds 5% and the total system losses decreased to 13.9 MW.
first_indexed 2024-12-19T16:35:24Z
format Article
id doaj.art-211b0a50e12747a3a60cadd625b034e4
institution Directory Open Access Journal
issn 2302-2949
2407-7267
language English
last_indexed 2024-12-19T16:35:24Z
publishDate 2015-09-01
publisher Universitas Andalas
record_format Article
series Jurnal Nasional Teknik Elektro
spelling doaj.art-211b0a50e12747a3a60cadd625b034e42022-12-21T20:13:59ZengUniversitas AndalasJurnal Nasional Teknik Elektro2302-29492407-72672015-09-0142158164Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap TransformatorAkbar Abadi 0Syafii1Mahasiswa Program Studi S2 Teknik Elektro, Fakultas Teknik, Universitas AndalasJurusan Teknik Elektro, Fakultas Teknik, Universitas AndalasVoltage stability evaluation is needed to get the information of electrical power distribution system performance. Power flow calculation is used to determine the important parameters of power system in a steady state. An electric power system must have voltage value that does not exceed the limits of tolerance and the power loss as well as small. The improvement of voltage profile can be done by using voltage-control equipments, such as capacitor banks and transformer tap. Through simulation using the PowerWorld simulator, the value and location of capacitor banks and transformers tap will obtained in order to improve system performace. Sumbar electrical system was used in this study. From the simulation results, for the initial condition of the system, there are several buses that have voltage drop with total system losses 14.4 MW. After capacitor added, the system voltage has increased significantly so that no one passed the value of tolerance and the losses in the system down to 14.1 MW. As for setting the ratio of tap transformer, voltage system did not change so much, except on the secondary side of the transformer bus arranged with system losses almost the same that equal to 14.4 MW. For the case of the addition of the capacitor and transformer tap settings in the same time, the voltage drop no longer exceeds 5% and the total system losses decreased to 13.9 MW.http://jnte.ft.unand.ac.id/index.php/first/article/view/145/150Voltage stabilityCapacitor bankTap transformatorVoltage dropSystem losses
spellingShingle Akbar Abadi
Syafii
Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator
Jurnal Nasional Teknik Elektro
Voltage stability
Capacitor bank
Tap transformator
Voltage drop
System losses
title Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator
title_full Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator
title_fullStr Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator
title_full_unstemmed Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator
title_short Analisa Perbaikan Profil Tegangan Sistem Tenaga Listrik Sumbar Menggunakan Kapasitor Bank dan Tap Transformator
title_sort analisa perbaikan profil tegangan sistem tenaga listrik sumbar menggunakan kapasitor bank dan tap transformator
topic Voltage stability
Capacitor bank
Tap transformator
Voltage drop
System losses
url http://jnte.ft.unand.ac.id/index.php/first/article/view/145/150
work_keys_str_mv AT akbarabadi analisaperbaikanprofiltegangansistemtenagalistriksumbarmenggunakankapasitorbankdantaptransformator
AT syafii analisaperbaikanprofiltegangansistemtenagalistriksumbarmenggunakankapasitorbankdantaptransformator