Setup uncertainties and appropriate setup margins in the head-tilted supine position of whole-brain radiotherapy (WBRT).

Various applications of head-tilting techniques in whole-brain radiotherapy (WBRT) have been introduced. However, a study on the setup uncertainties and margins in head-tilting techniques has not been reported. This study evaluated the setup uncertainties and determined the appropriate planning targ...

Mô tả đầy đủ

Chi tiết về thư mục
Những tác giả chính: Jae Won Park, Ji Woon Yea, Jaehyeon Park, Se An Oh
Định dạng: Bài viết
Ngôn ngữ:English
Được phát hành: Public Library of Science (PLoS) 2022-01-01
Loạt:PLoS ONE
Truy cập trực tuyến:https://doi.org/10.1371/journal.pone.0271077
Miêu tả
Tóm tắt:Various applications of head-tilting techniques in whole-brain radiotherapy (WBRT) have been introduced. However, a study on the setup uncertainties and margins in head-tilting techniques has not been reported. This study evaluated the setup uncertainties and determined the appropriate planning target volume (PTV) margins for patients treated in the head-tilted supine (ht-SP) and conventional supine position (c-SP) in WBRT. Thirty patients who received WBRT at our institution between October 2020 and May 2021 in the c-SP and ht-SP were investigated. The DUON head mask (60124, Orfit Industries, Wijnegem, Belgium) was used in the c-SP, and a thermoplastic U-Frame Mask (R420U, Klarity Medical & Equipment Co. Ltd., Lan Yu, China) was used in the ht-SP. Daily setup verification using planning computed tomography (CT) and cone-beam CT was corrected for translational (lateral, longitudinal, and vertical) and rotational (yaw) errors. In the c-SP, the means of systematic errors were -0.80, 0.79, and 0.37 mm and random errors were 0.27, 0.54, and 0.39 mm in the lateral, longitudinal, and vertical translational dimensions, respectively. Whereas, for the ht-SP, the means of systematic errors were -0.07, 0.73, and -0.63 mm, and random errors were 0.75, 1.39, 1.02 mm in the lateral, longitudinal, and vertical translational dimensions, respectively. The PTV margins were calculated using Stroom et al.'s [2Σ+0.7σ] and van Herk et al.'s recipe [2.5Σ+0.7σ]. Appropriate PTV margins with van Herk et al.'s recipe in WBRT were <2 mm and 1.5° in the c-SP and <3 mm and 2° in the ht-SP in the translational and rotational directions, respectively. Although the head tilt in the supine position requires more margin, it can be applied as a sufficiently stable and effective position in radiotherapy.
số ISSN:1932-6203