Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom
A breast phantom developed at the Supelec Institute was interrogated to study its suitability for microwave tomography measurements. A microwave measurement system based on 16 monopole antennas and a vector network analyzer was used to study how the S-parameters are influenced by insertion of the ph...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2018-09-01
|
Series: | Diagnostics |
Subjects: | |
Online Access: | http://www.mdpi.com/2075-4418/8/3/61 |
_version_ | 1798006869728428032 |
---|---|
author | Tomas Rydholm Andreas Fhager Mikael Persson Shireen D. Geimer Paul M. Meaney |
author_facet | Tomas Rydholm Andreas Fhager Mikael Persson Shireen D. Geimer Paul M. Meaney |
author_sort | Tomas Rydholm |
collection | DOAJ |
description | A breast phantom developed at the Supelec Institute was interrogated to study its suitability for microwave tomography measurements. A microwave measurement system based on 16 monopole antennas and a vector network analyzer was used to study how the S-parameters are influenced by insertion of the phantom. The phantom is a 3D-printed structure consisting of plastic shells that can be filled with tissue mimicking liquids. The phantom was filled with different liquids and tested with the measurement system to determine whether the plastic has any effects on the recovered images or not. Measurements of the phantom when it is filled with the same liquid as the surrounding coupling medium are of particular interest. In this case, the phantom plastic has a substantial effects on the measurements which ultimately detracts from the desired images. |
first_indexed | 2024-04-11T13:01:19Z |
format | Article |
id | doaj.art-21dd211e28014ed6a4df4c28b2bada24 |
institution | Directory Open Access Journal |
issn | 2075-4418 |
language | English |
last_indexed | 2024-04-11T13:01:19Z |
publishDate | 2018-09-01 |
publisher | MDPI AG |
record_format | Article |
series | Diagnostics |
spelling | doaj.art-21dd211e28014ed6a4df4c28b2bada242022-12-22T04:22:55ZengMDPI AGDiagnostics2075-44182018-09-01836110.3390/diagnostics8030061diagnostics8030061Effects of the Plastic of the Realistic GeePS-L2S-Breast PhantomTomas Rydholm0Andreas Fhager1Mikael Persson2Shireen D. Geimer3Paul M. Meaney4Department of Electrical Engineering, Chalmers University of Technology, 41258 Gothenburg, SwedenDepartment of Electrical Engineering, Chalmers University of Technology, 41258 Gothenburg, SwedenDepartment of Electrical Engineering, Chalmers University of Technology, 41258 Gothenburg, SwedenThayer’s School of Engineering, Dartmouth College, Hanover, NH 03755, USADepartment of Electrical Engineering, Chalmers University of Technology, 41258 Gothenburg, SwedenA breast phantom developed at the Supelec Institute was interrogated to study its suitability for microwave tomography measurements. A microwave measurement system based on 16 monopole antennas and a vector network analyzer was used to study how the S-parameters are influenced by insertion of the phantom. The phantom is a 3D-printed structure consisting of plastic shells that can be filled with tissue mimicking liquids. The phantom was filled with different liquids and tested with the measurement system to determine whether the plastic has any effects on the recovered images or not. Measurements of the phantom when it is filled with the same liquid as the surrounding coupling medium are of particular interest. In this case, the phantom plastic has a substantial effects on the measurements which ultimately detracts from the desired images.http://www.mdpi.com/2075-4418/8/3/61breast cancermicrowave imagingphantomtomography |
spellingShingle | Tomas Rydholm Andreas Fhager Mikael Persson Shireen D. Geimer Paul M. Meaney Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom Diagnostics breast cancer microwave imaging phantom tomography |
title | Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom |
title_full | Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom |
title_fullStr | Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom |
title_full_unstemmed | Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom |
title_short | Effects of the Plastic of the Realistic GeePS-L2S-Breast Phantom |
title_sort | effects of the plastic of the realistic geeps l2s breast phantom |
topic | breast cancer microwave imaging phantom tomography |
url | http://www.mdpi.com/2075-4418/8/3/61 |
work_keys_str_mv | AT tomasrydholm effectsoftheplasticoftherealisticgeepsl2sbreastphantom AT andreasfhager effectsoftheplasticoftherealisticgeepsl2sbreastphantom AT mikaelpersson effectsoftheplasticoftherealisticgeepsl2sbreastphantom AT shireendgeimer effectsoftheplasticoftherealisticgeepsl2sbreastphantom AT paulmmeaney effectsoftheplasticoftherealisticgeepsl2sbreastphantom |