Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid
Circuit breaker (CB) and fault current limiter (FCL) are two major fault protection devices used in mesh-type DC microgrids. This paper proposes the parameters selection method to obtain a reliable and economic configuration scheme of CBs and FCLs applied in mesh-type DC microgrid. The breaking time...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2021-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/9360536/ |
_version_ | 1818609131546738688 |
---|---|
author | Liang Kong Heng Nian |
author_facet | Liang Kong Heng Nian |
author_sort | Liang Kong |
collection | DOAJ |
description | Circuit breaker (CB) and fault current limiter (FCL) are two major fault protection devices used in mesh-type DC microgrids. This paper proposes the parameters selection method to obtain a reliable and economic configuration scheme of CBs and FCLs applied in mesh-type DC microgrid. The breaking time of CB, the nominal breaking current of CB and the inductance of FCL are selected as three optimization parameters in an evaluation model. Since the reliability of fault protection scheme depends on whether the nominal breaking current of the CB is greater than the line current at the breaking moment of CB, it is necessary to accurately calculate the post-fault line current. Based on this, an accurate transient DC microgrid model is presented in this paper. And then, an improved non-dominated sorting genetic algorithm II (NSGA-II) is used to configure the parameters of CBs and FCLs quickly. Besides, a case study on six-terminal DC microgrid test system shows that the proposed method can obtain accurate post-fault line current and can achieve the parameters selection of CBs and FCLs. |
first_indexed | 2024-12-16T14:53:40Z |
format | Article |
id | doaj.art-2217c6b8e47842189b45558ba18aa61c |
institution | Directory Open Access Journal |
issn | 2169-3536 |
language | English |
last_indexed | 2024-12-16T14:53:40Z |
publishDate | 2021-01-01 |
publisher | IEEE |
record_format | Article |
series | IEEE Access |
spelling | doaj.art-2217c6b8e47842189b45558ba18aa61c2022-12-21T22:27:31ZengIEEEIEEE Access2169-35362021-01-019355143552310.1109/ACCESS.2021.30611179360536Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC MicrogridLiang Kong0https://orcid.org/0000-0002-1186-6251Heng Nian1https://orcid.org/0000-0003-4816-084XCollege of Electrical Engineering, Zhejiang University, Hangzhou, ChinaCollege of Electrical Engineering, Zhejiang University, Hangzhou, ChinaCircuit breaker (CB) and fault current limiter (FCL) are two major fault protection devices used in mesh-type DC microgrids. This paper proposes the parameters selection method to obtain a reliable and economic configuration scheme of CBs and FCLs applied in mesh-type DC microgrid. The breaking time of CB, the nominal breaking current of CB and the inductance of FCL are selected as three optimization parameters in an evaluation model. Since the reliability of fault protection scheme depends on whether the nominal breaking current of the CB is greater than the line current at the breaking moment of CB, it is necessary to accurately calculate the post-fault line current. Based on this, an accurate transient DC microgrid model is presented in this paper. And then, an improved non-dominated sorting genetic algorithm II (NSGA-II) is used to configure the parameters of CBs and FCLs quickly. Besides, a case study on six-terminal DC microgrid test system shows that the proposed method can obtain accurate post-fault line current and can achieve the parameters selection of CBs and FCLs.https://ieeexplore.ieee.org/document/9360536/Mesh-type DC microgridDC faultcircuit breakerfault current limiterparameters selection |
spellingShingle | Liang Kong Heng Nian Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid IEEE Access Mesh-type DC microgrid DC fault circuit breaker fault current limiter parameters selection |
title | Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid |
title_full | Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid |
title_fullStr | Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid |
title_full_unstemmed | Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid |
title_short | Parameters Selection Method of Circuit Breaker and Fault Current Limiter in Mesh-Type DC Microgrid |
title_sort | parameters selection method of circuit breaker and fault current limiter in mesh type dc microgrid |
topic | Mesh-type DC microgrid DC fault circuit breaker fault current limiter parameters selection |
url | https://ieeexplore.ieee.org/document/9360536/ |
work_keys_str_mv | AT liangkong parametersselectionmethodofcircuitbreakerandfaultcurrentlimiterinmeshtypedcmicrogrid AT hengnian parametersselectionmethodofcircuitbreakerandfaultcurrentlimiterinmeshtypedcmicrogrid |